The accuracy of postoperative, non-invasive Air-Test to diagnose atelectasis in healthy patients after surgery: a prospective, diagnostic pilot study
OBJECTIVE: To assess the diagnostic accuracy of peripheral capillary oxygen saturation (SpO(2)) while breathing room air for 5 min (the ‘Air-Test’) in detecting postoperative atelectasis. DESIGN: Prospective cohort study. Diagnostic accuracy was assessed by measuring the agreement between the index...
Autores principales: | , , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Open
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5623366/ https://www.ncbi.nlm.nih.gov/pubmed/28554935 http://dx.doi.org/10.1136/bmjopen-2016-015560 |
Sumario: | OBJECTIVE: To assess the diagnostic accuracy of peripheral capillary oxygen saturation (SpO(2)) while breathing room air for 5 min (the ‘Air-Test’) in detecting postoperative atelectasis. DESIGN: Prospective cohort study. Diagnostic accuracy was assessed by measuring the agreement between the index test and the reference standard CT scan images. SETTING: Postanaesthetic care unit in a tertiary hospital in Spain. PARTICIPANTS: Three hundred and fifty patients from 12 January to 7 February 2015; 170 patients scheduled for surgery under general anaesthesia who were admitted into the postsurgical unit were included. INTERVENTION: The Air-Test was performed in conscious extubated patients after a 30 min stabilisation period during which they received supplemental oxygen therapy via a venturi mask. The Air-Test was defined as positive when SpO(2) was ≤96% and negative when SpO(2) was ≥97%. Arterial blood gases were measured in all patients at the end of the Air-Test. In the subsequent 25 min, the presence of atelectasis was evaluated by performing a CT scan in 59 randomly selected patients. MAIN OUTCOME MEASURES: The primary study outcome was assessment of the accuracy of the Air-Test for detecting postoperative atelectasis compared with the reference standard. The secondary outcome was the incidence of positive Air-Test results. RESULTS: The Air-Test diagnosed postoperative atelectasis with an area under the receiver operating characteristic curve of 0.90 (95% CI 0.82 to 0.98) with a sensitivity of 82.6% and a specificity of 87.8%. The presence of atelectasis was confirmed by CT scans in all patients (30/30) with positive and in 5 patients (17%) with negative Air-Test results. Based on the Air-Test, postoperative atelectasis was present in 36% of the patients (62 out of 170). CONCLUSION: The Air-Test may represent an accurate, simple, inexpensive and non-invasive method for diagnosing postoperative atelectasis. TRIAL REGISTRATION: NCT02650037. |
---|