Cargando…

Repetitive Immunosensor with a Fiber-Optic Device and Antibody-Coated Magnetic Beads for Semi-Continuous Monitoring of Escherichia coli O157:H7

A rapid and reproducible fiber-optic immunosensor for Escherichia coli O157:H7 (E. coli O157:H7) was described. The biosensor consisted of a flow cell, an optical fiber with a thin Ni layer, and a PC linked fluorometer. First, the samples with E. coli O157:H7 were incubated with magnetic beads coate...

Descripción completa

Detalles Bibliográficos
Autores principales: Taniguchi, Midori, Saito, Hirokazu, Mitsubayashi, Kohji
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5621163/
https://www.ncbi.nlm.nih.gov/pubmed/28925937
http://dx.doi.org/10.3390/s17092145
_version_ 1783267699981287424
author Taniguchi, Midori
Saito, Hirokazu
Mitsubayashi, Kohji
author_facet Taniguchi, Midori
Saito, Hirokazu
Mitsubayashi, Kohji
author_sort Taniguchi, Midori
collection PubMed
description A rapid and reproducible fiber-optic immunosensor for Escherichia coli O157:H7 (E. coli O157:H7) was described. The biosensor consisted of a flow cell, an optical fiber with a thin Ni layer, and a PC linked fluorometer. First, the samples with E. coli O157:H7 were incubated with magnetic beads coated with anti-E. coli O157:H7 antibodies and anti-E. coli O157:H7 antibodies labeled cyanine 5 (Cy5) to make sandwich complexes. Then the Cy5-(E. coli O157:H7)-beads were injected into a flow cell and pulled to the magnetized Ni layer on the optical fiber set in the flow cell. An excitation light (λ = 635 nm) was used to illuminate the optical fiber, and the Cy5 florescent molecules facing the optical fiber were exposed to an evanescent wave from the optical fiber. The 670 nm fluorescent light was measured using a photodiode. Finally, the magnetic intensity of the Ni layer was removed and the Cy5-E. coli O157:H7-beads were washed out for the next immunoassay. E. coli O157:H7, diluted with phosphate buffer (PB), was measured from 1 × 10(5) to 1 × 10(7) cells/mL. The total time required for an assay was less than 15 min (except for the pretreatment process) and repeating immunoassay on one optical fiber was made possible.
format Online
Article
Text
id pubmed-5621163
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-56211632017-10-03 Repetitive Immunosensor with a Fiber-Optic Device and Antibody-Coated Magnetic Beads for Semi-Continuous Monitoring of Escherichia coli O157:H7 Taniguchi, Midori Saito, Hirokazu Mitsubayashi, Kohji Sensors (Basel) Article A rapid and reproducible fiber-optic immunosensor for Escherichia coli O157:H7 (E. coli O157:H7) was described. The biosensor consisted of a flow cell, an optical fiber with a thin Ni layer, and a PC linked fluorometer. First, the samples with E. coli O157:H7 were incubated with magnetic beads coated with anti-E. coli O157:H7 antibodies and anti-E. coli O157:H7 antibodies labeled cyanine 5 (Cy5) to make sandwich complexes. Then the Cy5-(E. coli O157:H7)-beads were injected into a flow cell and pulled to the magnetized Ni layer on the optical fiber set in the flow cell. An excitation light (λ = 635 nm) was used to illuminate the optical fiber, and the Cy5 florescent molecules facing the optical fiber were exposed to an evanescent wave from the optical fiber. The 670 nm fluorescent light was measured using a photodiode. Finally, the magnetic intensity of the Ni layer was removed and the Cy5-E. coli O157:H7-beads were washed out for the next immunoassay. E. coli O157:H7, diluted with phosphate buffer (PB), was measured from 1 × 10(5) to 1 × 10(7) cells/mL. The total time required for an assay was less than 15 min (except for the pretreatment process) and repeating immunoassay on one optical fiber was made possible. MDPI 2017-09-19 /pmc/articles/PMC5621163/ /pubmed/28925937 http://dx.doi.org/10.3390/s17092145 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Taniguchi, Midori
Saito, Hirokazu
Mitsubayashi, Kohji
Repetitive Immunosensor with a Fiber-Optic Device and Antibody-Coated Magnetic Beads for Semi-Continuous Monitoring of Escherichia coli O157:H7
title Repetitive Immunosensor with a Fiber-Optic Device and Antibody-Coated Magnetic Beads for Semi-Continuous Monitoring of Escherichia coli O157:H7
title_full Repetitive Immunosensor with a Fiber-Optic Device and Antibody-Coated Magnetic Beads for Semi-Continuous Monitoring of Escherichia coli O157:H7
title_fullStr Repetitive Immunosensor with a Fiber-Optic Device and Antibody-Coated Magnetic Beads for Semi-Continuous Monitoring of Escherichia coli O157:H7
title_full_unstemmed Repetitive Immunosensor with a Fiber-Optic Device and Antibody-Coated Magnetic Beads for Semi-Continuous Monitoring of Escherichia coli O157:H7
title_short Repetitive Immunosensor with a Fiber-Optic Device and Antibody-Coated Magnetic Beads for Semi-Continuous Monitoring of Escherichia coli O157:H7
title_sort repetitive immunosensor with a fiber-optic device and antibody-coated magnetic beads for semi-continuous monitoring of escherichia coli o157:h7
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5621163/
https://www.ncbi.nlm.nih.gov/pubmed/28925937
http://dx.doi.org/10.3390/s17092145
work_keys_str_mv AT taniguchimidori repetitiveimmunosensorwithafiberopticdeviceandantibodycoatedmagneticbeadsforsemicontinuousmonitoringofescherichiacolio157h7
AT saitohirokazu repetitiveimmunosensorwithafiberopticdeviceandantibodycoatedmagneticbeadsforsemicontinuousmonitoringofescherichiacolio157h7
AT mitsubayashikohji repetitiveimmunosensorwithafiberopticdeviceandantibodycoatedmagneticbeadsforsemicontinuousmonitoringofescherichiacolio157h7