Radiation reduction during percutaneous coronary intervention: A new protocol with a low frame rate and selective fluoroscopic image storage
The percutaneous coronary intervention (PCI) procedure is associated with potentially high levels of radiation exposure and therefore increased risk of adverse radiation-induced outcomes, ranging from cataract to malignancy. Frame rate reduction and selective fluoroscopy storage may help reduce radi...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer Health
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5627824/ https://www.ncbi.nlm.nih.gov/pubmed/28746198 http://dx.doi.org/10.1097/MD.0000000000007517 |
_version_ | 1783268775200555008 |
---|---|
author | Chon, Min Ku Chun, Kook Jin Lee, Dae Sung Lee, Soo Yong Hwang, Jongmin Lee, Sang Hyun Hwang, Ki Won Kim, Jeong Su Park, Young Huyn Kim, June Hong |
author_facet | Chon, Min Ku Chun, Kook Jin Lee, Dae Sung Lee, Soo Yong Hwang, Jongmin Lee, Sang Hyun Hwang, Ki Won Kim, Jeong Su Park, Young Huyn Kim, June Hong |
author_sort | Chon, Min Ku |
collection | PubMed |
description | The percutaneous coronary intervention (PCI) procedure is associated with potentially high levels of radiation exposure and therefore increased risk of adverse radiation-induced outcomes, ranging from cataract to malignancy. Frame rate reduction and selective fluoroscopy storage may help reduce radiation exposure. In this study, we evaluated the efficacy of a radiation reduction protocol that uses a lower frame rate and selective storage of fluoroscopic images in terms of its effect on reducing the radiation dose during PCI. The new protocol incorporated a lower frame rate as compared with the conventional protocol, and used selective storage of fluoroscopic images. We reviewed the medical records of patients who underwent PCI under the conventional protocol from January 2013 to December 2013, and compared them with those who underwent PCI with the new protocol from January 2015 to December 2015. The primary endpoint was radiation dose reduction expressed as cumulative air kerma and dose-area product (DAP). The image quality was assessed by 3 independent well-trained cardiologists. One hundred fifty-five patients were enrolled in the conventional protocol group, and 152 were enrolled in the radiation reduction protocol group (total, n = 307). There was no statistical significance in terms of the baseline characteristics, including body mass index. Overall, the radiation reduction protocol group showed a significant reduction in both cumulative air kerma (1634.39 ± 717.95 vs 2074.75 ± 1003.72 mGy, P < .001) and DAP (12344.86 ± 5371.75 vs 15312.19 ± 7136.58 μGy m(2), P < .001). Image quality was acceptable in both groups. The radiation reduction protocol, which uses a lower frame rate and selective storage of fluoroscopic images, may be an alternative approach to reducing PCI radiation dose. |
format | Online Article Text |
id | pubmed-5627824 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Wolters Kluwer Health |
record_format | MEDLINE/PubMed |
spelling | pubmed-56278242017-10-12 Radiation reduction during percutaneous coronary intervention: A new protocol with a low frame rate and selective fluoroscopic image storage Chon, Min Ku Chun, Kook Jin Lee, Dae Sung Lee, Soo Yong Hwang, Jongmin Lee, Sang Hyun Hwang, Ki Won Kim, Jeong Su Park, Young Huyn Kim, June Hong Medicine (Baltimore) 3400 The percutaneous coronary intervention (PCI) procedure is associated with potentially high levels of radiation exposure and therefore increased risk of adverse radiation-induced outcomes, ranging from cataract to malignancy. Frame rate reduction and selective fluoroscopy storage may help reduce radiation exposure. In this study, we evaluated the efficacy of a radiation reduction protocol that uses a lower frame rate and selective storage of fluoroscopic images in terms of its effect on reducing the radiation dose during PCI. The new protocol incorporated a lower frame rate as compared with the conventional protocol, and used selective storage of fluoroscopic images. We reviewed the medical records of patients who underwent PCI under