Cargando…

Response Characteristics and Experimental Study of Underground Magnetic Resonance Sounding Using a Small-Coil Sensor

Due to its unique sensitivity to hydrogen protons, magnetic resonance sounding (MRS) is the only geophysical method that directly detects water and can provide nondestructive information on subsurface aquifer properties. The relationship between the surface MRS signal and the location and characteri...

Descripción completa

Detalles Bibliográficos
Autores principales: Qin, Shengwu, Ma, Zhongjun, Jiang, Chuandong, Lin, Jun, Xue, Yiguo, Shang, Xinlei, Li, Zhiqiang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5621384/
https://www.ncbi.nlm.nih.gov/pubmed/28926929
http://dx.doi.org/10.3390/s17092127
_version_ 1783267749324128256
author Qin, Shengwu
Ma, Zhongjun
Jiang, Chuandong
Lin, Jun
Xue, Yiguo
Shang, Xinlei
Li, Zhiqiang
author_facet Qin, Shengwu
Ma, Zhongjun
Jiang, Chuandong
Lin, Jun
Xue, Yiguo
Shang, Xinlei
Li, Zhiqiang
author_sort Qin, Shengwu
collection PubMed
description Due to its unique sensitivity to hydrogen protons, magnetic resonance sounding (MRS) is the only geophysical method that directly detects water and can provide nondestructive information on subsurface aquifer properties. The relationship between the surface MRS signal and the location and characteristics of aquifers using large-coil (typically 50–150 m) sensors has been discussed based on forward modelling and experiments. However, few researchers have studied underground MRS using a small-coil sensor. In this paper, a parametric study and a large-scale physical model test were conducted to shed light on the critical response characteristics of underground MRS using a small-coil sensor. The effects of the size and number of turns of the transmitter coil and receiver coil, the geomagnetic declination, the geomagnetic inclination, and the position, thickness, and water content of a water-bearing structure on the performance of the underground MRS were studied based on numerical simulations. Furthermore, we derived the kernel function and underground MRS signal curves for a water-bearing structure model based on the simulations. Finally, a large-scale physical model test on underground MRS using a small-coil sensor was performed using a physical test system for geological prediction of tunnels at Shandong University. The results show that the inversion results of the physical model test were in good agreement with the physical prototype results. Using both numerical modeling and physical model tests, this study showed that underground MRS using a small-coil sensor can be used to predict water-bearing structures in underground engineering.
format Online
Article
Text
id pubmed-5621384
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-56213842017-10-03 Response Characteristics and Experimental Study of Underground Magnetic Resonance Sounding Using a Small-Coil Sensor Qin, Shengwu Ma, Zhongjun Jiang, Chuandong Lin, Jun Xue, Yiguo Shang, Xinlei Li, Zhiqiang Sensors (Basel) Article Due to its unique sensitivity to hydrogen protons, magnetic resonance sounding (MRS) is the only geophysical method that directly detects water and can provide nondestructive information on subsurface aquifer properties. The relationship between the surface MRS signal and the location and characteristics of aquifers using large-coil (typically 50–150 m) sensors has been discussed based on forward modelling and experiments. However, few researchers have studied underground MRS using a small-coil sensor. In this paper, a parametric study and a large-scale physical model test were conducted to shed light on the critical response characteristics of underground MRS using a small-coil sensor. The effects of the size and number of turns of the transmitter coil and receiver coil, the geomagnetic declination, the geomagnetic inclination, and the position, thickness, and water content of a water-bearing structure on the performance of the underground MRS were studied based on numerical simulations. Furthermore, we derived the kernel function and underground MRS signal curves for a water-bearing structure model based on the simulations. Finally, a large-scale physical model test on underground MRS using a small-coil sensor was performed using a physical test system for geological prediction of tunnels at Shandong University. The results show that the inversion results of the physical model test were in good agreement with the physical prototype results. Using both numerical modeling and physical model tests, this study showed that underground MRS using a small-coil sensor can be used to predict water-bearing structures in underground engineering. MDPI 2017-09-15 /pmc/articles/PMC5621384/ /pubmed/28926929 http://dx.doi.org/10.3390/s17092127 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Qin, Shengwu
Ma, Zhongjun
Jiang, Chuandong
Lin, Jun
Xue, Yiguo
Shang, Xinlei
Li, Zhiqiang
Response Characteristics and Experimental Study of Underground Magnetic Resonance Sounding Using a Small-Coil Sensor
title Response Characteristics and Experimental Study of Underground Magnetic Resonance Sounding Using a Small-Coil Sensor
title_full Response Characteristics and Experimental Study of Underground Magnetic Resonance Sounding Using a Small-Coil Sensor
title_fullStr Response Characteristics and Experimental Study of Underground Magnetic Resonance Sounding Using a Small-Coil Sensor
title_full_unstemmed Response Characteristics and Experimental Study of Underground Magnetic Resonance Sounding Using a Small-Coil Sensor
title_short Response Characteristics and Experimental Study of Underground Magnetic Resonance Sounding Using a Small-Coil Sensor
title_sort response characteristics and experimental study of underground magnetic resonance sounding using a small-coil sensor
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5621384/
https://www.ncbi.nlm.nih.gov/pubmed/28926929
http://dx.doi.org/10.3390/s17092127
work_keys_str_mv AT qinshengwu responsecharacteristicsandexperimentalstudyofundergroundmagneticresonancesoundingusingasmallcoilsensor
AT mazhongjun responsecharacteristicsandexperimentalstudyofundergroundmagneticresonancesoundingusingasmallcoilsensor
AT jiangchuandong responsecharacteristicsandexperimentalstudyofundergroundmagneticresonancesoundingusingasmallcoilsensor
AT linjun responsecharacteristicsandexperimentalstudyofundergroundmagneticresonancesoundingusingasmallcoilsensor
AT xueyiguo responsecharacteristicsandexperimentalstudyofundergroundmagneticresonancesoundingusingasmallcoilsensor
AT shangxinlei responsecharacteristicsandexperimentalstudyofundergroundmagneticresonancesoundingusingasmallcoilsensor
AT lizhiqiang responsecharacteristicsandexperimentalstudyofundergroundmagneticresonancesoundingusingasmallcoilsensor