Choice of a Suitable Dosimeter for Photon Percentage Depth Dose Measurements in Flattening Filter-Free Beams

The International Atomic Energy Agency Technical Reports Series-398 code of practice for dosimetry recommends measuring photon percentage depth dose (PDD) curves with parallel-plate chambers. This code of practice was published before flattening filter-free (FFF) beams were widely used in clinical l...

Descripción completa

Detalles Bibliográficos
Autores principales: Vargas Castrillón, Silvia, Cutanda Henríquez, Francisco
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5618460/
https://www.ncbi.nlm.nih.gov/pubmed/28974859
http://dx.doi.org/10.4103/jmp.JMP_11_17
_version_ 1783267191051780096
author Vargas Castrillón, Silvia
Cutanda Henríquez, Francisco
author_facet Vargas Castrillón, Silvia
Cutanda Henríquez, Francisco
author_sort Vargas Castrillón, Silvia
collection PubMed
description The International Atomic Energy Agency Technical Reports Series-398 code of practice for dosimetry recommends measuring photon percentage depth dose (PDD) curves with parallel-plate chambers. This code of practice was published before flattening filter-free (FFF) beams were widely used in clinical linear accelerators. The choice of detector for PDD measurements needs to be reassessed for FFF beams given the physical differences between FFF beams and flattened ones. The present study compares PDD curves for FFF beams of nominal energies 6 MV, 6 FFF, 10 MV, and 10 FFF from a Varian TrueBeam linear accelerator (Varian Medical Systems, Palo Alto, USA) acquired with Scanditronix photon diodes, two scanning type chambers (both PTW 31010 Semiflex), two small volume chambers (Wellhofer CC04 and PTW 31016 PinPoint 3D), PTW 34001 Roos, Scanditronix Roos, and NACP 02 parallel-plate chambers. Results show that parallel-plate ion chambers can be used for photon PDD measurements, although for better accuracy, recombination effects should be taken into account.
format Online
Article
Text
id pubmed-5618460
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-56184602017-10-03 Choice of a Suitable Dosimeter for Photon Percentage Depth Dose Measurements in Flattening Filter-Free Beams Vargas Castrillón, Silvia Cutanda Henríquez, Francisco J Med Phys Technical Note The International Atomic Energy Agency Technical Reports Series-398 code of practice for dosimetry recommends measuring photon percentage depth dose (PDD) curves with parallel-plate chambers. This code of practice was published before flattening filter-free (FFF) beams were widely used in clinical linear accelerators. The choice of detector for PDD measurements needs to be reassessed for FFF beams given the physical differences between FFF beams and flattened ones. The present study compares PDD curves for FFF beams of nominal energies 6 MV, 6 FFF, 10 MV, and 10 FFF from a Varian TrueBeam linear accelerator (Varian Medical Systems, Palo Alto, USA) acquired with Scanditronix photon diodes, two scanning type chambers (both PTW 31010 Semiflex), two small volume chambers (Wellhofer CC04 and PTW 31016 PinPoint 3D), PTW 34001 Roos, Scanditronix Roos, and NACP 02 parallel-plate chambers. Results show that parallel-plate ion chambers can be used for photon PDD measurements, although for better accuracy, recombination effects should be taken into account. Medknow Publications & Media Pvt Ltd 2017 /pmc/articles/PMC5618460/ /pubmed/28974859 http://dx.doi.org/10.4103/jmp.JMP_11_17 Text en Copyright: © 2017 Journal of Medical Physics http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Technical Note
Vargas Castrillón, Silvia
Cutanda Henríquez, Francisco
Choice of a Suitable Dosimeter for Photon Percentage Depth Dose Measurements in Flattening Filter-Free Beams
title Choice of a Suitable Dosimeter for Photon Percentage Depth Dose Measurements in Flattening Filter-Free Beams
title_full Choice of a Suitable Dosimeter for Photon Percentage Depth Dose Measurements in Flattening Filter-Free Beams
title_fullStr Choice of a Suitable Dosimeter for Photon Percentage Depth Dose Measurements in Flattening Filter-Free Beams
title_full_unstemmed Choice of a Suitable Dosimeter for Photon Percentage Depth Dose Measurements in Flattening Filter-Free Beams
title_short Choice of a Suitable Dosimeter for Photon Percentage Depth Dose Measurements in Flattening Filter-Free Beams
title_sort choice of a suitable dosimeter for photon percentage depth dose measurements in flattening filter-free beams
topic Technical Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5618460/
https://www.ncbi.nlm.nih.gov/pubmed/28974859
http://dx.doi.org/10.4103/jmp.JMP_11_17
work_keys_str_mv AT vargascastrillonsilvia choiceofasuitabledosimeterforphotonpercentagedepthdosemeasurementsinflatteningfilterfreebeams
AT cutandahenriquezfrancisco choiceofasuitabledosimeterforphotonpercentagedepthdosemeasurementsinflatteningfilterfreebeams