Cargando…

Improving the Robustness of Electromyogram-Pattern Recognition for Prosthetic Control by a Postprocessing Strategy

Electromyogram (EMG) contains rich information for motion decoding. As one of its major applications, EMG-pattern recognition (PR)-based control of prostheses has been proposed and investigated in the field of rehabilitation robotics for decades. These prostheses can offer a higher level of dexterit...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Xu, Li, Xiangxin, Samuel, Oluwarotimi Williams, Huang, Zhen, Fang, Peng, Li, Guanglin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5623687/
https://www.ncbi.nlm.nih.gov/pubmed/29021753
http://dx.doi.org/10.3389/fnbot.2017.00051
_version_ 1783268129238941696
author Zhang, Xu
Li, Xiangxin
Samuel, Oluwarotimi Williams
Huang, Zhen
Fang, Peng
Li, Guanglin
author_facet Zhang, Xu
Li, Xiangxin
Samuel, Oluwarotimi Williams
Huang, Zhen
Fang, Peng
Li, Guanglin
author_sort Zhang, Xu
collection PubMed
description Electromyogram (EMG) contains rich information for motion decoding. As one of its major applications, EMG-pattern recognition (PR)-based control of prostheses has been proposed and investigated in the field of rehabilitation robotics for decades. These prostheses can offer a higher level of dexterity compared to the commercially available ones. However, limited progress has been made toward clinical application of EMG-PR-based prostheses, due to their unsatisfactory robustness against various interferences during daily use. These interferences may lead to misclassifications of motion intentions, which damage the control performance of EMG-PR-based prostheses. A number of studies have applied methods that undergo a postprocessing stage to determine the current motion outputs, based on previous outputs or other information, which have proved effective in reducing erroneous outputs. In this study, we proposed a postprocessing strategy that locks the outputs during the constant contraction to block out occasional misclassifications, upon detecting the motion onset using a threshold. The strategy was investigated using three different motion onset detectors, namely mean absolute value, Teager–Kaiser energy operator, or mechanomyogram (MMG). Our results indicate that the proposed strategy could suppress erroneous outputs, during rest and constant contractions in particular. In addition, with MMG as the motion onset detector, the strategy was found to produce the most significant improvement in the performance, reducing the total errors up to around 50% (from 22.9 to 11.5%) in comparison to the original classification output in the online test, and it is the most robust against threshold value changes. We speculate that motion onset detectors that are both smooth and responsive would further enhance the efficacy of the proposed postprocessing strategy, which would facilitate the clinical application of EMG-PR-based prosthetic control.
format Online
Article
Text
id pubmed-5623687
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-56236872017-10-11 Improving the Robustness of Electromyogram-Pattern Recognition for Prosthetic Control by a Postprocessing Strategy Zhang, Xu Li, Xiangxin Samuel, Oluwarotimi Williams Huang, Zhen Fang, Peng Li, Guanglin Front Neurorobot Neuroscience Electromyogram (EMG) contains rich information for motion decoding. As one of its major applications, EMG-pattern recognition (PR)-based control of prostheses has been proposed and investigated in the field of rehabilitation robotics for decades. These prostheses can offer a higher level of dexterity compared to the commercially available ones. However, limited progress has been made toward clinical application of EMG-PR-based prostheses, due to their unsatisfactory robustness against various interferences during daily use. These interferences may lead to misclassifications of motion intentions, which damage the control performance of EMG-PR-based prostheses. A number of studies have applied methods that undergo a postprocessing stage to determine the current motion outputs, based on previous outputs or other information, which have proved effective in reducing erroneous outputs. In this study, we proposed a postprocessing strategy that locks the outputs during the constant contraction to block out occasional misclassifications, upon detecting the motion onset using a threshold. The strategy was investigated using three different motion onset detectors, namely mean absolute value, Teager–Kaiser energy operator, or mechanomyogram (MMG). Our results indicate that the proposed strategy could suppress erroneous outputs, during rest and constant contractions in particular. In addition, with MMG as the motion onset detector, the strategy was found to produce the most significant improvement in the performance, reducing the total errors up to around 50% (from 22.9 to 11.5%) in comparison to the original classification output in the online test, and it is the most robust against threshold value changes. We speculate that motion onset detectors that are both smooth and responsive would further enhance the efficacy of the proposed postprocessing strategy, which would facilitate the clinical application of EMG-PR-based prosthetic control. Frontiers Media S.A. 2017-09-27 /pmc/articles/PMC5623687/ /pubmed/29021753 http://dx.doi.org/10.3389/fnbot.2017.00051 Text en Copyright © 2017 Zhang, Li, Samuel, Huang, Fang and Li. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neuroscience
Zhang, Xu
Li, Xiangxin
Samuel, Oluwarotimi Williams
Huang, Zhen
Fang, Peng
Li, Guanglin
Improving the Robustness of Electromyogram-Pattern Recognition for Prosthetic Control by a Postprocessing Strategy
title Improving the Robustness of Electromyogram-Pattern Recognition for Prosthetic Control by a Postprocessing Strategy
title_full Improving the Robustness of Electromyogram-Pattern Recognition for Prosthetic Control by a Postprocessing Strategy
title_fullStr Improving the Robustness of Electromyogram-Pattern Recognition for Prosthetic Control by a Postprocessing Strategy
title_full_unstemmed Improving the Robustness of Electromyogram-Pattern Recognition for Prosthetic Control by a Postprocessing Strategy
title_short Improving the Robustness of Electromyogram-Pattern Recognition for Prosthetic Control by a Postprocessing Strategy
title_sort improving the robustness of electromyogram-pattern recognition for prosthetic control by a postprocessing strategy
topic Neuroscience
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5623687/
https://www.ncbi.nlm.nih.gov/pubmed/29021753
http://dx.doi.org/10.3389/fnbot.2017.00051
work_keys_str_mv AT zhangxu improvingtherobustnessofelectromyogrampatternrecognitionforprostheticcontrolbyapostprocessingstrategy
AT lixiangxin improvingtherobustnessofelectromyogrampatternrecognitionforprostheticcontrolbyapostprocessingstrategy
AT samueloluwarotimiwilliams improvingtherobustnessofelectromyogrampatternrecognitionforprostheticcontrolbyapostprocessingstrategy
AT huangzhen improvingtherobustnessofelectromyogrampatternrecognitionforprostheticcontrolbyapostprocessingstrategy
AT fangpeng improvingtherobustnessofelectromyogrampatternrecognitionforprostheticcontrolbyapostprocessingstrategy
AT liguanglin improvingtherobustnessofelectromyogrampatternrecognitionforprostheticcontrolbyapostprocessingstrategy