Cargando…
Geometric Calibration and Accuracy Verification of the GF-3 Satellite
The GF-3 satellite is the first multi-polarization synthetic aperture radar (SAR) imaging satellite in China, which operates in the C band with a resolution of 1 m. Although the SAR satellite system was geometrically calibrated during the in-orbit commissioning phase, there are still some system err...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5621162/ https://www.ncbi.nlm.nih.gov/pubmed/28850055 http://dx.doi.org/10.3390/s17091977 |
_version_ | 1783267699749552128 |
---|---|
author | Zhao, Ruishan Zhang, Guo Deng, Mingjun Xu, Kai Guo, Fengcheng |
author_facet | Zhao, Ruishan Zhang, Guo Deng, Mingjun Xu, Kai Guo, Fengcheng |
author_sort | Zhao, Ruishan |
collection | PubMed |
description | The GF-3 satellite is the first multi-polarization synthetic aperture radar (SAR) imaging satellite in China, which operates in the C band with a resolution of 1 m. Although the SAR satellite system was geometrically calibrated during the in-orbit commissioning phase, there are still some system errors that affect its geometric positioning accuracy. In this study, these errors are classified into three categories: fixed system error, time-varying system error, and random error. Using a multimode hybrid geometric calibration of spaceborne SAR, and considering the atmospheric propagation delay, all system errors can be effectively corrected through high-precision ground control points and global atmospheric reference data. The geometric calibration experiments and accuracy evaluation for the GF-3 satellite are performed using ground control data from several regions. The experimental results show that the residual system errors of the GF-3 SAR satellite have been effectively eliminated, and the geometric positioning accuracy can be better than 3 m. |
format | Online Article Text |
id | pubmed-5621162 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-56211622017-10-03 Geometric Calibration and Accuracy Verification of the GF-3 Satellite Zhao, Ruishan Zhang, Guo Deng, Mingjun Xu, Kai Guo, Fengcheng Sensors (Basel) Article The GF-3 satellite is the first multi-polarization synthetic aperture radar (SAR) imaging satellite in China, which operates in the C band with a resolution of 1 m. Although the SAR satellite system was geometrically calibrated during the in-orbit commissioning phase, there are still some system errors that affect its geometric positioning accuracy. In this study, these errors are classified into three categories: fixed system error, time-varying system error, and random error. Using a multimode hybrid geometric calibration of spaceborne SAR, and considering the atmospheric propagation delay, all system errors can be effectively corrected through high-precision ground control points and global atmospheric reference data. The geometric calibration experiments and accuracy evaluation for the GF-3 satellite are performed using ground control data from several regions. The experimental results show that the residual system errors of the GF-3 SAR satellite have been effectively eliminated, and the geometric positioning accuracy can be better than 3 m. MDPI 2017-08-29 /pmc/articles/PMC5621162/ /pubmed/28850055 http://dx.doi.org/10.3390/s17091977 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Zhao, Ruishan Zhang, Guo Deng, Mingjun Xu, Kai Guo, Fengcheng Geometric Calibration and Accuracy Verification of the GF-3 Satellite |
title | Geometric Calibration and Accuracy Verification of the GF-3 Satellite |
title_full | Geometric Calibration and Accuracy Verification of the GF-3 Satellite |
title_fullStr | Geometric Calibration and Accuracy Verification of the GF-3 Satellite |
title_full_unstemmed | Geometric Calibration and Accuracy Verification of the GF-3 Satellite |
title_short | Geometric Calibration and Accuracy Verification of the GF-3 Satellite |
title_sort | geometric calibration and accuracy verification of the gf-3 satellite |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5621162/ https://www.ncbi.nlm.nih.gov/pubmed/28850055 http://dx.doi.org/10.3390/s17091977 |
work_keys_str_mv | AT zhaoruishan geometriccalibrationandaccuracyverificationofthegf3satellite AT zhangguo geometriccalibrationandaccuracyverificationofthegf3satellite AT dengmingjun geometriccalibrationandaccuracyverificationofthegf3satellite AT xukai geometriccalibrationandaccuracyverificationofthegf3satellite AT guofengcheng geometriccalibrationandaccuracyverificationofthegf3satellite |