Cargando…

Diagnostic use of neuro-spect quantified with (99m)Tc-ECD a model based on normal data

OBJECTIVE: The purpose of the present study was to prospectively quantify the normal limits of brain perfusion using specific software in a group of asymptomatic young volunteers submitted to single-photon emission tomography (SPECT) with (99m)Tc-ethyl cysteinate dimer ((99m)Tc-ECD). METHODS: We use...

Descripción completa

Detalles Bibliográficos
Autores principales: Marroni, Belmonte Juarez, Marroni, Sabine Possa, Mayer, Caroline Muller, Braga, Betina R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Associação de Neurologia Cognitiva e do Comportamento 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5619504/
https://www.ncbi.nlm.nih.gov/pubmed/29213867
http://dx.doi.org/10.1590/S1980-57642013DN74000010
_version_ 1783267419864694784
author Marroni, Belmonte Juarez
Marroni, Sabine Possa
Mayer, Caroline Muller
Braga, Betina R.
author_facet Marroni, Belmonte Juarez
Marroni, Sabine Possa
Mayer, Caroline Muller
Braga, Betina R.
author_sort Marroni, Belmonte Juarez
collection PubMed
description OBJECTIVE: The purpose of the present study was to prospectively quantify the normal limits of brain perfusion using specific software in a group of asymptomatic young volunteers submitted to single-photon emission tomography (SPECT) with (99m)Tc-ethyl cysteinate dimer ((99m)Tc-ECD). METHODS: We used 15 MBq/kg of intravenous (99m)Tc-ECD in 30 healthy volunteers submitted to brief neuropsychological tests and a clinical questionnaire. These data were normalized relative to the cerebellum (Group 1) and to the brain cortex (Group 2). Statistical analysis was performed with Student's t-test. The average radioactivity was 6.5 million counts/study. RESULTS: The normalized (Group I) revealed an average value of 78.03%, with standard deviation (SD) of 4.07. Two volunteers in this group had slightly greater than two standard deviations from the mean. When we used (Group II), the average value was 71.01%, with a SD of 4.66. We observed a difference between groups of 9% (P<0.001). CONCLUSION: The present study suggests normal cortical perfusional values for a group of young asymptomatic volunteers, utilizing (99m)Tc-ECD. This allows further quantification of neuro-SPECT data, specifically comparisons across patient populations. Furthermore, this method represents a new tool that can be used to further explore the field of neuroimaging, particularly neuropsychiatry.
format Online
Article
Text
id pubmed-5619504
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Associação de Neurologia Cognitiva e do Comportamento
record_format MEDLINE/PubMed
spelling pubmed-56195042017-12-06 Diagnostic use of neuro-spect quantified with (99m)Tc-ECD a model based on normal data Marroni, Belmonte Juarez Marroni, Sabine Possa Mayer, Caroline Muller Braga, Betina R. Dement Neuropsychol Original Articles OBJECTIVE: The purpose of the present study was to prospectively quantify the normal limits of brain perfusion using specific software in a group of asymptomatic young volunteers submitted to single-photon emission tomography (SPECT) with (99m)Tc-ethyl cysteinate dimer ((99m)Tc-ECD). METHODS: We used 15 MBq/kg of intravenous (99m)Tc-ECD in 30 healthy volunteers submitted to brief neuropsychological tests and a clinical questionnaire. These data were normalized relative to the cerebellum (Group 1) and to the brain cortex (Group 2). Statistical analysis was performed with Student's t-test. The average radioactivity was 6.5 million counts/study. RESULTS: The normalized (Group I) revealed an average value of 78.03%, with standard deviation (SD) of 4.07. Two volunteers in this group had slightly greater than two standard deviations from the mean. When we used (Group II), the average value was 71.01%, with a SD of 4.66. We observed a difference between groups of 9% (P<0.001). CONCLUSION: The present study suggests normal cortical perfusional values for a group of young asymptomatic volunteers, utilizing (99m)Tc-ECD. This allows further quantification of neuro-SPECT data, specifically comparisons across patient populations. Furthermore, this method represents a new tool that can be used to further explore the field of neuroimaging, particularly neuropsychiatry. Associação de Neurologia Cognitiva e do Comportamento 2013 /pmc/articles/PMC5619504/ /pubmed/29213867 http://dx.doi.org/10.1590/S1980-57642013DN74000010 Text en http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Articles
Marroni, Belmonte Juarez
Marroni, Sabine Possa
Mayer, Caroline Muller
Braga, Betina R.
Diagnostic use of neuro-spect quantified with (99m)Tc-ECD a model based on normal data
title Diagnostic use of neuro-spect quantified with (99m)Tc-ECD a model based on normal data
title_full Diagnostic use of neuro-spect quantified with (99m)Tc-ECD a model based on normal data
title_fullStr Diagnostic use of neuro-spect quantified with (99m)Tc-ECD a model based on normal data
title_full_unstemmed Diagnostic use of neuro-spect quantified with (99m)Tc-ECD a model based on normal data
title_short Diagnostic use of neuro-spect quantified with (99m)Tc-ECD a model based on normal data
title_sort diagnostic use of neuro-spect quantified with (99m)tc-ecd a model based on normal data
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5619504/
https://www.ncbi.nlm.nih.gov/pubmed/29213867
http://dx.doi.org/10.1590/S1980-57642013DN74000010
work_keys_str_mv AT marronibelmontejuarez diagnosticuseofneurospectquantifiedwith99mtcecdamodelbasedonnormaldata
AT marronisabinepossa diagnosticuseofneurospectquantifiedwith99mtcecdamodelbasedonnormaldata
AT mayercarolinemuller diagnosticuseofneurospectquantifiedwith99mtcecdamodelbasedonnormaldata
AT bragabetinar diagnosticuseofneurospectquantifiedwith99mtcecdamodelbasedonnormaldata