Cargando…

The comparison of measurement between ultrasound and computed tomography for abnormal degenerative facet joints: A STROBE-compliant article

Besides the study on examining facet joints of lumbar spine by ultrasound in normal population, there has not been any related report about examining normal facet joints of lumbar spine by ultrasound so far. This study was aimed to explore the feasibility of ultrasound assessment of lumber spine fac...

Descripción completa

Detalles Bibliográficos
Autores principales: Shi, Wen, Tian, Dan, Liu, Da, Yin, Jing, Huang, Ying
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5626149/
https://www.ncbi.nlm.nih.gov/pubmed/28767595
http://dx.doi.org/10.1097/MD.0000000000007680
_version_ 1783268501143683072
author Shi, Wen
Tian, Dan
Liu, Da
Yin, Jing
Huang, Ying
author_facet Shi, Wen
Tian, Dan
Liu, Da
Yin, Jing
Huang, Ying
author_sort Shi, Wen
collection PubMed
description Besides the study on examining facet joints of lumbar spine by ultrasound in normal population, there has not been any related report about examining normal facet joints of lumbar spine by ultrasound so far. This study was aimed to explore the feasibility of ultrasound assessment of lumber spine facet joints by comparing ultrasound measure values of normal and degenerative lumber spine facet joints, and by comparing measure values of ultrasound and computed tomography (CT) of degenerative lumber spine facet joints. This study included 15 patients who had chronic low back pain because of degenerative change in lumbar vertebrae, and 19 volunteers who did not have low back pain or pain in the lower limb. The ultrasound measure values (height [H] and width [W]) of normal and degenerative lumber spine facet joints were compared. And the differentiation between measure values (H and W) of ultrasound and CT of degenerative lumber spine facet joints was also analyzed. The ultrasound clearly showed abnormal facet joints lesion, which was characterized by hyperostosis on the edge of joints, bone destruction under joints, and thinner or thicker articular cartilage. There were significant differences between the ultrasound measure values of the normal (H: 1.26 ± 0.03 cm, W: 0.18 ± 0.01 cm) and abnormal facet joints (H: 1.43 ± 0.05 cm, W: 0.15 ± 0.02 cm) (all P < .05). However, there were no significant differences between the measure values of the ultrasound (H: 1.43 ± 0.17 cm, W: 0.15 ± 0.03 cm) and CT (H: 1.42 ± 0.16, W: 0.14 ± 0.03) of the degenerative lumber spine facet joints (all P > .05). Ultrasound can clearly show the structure of facet joints of lumbar spine. It is precise and feasible to assess facet joints of lumbar spine by ultrasound. This study has important significance for the diagnosis of lumbar facet joint degeneration.
format Online
Article
Text
id pubmed-5626149
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-56261492017-10-11 The comparison of measurement between ultrasound and computed tomography for abnormal degenerative facet joints: A STROBE-compliant article Shi, Wen Tian, Dan Liu, Da Yin, Jing Huang, Ying Medicine (Baltimore) 4100 Besides the study on examining facet joints of lumbar spine by ultrasound in normal population, there has not been any related report about examining normal facet joints of lumbar spine by ultrasound so far. This study was aimed to explore the feasibility of ultrasound assessment of lumber spine facet joints by comparing ultrasound measure values of normal and degenerative lumber spine facet joints, and by comparing measure values of ultrasound and computed tomography (CT) of degenerative lumber spine facet joints. This study included 15 patients who had chronic low back pain because of degenerative change in lumbar vertebrae, and 19 volunteers who did not have low back pain or pain in the lower limb. The ultrasound measure values (height [H] and width [W]) of normal and degenerative lumber spine facet joints were compared. And the differentiation between measure values (H and W) of ultrasound and CT of degenerative