the conventional protocol from January 2013 to December 2013, and compared them with those who underwent PCI with the new protocol from January 2015 to December 2015. The primary endpoint was radiation dose reduction expressed as cumulative air kerma and dose-area product (DAP). The image quality was assessed by 3 independent well-trained cardiologists. One hundred fifty-five patients were enrolled in the conventional protocol group, and 152 were enrolled in the radiation reduction protocol group (total, n = 307). There was no statistical significance in terms of the baseline characteristics, including body mass index. Overall, the radiation reduction protocol group showed a significant reduction in both cumulative air kerma (1634.39 ± 717.95 vs 2074.75 ± 1003.72 mGy, P < .001) and DAP (12344.86 ± 5371.75 vs 15312.19 ± 7136.58 μGy m(2), P < .001). Image quality was acceptable in both groups. The radiation reduction protocol, which uses a lower frame rate and selective storage of fluoroscopic images, may be an alternative approach to reducing PCI radiation dose. Wolters Kluwer Health 2017-07-28 /pmc/articles/PMC5627824/ /pubmed/28746198 http://dx.doi.org/10.1097/MD.0000000000007517 Text en Copyright © 2017 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by-nc-nd/4.0 This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0 |
spellingShingle | 3400 Chon, Min Ku Chun, Kook Jin Lee, Dae Sung Lee, Soo Yong Hwang, Jongmin Lee, Sang Hyun Hwang, Ki Won Kim, Jeong Su Park, Young Huyn Kim, June Hong Radiation reduction during percutaneous coronary intervention: A new protocol with a low frame rate and selective fluoroscopic image storage |
title | Radiation reduction during percutaneous coronary intervention: A new protocol with a low frame rate and selective fluoroscopic image storage |
title_full | Radiation reduction during percutaneous coronary intervention: A new protocol with a low frame rate and selective fluoroscopic image storage |
title_fullStr | Radiation reduction during percutaneous coronary intervention: A new protocol with a low frame rate and selective fluoroscopic image storage |
title_full_unstemmed | Radiation reduction during percutaneous coronary intervention: A new protocol with a low frame rate and selective fluoroscopic image storage |
title_short | Radiation reduction during percutaneous coronary intervention: A new protocol with a low frame rate and selective fluoroscopic image storage |
title_sort | radiation reduction during percutaneous coronary intervention: a new protocol with a low frame rate and selective fluoroscopic image storage |
topic | 3400 |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5627824/ https://www.ncbi.nlm.nih.gov/pubmed/28746198 http://dx.doi.org/10.1097/MD.0000000000007517 |
work_keys_str_mv | AT chonminku radiationreductionduringpercutaneouscoronaryinterventionanewprotocolwithalowframerateandselectivefluoroscopicimagestorage AT chunkookjin radiationreductionduringpercutaneouscoronaryinterventionanewprotocolwithalowframerateandselectivefluoroscopicimagestorage AT leedaesung radiationreductionduringpercutaneouscoronaryinterventionanewprotocolwithalowframerateandselectivefluoroscopicimagestorage AT leesooyong radiationreductionduringpercutaneouscoronaryinterventionanewprotocolwithalowframerateandselectivefluoroscopicimagestorage AT hwangjongmin radiationreductionduringpercutaneouscoronaryinterventionanewprotocolwithalowframerateandselectivefluoroscopicimagestorage AT leesanghyun radiationreductionduringpercutaneouscoronaryinterventionanewprotocolwithalowframerateandselectivefluoroscopicimagestorage AT hwangkiwon radiationreductionduringpercutaneouscoronaryinterventionanewprotocolwithalowframerateandselectivefluoroscopicimagestorage AT kimjeongsu radiationreductionduringpercutaneouscoronaryinterventionanewprotocolwithalowframerateandselectivefluoroscopicimagestorage AT parkyounghuyn radiationreductionduringpercutaneouscoronaryinterventionanewprotocolwithalowframerateandselectivefluoroscopicimagestorage AT kimjunehong radiationreductionduringpercutaneouscoronaryinterventionanewprotocolwithalowframerateandselectivefluoroscopicimagestorage |