A Portable Impedance Immunosensing System for Rapid Detection of Salmonella Typhimurium

Salmonella Typhimurium is one of the most dangerous foodborne pathogens and poses a significant threat to human health. The objective of this study was to develop a portable impedance immunosensing system for rapid and sensitive detection of S. Typhimurium in poultry. The developed portable impedanc...

Descripción completa

Detalles Bibliográficos
Autores principales: Wen, Tao, Wang, Ronghui, Sotero, America, Li, Yanbin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5621372/
https://www.ncbi.nlm.nih.gov/pubmed/28846643
http://dx.doi.org/10.3390/s17091973
_version_ 1783267747705126912
author Wen, Tao
Wang, Ronghui
Sotero, America
Li, Yanbin
author_facet Wen, Tao
Wang, Ronghui
Sotero, America
Li, Yanbin
author_sort Wen, Tao
collection PubMed
description Salmonella Typhimurium is one of the most dangerous foodborne pathogens and poses a significant threat to human health. The objective of this study was to develop a portable impedance immunosensing system for rapid and sensitive detection of S. Typhimurium in poultry. The developed portable impedance immunosensing system consisted of a gold interdigitated array microelectrode (IDAM), a signal acquisitive interface and a laptop computer with LabVIEW software. The IDAM was first functionalized with 16-Mercaptohexadecanoic acid, and streptavidin was immobilized onto the electrode surface through covalent bonding. Then, biotin-labelled S. Typhimurium-antibody was immobilized onto the IDAM surface. Samples were dropped on the surface of the IDAM and the S. Typhimurium cells in the samples were captured by the antibody on the IDAM. This resulted in impedance changes that were measured and displayed with the LabVIEW software. An equivalent circuit of the immunosensor demonstrated that the largest change in impedance was due to the electron-transfer resistance. The equivalent circuit showed an increase of 35% for the electron-transfer resistance value compared to the negative control. The calibration result indicated that the portable impedance immunosensing system could be used to measure the standard impedance elements, and it had a maximum error of measurement of approximately 13%. For pure culture detection, the system had a linear relationship between the impedance change and the logarithmic value of S. Typhimurium cells ranging from 76 to 7.6 × 10(6) CFU (colony-forming unit) (50 μL)(−1). The immunosensor also had a correlation coefficient of 0.98, and a high specificity for detection of S. Typhimurium cells with a limit of detection (LOD) of 10(2) CFU (50 μL)(−1). The detection time from the moment a sample was introduced to the display of the results was 1 h. To conclude, the portable impedance immunosensing system for detection of S. Typhimurium achieved an LOD that is comparable with commercial electrochemical impedance instruments. The developed impedance immunosensor has advantages in portability, low cost, rapid detection and label-free features showing a great potential for in-field detection of foodborne pathogens.
format Online
Article
Text
id pubmed-5621372
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-56213722017-10-03 A Portable Impedance Immunosensing System for Rapid Detection of Salmonella Typhimurium Wen, Tao Wang, Ronghui Sotero, America Li, Yanbin Sensors (Basel) Article Salmonella Typhimurium is one of the most dangerous foodborne pathogens and poses a significant threat to human health. The objective of this study was to develop a portable impedance immunosensing system for rapid and sensitive detection of S. Typhimurium in poultry. The developed portable impedance immunosensing system consisted of a gold interdigitated array microelectrode (IDAM), a signal acquisitive interface and a laptop computer with LabVIEW software. The IDAM was first functionalized with 16-Mercaptohexadecanoic acid, and streptavidin was immobilized onto the electrode surface through covalent bonding. Then, biotin-labelled S. Typhimurium-antibody was immobilized onto the IDAM surface. Samples were dropped on the surface of the IDAM and the S. Typhimurium cells in the samples were captured by the antibody on the IDAM. This resulted in impedance changes that were measured and displayed with the LabVIEW software. An equivalent circuit of the immunosensor demonstrated that the largest change in impedance was due to the electron-transfer resistance. The equivalent circuit showed an increase of 35% for the electron-transfer resistance value compared to the negative control. The calibration result indicated that the portable impedance immunosensing system could be used to measure the standard impedance elements, and it had a maximum error of measurement of approximately 13%. For pure culture detection, the system had a linear relationship between the impedance change and the logarithmic value of S. Typhimurium cells ranging from 76 to 7.6 × 10(6) CFU (colony-forming unit) (50 μL)(−1). The immunosensor also had a correlation coefficient of 0.98, and a high specificity for detection of S. Typhimurium cells with a limit of detection (LOD) of 10(2) CFU (50 μL)(−1). The detection time from the moment a sample was introduced to the display of the results was 1 h. To conclude, the portable impedance immunosensing system for detection of S. Typhimurium achieved an LOD that is comparable with commercial electrochemical impedance instruments. The developed impedance immunosensor has advantages in portability, low cost, rapid detection and label-free features showing a great potential for in-field detection of foodborne pathogens. MDPI 2017-08-28 /pmc/articles/PMC5621372/ /pubmed/28846643 http://dx.doi.org/10.3390/s17091973 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Wen, Tao
Wang, Ronghui
Sotero, America
Li, Yanbin
A Portable Impedance Immunosensing System for Rapid Detection of Salmonella Typhimurium
title A Portable Impedance Immunosensing System for Rapid Detection of Salmonella Typhimurium
title_full A Portable Impedance Immunosensing System for Rapid Detection of Salmonella Typhimurium
title_fullStr A Portable Impedance Immunosensing System for Rapid Detection of Salmonella Typhimurium
title_full_unstemmed A Portable Impedance Immunosensing System for Rapid Detection of Salmonella Typhimurium
title_short A Portable Impedance Immunosensing System for Rapid Detection of Salmonella Typhimurium
title_sort portable impedance immunosensing system for rapid detection of salmonella typhimurium
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5621372/
https://www.ncbi.nlm.nih.gov/pubmed/28846643
http://dx.doi.org/10.3390/s17091973
work_keys_str_mv AT wentao aportableimpedanceimmunosensingsystemforrapiddetectionofsalmonellatyphimurium
AT wangronghui aportableimpedanceimmunosensingsystemforrapiddetectionofsalmonellatyphimurium
AT soteroamerica aportableimpedanceimmunosensingsystemforrapiddetectionofsalmonellatyphimurium
AT liyanbin aportableimpedanceimmunosensingsystemforrapiddetectionofsalmonellatyphimurium
AT wentao portableimpedanceimmunosensingsystemforrapiddetectionofsalmonellatyphimurium
AT wangronghui portableimpedanceimmunosensingsystemforrapiddetectionofsalmonellatyphimurium
AT soteroamerica portableimpedanceimmunosensingsystemforrapiddetectionofsalmonellatyphimurium
AT liyanbin portableimpedanceimmunosensingsystemforrapiddetectionofsalmonellatyphimurium