lumber spine facet joints was also analyzed. The ultrasound clearly showed abnormal facet joints lesion, which was characterized by hyperostosis on the edge of joints, bone destruction under joints, and thinner or thicker articular cartilage. There were significant differences between the ultrasound measure values of the normal (H: 1.26 ± 0.03 cm, W: 0.18 ± 0.01 cm) and abnormal facet joints (H: 1.43 ± 0.05 cm, W: 0.15 ± 0.02 cm) (all P < .05). However, there were no significant differences between the measure values of the ultrasound (H: 1.43 ± 0.17 cm, W: 0.15 ± 0.03 cm) and CT (H: 1.42 ± 0.16, W: 0.14 ± 0.03) of the degenerative lumber spine facet joints (all P > .05). Ultrasound can clearly show the structure of facet joints of lumbar spine. It is precise and feasible to assess facet joints of lumbar spine by ultrasound. This study has important significance for the diagnosis of lumbar facet joint degeneration. Wolters Kluwer Health 2017-08-04 /pmc/articles/PMC5626149/ /pubmed/28767595 http://dx.doi.org/10.1097/MD.0000000000007680 Text en Copyright © 2017 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by-nd/4.0 This is an open access article distributed under the Creative Commons Attribution-No Derivatives License 4.0, which allows for redistribution, commercial and noncommercial, as long as it is passed along unchanged and in whole, with credit to the author. http://creativecommons.org/licenses/by-nd/4.0
spellingShingle 4100
Shi, Wen
Tian, Dan
Liu, Da
Yin, Jing
Huang, Ying
The comparison of measurement between ultrasound and computed tomography for abnormal degenerative facet joints: A STROBE-compliant article
title The comparison of measurement between ultrasound and computed tomography for abnormal degenerative facet joints: A STROBE-compliant article
title_full The comparison of measurement between ultrasound and computed tomography for abnormal degenerative facet joints: A STROBE-compliant article
title_fullStr The comparison of measurement between ultrasound and computed tomography for abnormal degenerative facet joints: A STROBE-compliant article
title_full_unstemmed The comparison of measurement between ultrasound and computed tomography for abnormal degenerative facet joints: A STROBE-compliant article
title_short The comparison of measurement between ultrasound and computed tomography for abnormal degenerative facet joints: A STROBE-compliant article
title_sort comparison of measurement between ultrasound and computed tomography for abnormal degenerative facet joints: a strobe-compliant article
topic 4100
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5626149/
https://www.ncbi.nlm.nih.gov/pubmed/28767595
http://dx.doi.org/10.1097/MD.0000000000007680
work_keys_str_mv AT shiwen thecomparisonofmeasurementbetweenultrasoundandcomputedtomographyforabnormaldegenerativefacetjointsastrobecompliantarticle
AT tiandan thecomparisonofmeasurementbetweenultrasoundandcomputedtomographyforabnormaldegenerativefacetjointsastrobecompliantarticle
AT liuda thecomparisonofmeasurementbetweenultrasoundandcomputedtomographyforabnormaldegenerativefacetjointsastrobecompliantarticle
AT yinjing thecomparisonofmeasurementbetweenultrasoundandcomputedtomographyforabnormaldegenerativefacetjointsastrobecompliantarticle
AT huangying thecomparisonofmeasurementbetweenultrasoundandcomputedtomographyforabnormaldegenerativefacetjointsastrobecompliantarticle
AT shiwen comparisonofmeasurementbetweenultrasoundandcomputedtomographyforabnormaldegenerativefacetjointsastrobecompliantarticle
AT tiandan comparisonofmeasurementbetweenultrasoundandcomputedtomographyforabnormaldegenerativefacetjointsastrobecompliantarticle
AT liuda comparisonofmeasurementbetweenultrasoundandcomputedtomographyforabnormaldegenerativefacetjointsastrobecompliantarticle
AT yinjing comparisonofmeasurementbetweenultrasoundandcomputedtomographyforabnormaldegenerativefacetjointsastrobecompliantarticle
AT huangying comparisonofmeasurementbetweenultrasoundandcomputedtomographyforabnormaldegenerativefacetjointsastrobecompliantarticle