Cargando…
Electrical Detection of Pneumococcus through the Nanoparticle Decoration Method
A simple method of nanoparticle decoration can be used in the detection of pneumococcus. After the pneumococcal bacteria were captured by an antibody (pneumococcal C-polysaccharide (PnC) antibody) between the interdigitated electrodes, the gold nanoparticles conjugated with the PnC antibodies were l...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5621115/ https://www.ncbi.nlm.nih.gov/pubmed/28869504 http://dx.doi.org/10.3390/s17092012 |
_version_ | 1783267689490284544 |
---|---|
author | Pyo, Hannah Lee, Cho Yeon Kim, Daehee Kim, Gyuhee Lee, Sangho Yun, Wan Soo |
author_facet | Pyo, Hannah Lee, Cho Yeon Kim, Daehee Kim, Gyuhee Lee, Sangho Yun, Wan Soo |
author_sort | Pyo, Hannah |
collection | PubMed |
description | A simple method of nanoparticle decoration can be used in the detection of pneumococcus. After the pneumococcal bacteria were captured by an antibody (pneumococcal C-polysaccharide (PnC) antibody) between the interdigitated electrodes, the gold nanoparticles conjugated with the PnC antibodies were let to bind onto an outer membrane of the bacteria. Upon successfully dense decoration, the bacteria surface will become conductive owing to the metal nanoparticles, and a distinctive conductance change between the electrodes can be observed. Since this success ratio, or the probability of the conductance change, reflects the concentration of the analyte, a number of repeated measurements can be used in the quantification of the bacteria. In this way, we have successfully detected S. pneumoniae in the range of 10–10(8) CFU/mL. The limit of detection in this work is lower than that in the commercial detection kit. We hope that the nanoparticle decoration method will play a role in the facile detection of various bacteria. |
format | Online Article Text |
id | pubmed-5621115 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-56211152017-10-03 Electrical Detection of Pneumococcus through the Nanoparticle Decoration Method Pyo, Hannah Lee, Cho Yeon Kim, Daehee Kim, Gyuhee Lee, Sangho Yun, Wan Soo Sensors (Basel) Communication A simple method of nanoparticle decoration can be used in the detection of pneumococcus. After the pneumococcal bacteria were captured by an antibody (pneumococcal C-polysaccharide (PnC) antibody) between the interdigitated electrodes, the gold nanoparticles conjugated with the PnC antibodies were let to bind onto an outer membrane of the bacteria. Upon successfully dense decoration, the bacteria surface will become conductive owing to the metal nanoparticles, and a distinctive conductance change between the electrodes can be observed. Since this success ratio, or the probability of the conductance change, reflects the concentration of the analyte, a number of repeated measurements can be used in the quantification of the bacteria. In this way, we have successfully detected S. pneumoniae in the range of 10–10(8) CFU/mL. The limit of detection in this work is lower than that in the commercial detection kit. We hope that the nanoparticle decoration method will play a role in the facile detection of various bacteria. MDPI 2017-09-02 /pmc/articles/PMC5621115/ /pubmed/28869504 http://dx.doi.org/10.3390/s17092012 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Communication Pyo, Hannah Lee, Cho Yeon Kim, Daehee Kim, Gyuhee Lee, Sangho Yun, Wan Soo Electrical Detection of Pneumococcus through the Nanoparticle Decoration Method |
title | Electrical Detection of Pneumococcus through the Nanoparticle Decoration Method |
title_full | Electrical Detection of Pneumococcus through the Nanoparticle Decoration Method |
title_fullStr | Electrical Detection of Pneumococcus through the Nanoparticle Decoration Method |
title_full_unstemmed | Electrical Detection of Pneumococcus through the Nanoparticle Decoration Method |
title_short | Electrical Detection of Pneumococcus through the Nanoparticle Decoration Method |
title_sort | electrical detection of pneumococcus through the nanoparticle decoration method |
topic | Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5621115/ https://www.ncbi.nlm.nih.gov/pubmed/28869504 http://dx.doi.org/10.3390/s17092012 |
work_keys_str_mv | AT pyohannah electricaldetectionofpneumococcusthroughthenanoparticledecorationmethod AT leechoyeon electricaldetectionofpneumococcusthroughthenanoparticledecorationmethod AT kimdaehee electricaldetectionofpneumococcusthroughthenanoparticledecorationmethod AT kimgyuhee electricaldetectionofpneumococcusthroughthenanoparticledecorationmethod AT leesangho electricaldetectionofpneumococcusthroughthenanoparticledecorationmethod AT yunwansoo electricaldetectionofpneumococcusthroughthenanoparticledecorationmethod |