Cargando…

Intraoperative optical coherence tomography and ab interno trabecular meshwork surgery with the Trabectome

IMPORTANCE: This study is the first description of the use of the intraoperative optical coherence tomography (iOCT) for trabecular meshwork surgery with the Trabectome in a regular clinical setting. BACKGROUND: The aim of this study is to evaluate intraoperatively the immediate success of ab intern...

Descripción completa

Detalles Bibliográficos
Autores principales: Junker, Bernd, Jordan, Jens F, Framme, Carsten, Pielen, Amelie
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5627725/
https://www.ncbi.nlm.nih.gov/pubmed/29026286
http://dx.doi.org/10.2147/OPTH.S145873
_version_ 1783268756874592256
author Junker, Bernd
Jordan, Jens F
Framme, Carsten
Pielen, Amelie
author_facet Junker, Bernd
Jordan, Jens F
Framme, Carsten
Pielen, Amelie
author_sort Junker, Bernd
collection PubMed
description IMPORTANCE: This study is the first description of the use of the intraoperative optical coherence tomography (iOCT) for trabecular meshwork surgery with the Trabectome in a regular clinical setting. BACKGROUND: The aim of this study is to evaluate intraoperatively the immediate success of ab interno trabeculotomy with the Trabectome defined as a removal of the trabecular meshwork. DESIGN: This is a retrospective clinical study performed in the University Eye Hospital, Medical School Hannover. PARTICIPANTS: A total of nine consecutive Caucasian patients suffering from primary open angle glaucoma, pigment dispersion glaucoma, or pseudoexfoliation glaucoma took part in the study. METHODS: All patients underwent ab interno trabeculotomy surgery with the Trabectome using a commercially available iOCT to visualize the anterior chamber angle (ACA) before and after the procedure. The visualization was done using a modified Swan-Jacobs lens (all nine patients) or without lens (view from above, five patients). MAIN OUTCOME MEASURES: The main outcome of this study is the success of visualization of the ACA on iOCT, especially the postprocedural visualization of the wound gap after removal of the trabecular meshwork. RESULTS: Using the view from above, the ACA could be visualized before and after the procedure in only two of the five cases. Using the modified Swan-Jacobs lens, the ACA could be visualized before the procedure and the trabecular meshwork opening after the procedure in all nine patients. CONCLUSION: The iOCT can be used to objectify the immediate success of the surgical procedure, ie, the removal of the trabecular meshwork, of ab interno trabeculotomy with the Trabectome. The procedure itself cannot be captured sufficiently via iOCT.
format Online
Article
Text
id pubmed-5627725
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-56277252017-10-12 Intraoperative optical coherence tomography and ab interno trabecular meshwork surgery with the Trabectome Junker, Bernd Jordan, Jens F Framme, Carsten Pielen, Amelie Clin Ophthalmol Original Research IMPORTANCE: This study is the first description of the use of the intraoperative optical coherence tomography (iOCT) for trabecular meshwork surgery with the Trabectome in a regular clinical setting. BACKGROUND: The aim of this study is to evaluate intraoperatively the immediate success of ab interno trabeculotomy with the Trabectome defined as a removal of the trabecular meshwork. DESIGN: This is a retrospective clinical study performed in the University Eye Hospital, Medical School Hannover. PARTICIPANTS: A total of nine consecutive Caucasian patients suffering from primary open angle glaucoma, pigment dispersion glaucoma, or pseudoexfoliation glaucoma took part in the study. METHODS: All patients underwent ab interno trabeculotomy surgery with the Trabectome using a commercially available iOCT to visualize the anterior chamber angle (ACA) before and after the procedure. The visualization was done using a modified Swan-Jacobs lens (all nine patients) or without lens (view from above, five patients). MAIN OUTCOME MEASURES: The main outcome of this study is the success of visualization of the ACA on iOCT, especially the postprocedural visualization of the wound gap after removal of the trabecular meshwork. RESULTS: Using the view from above, the ACA could be visualized before and after the procedure in only two of the five cases. Using the modified Swan-Jacobs lens, the ACA could be visualized before the procedure and the trabecular meshwork opening after the procedure in all nine patients. CONCLUSION: The iOCT can be used to objectify the immediate success of the surgical procedure, ie, the removal of the trabecular meshwork, of ab interno trabeculotomy with the Trabectome. The procedure itself cannot be captured sufficiently via iOCT. Dove Medical Press 2017-09-28 /pmc/articles/PMC5627725/ /pubmed/29026286 http://dx.doi.org/10.2147/OPTH.S145873 Text en © 2017 Junker et al. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.
spellingShingle Original Research
Junker, Bernd
Jordan, Jens F
Framme, Carsten
Pielen, Amelie
Intraoperative optical coherence tomography and ab interno trabecular meshwork surgery with the Trabectome
title Intraoperative optical coherence tomography and ab interno trabecular meshwork surgery with the Trabectome
title_full Intraoperative optical coherence tomography and ab interno trabecular meshwork surgery with the Trabectome
title_fullStr Intraoperative optical coherence tomography and ab interno trabecular meshwork surgery with the Trabectome
title_full_unstemmed Intraoperative optical coherence tomography and ab interno trabecular meshwork surgery with the Trabectome
title_short Intraoperative optical coherence tomography and ab interno trabecular meshwork surgery with the Trabectome
title_sort intraoperative optical coherence tomography and ab interno trabecular meshwork surgery with the trabectome
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5627725/
https://www.ncbi.nlm.nih.gov/pubmed/29026286
http://dx.doi.org/10.2147/OPTH.S145873
work_keys_str_mv AT junkerbernd intraoperativeopticalcoherencetomographyandabinternotrabecularmeshworksurgerywiththetrabectome
AT jordanjensf intraoperativeopticalcoherencetomographyandabinternotrabecularmeshworksurgerywiththetrabectome
AT frammecarsten intraoperativeopticalcoherencetomographyandabinternotrabecularmeshworksurgerywiththetrabectome
AT pielenamelie intraoperativeopticalcoherencetomographyandabinternotrabecularmeshworksurgerywiththetrabectome