Cargando…

Radiation reduction during percutaneous coronary intervention: A new protocol with a low frame rate and selective fluoroscopic image storage

The percutaneous coronary intervention (PCI) procedure is associated with potentially high levels of radiation exposure and therefore increased risk of adverse radiation-induced outcomes, ranging from cataract to malignancy. Frame rate reduction and selective fluoroscopy storage may help reduce radi...

Descripción completa

Detalles Bibliográficos
Autores principales: Chon, Min Ku, Chun, Kook Jin, Lee, Dae Sung, Lee, Soo Yong, Hwang, Jongmin, Lee, Sang Hyun, Hwang, Ki Won, Kim, Jeong Su, Park, Young Huyn, Kim, June Hong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5627824/
https://www.ncbi.nlm.nih.gov/pubmed/28746198
http://dx.doi.org/10.1097/MD.0000000000007517
_version_ 1783268775200555008
author Chon, Min Ku
Chun, Kook Jin
Lee, Dae Sung
Lee, Soo Yong
Hwang, Jongmin
Lee, Sang Hyun
Hwang, Ki Won
Kim, Jeong Su
Park, Young Huyn
Kim, June Hong
author_facet Chon, Min Ku
Chun, Kook Jin
Lee, Dae Sung
Lee, Soo Yong
Hwang, Jongmin
Lee, Sang Hyun
Hwang, Ki Won
Kim, Jeong Su
Park, Young Huyn
Kim, June Hong
author_sort Chon, Min Ku
collection PubMed
description The percutaneous coronary intervention (PCI) procedure is associated with potentially high levels of radiation exposure and therefore increased risk of adverse radiation-induced outcomes, ranging from cataract to malignancy. Frame rate reduction and selective fluoroscopy storage may help reduce radiation exposure. In this study, we evaluated the efficacy of a radiation reduction protocol that uses a lower frame rate and selective storage of fluoroscopic images in terms of its effect on reducing the radiation dose during PCI. The new protocol incorporated a lower frame rate as compared with the conventional protocol, and used selective storage of fluoroscopic images. We reviewed the medical records of patients who underwent PCI under the conventional protocol from January 2013 to December 2013, and compared them with those who underwent PCI with the new protocol from January 2015 to December 2015. The primary endpoint was radiation dose reduction expressed as cumulative air kerma and dose-area product (DAP). The image quality was assessed by 3 independent well-trained cardiologists. One hundred fifty-five patients were enrolled in the conventional protocol group, and 152 were enrolled in the radiation reduction protocol group (total, n = 307). There was no statistical significance in terms of the baseline characteristics, including body mass index. Overall, the radiation reduction protocol group showed a significant reduction in both cumulative air kerma (1634.39 ± 717.95 vs 2074.75 ± 1003.72 mGy, P < .001) and DAP (12344.86 ± 5371.75 vs 15312.19 ± 7136.58 μGy m(2), P < .001). Image quality was acceptable in both groups. The radiation reduction protocol, which uses a lower frame rate and selective storage of fluoroscopic images, may be an alternative approach to reducing PCI radiation dose.
format Online
Article
Text
id pubmed-5627824
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-56278242017-10-12 Radiation reduction during percutaneous coronary intervention: A new protocol with a low frame rate and selective fluoroscopic image storage Chon, Min Ku Chun, Kook Jin Lee, Dae Sung Lee, Soo Yong Hwang, Jongmin Lee, Sang Hyun Hwang, Ki Won Kim, Jeong Su Park, Young Huyn Kim, June Hong Medicine (Baltimore) 3400 The percutaneous coronary intervention (PCI) procedure is associated with potentially high levels of radiation exposure and therefore increased risk of adverse radiation-induced outcomes, ranging from cataract to malignancy. Frame rate reduction and selective fluoroscopy storage may help reduce radiation exposure. In this study, we evaluated the efficacy of a radiation reduction protocol that uses a lower frame rate and selective storage of fluoroscopic images in terms of its effect on reducing the radiation dose during PCI. The new protocol incorporated a lower frame rate as compared with the conventional protocol, and used selective storage of fluoroscopic images. We reviewed the medical records of patients who underwent PCI under the conventional protocol from January 2013 to December 2013, and compared them with those who underwent PCI with the new protocol from January 2015 to December 2015. The primary endpoint was radiation dose reduction expressed as cumulative air kerma and dose-area product (DAP). The image quality was assessed by 3 independent well-trained cardiologists. One hundred fifty-five patients were enrolled in the conventional protocol group, and 152 were enrolled in the radiation reduction protocol group (total, n = 307). There was no statistical significance in terms of the baseline characteristics, including body mass index. Overall, the radiation reduction protocol group showed a significant reduction in both cumulative air kerma (1634.39 ± 717.95 vs 2074.75 ± 1003.72 mGy, P < .001) and DAP (12344.86 ± 5371.75 vs 15312.19 ± 7136.58 μGy m(2), P < .001). Image quality was acceptable in both groups. The radiation reduction protocol, which uses a lower frame rate and selective storage of fluoroscopic images, may be an alternative approach to reducing PCI radiation dose. Wolters Kluwer Health 2017-07-28 /pmc/articles/PMC5627824/ /pubmed/28746198 http://dx.doi.org/10.1097/MD.0000000000007517 Text en Copyright © 2017 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by-nc-nd/4.0 This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0
spellingShingle 3400
Chon, Min Ku
Chun, Kook Jin
Lee, Dae Sung
Lee, Soo Yong
Hwang, Jongmin
Lee, Sang Hyun
Hwang, Ki Won
Kim, Jeong Su
Park, Young Huyn
Kim, June Hong
Radiation reduction during percutaneous coronary intervention: A new protocol with a low frame rate and selective fluoroscopic image storage
title Radiation reduction during percutaneous coronary intervention: A new protocol with a low frame rate and selective fluoroscopic image storage
title_full Radiation reduction during percutaneous coronary intervention: A new protocol with a low frame rate and selective fluoroscopic image storage
title_fullStr Radiation reduction during percutaneous coronary intervention: A new protocol with a low frame rate and selective fluoroscopic image storage
title_full_unstemmed Radiation reduction during percutaneous coronary intervention: A new protocol with a low frame rate and selective fluoroscopic image storage
title_short Radiation reduction during percutaneous coronary intervention: A new protocol with a low frame rate and selective fluoroscopic image storage
title_sort radiation reduction during percutaneous coronary intervention: a new protocol with a low frame rate and selective fluoroscopic image storage
topic 3400
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5627824/
https://www.ncbi.nlm.nih.gov/pubmed/28746198
http://dx.doi.org/10.1097/MD.0000000000007517
work_keys_str_mv AT chonminku radiationreductionduringpercutaneouscoronaryinterventionanewprotocolwithalowframerateandselectivefluoroscopicimagestorage
AT chunkookjin radiationreductionduringpercutaneouscoronaryinterventionanewprotocolwithalowframerateandselectivefluoroscopicimagestorage
AT leedaesung radiationreductionduringpercutaneouscoronaryinterventionanewprotocolwithalowframerateandselectivefluoroscopicimagestorage
AT leesooyong radiationreductionduringpercutaneouscoronaryinterventionanewprotocolwithalowframerateandselectivefluoroscopicimagestorage
AT hwangjongmin radiationreductionduringpercutaneouscoronaryinterventionanewprotocolwithalowframerateandselectivefluoroscopicimagestorage
AT leesanghyun radiationreductionduringpercutaneouscoronaryinterventionanewprotocolwithalowframerateandselectivefluoroscopicimagestorage
AT hwangkiwon radiationreductionduringpercutaneouscoronaryinterventionanewprotocolwithalowframerateandselectivefluoroscopicimagestorage
AT kimjeongsu radiationreductionduringpercutaneouscoronaryinterventionanewprotocolwithalowframerateandselectivefluoroscopicimagestorage
AT parkyounghuyn radiationreductionduringpercutaneouscoronaryinterventionanewprotocolwithalowframerateandselectivefluoroscopicimagestorage
AT kimjunehong radiationreductionduringpercutaneouscoronaryinterventionanewprotocolwithalowframerateandselectivefluoroscopicimagestorage