Cargando…

P300: Waves Identification with and without Subtraction of Traces

Introduction  The P300 test requires well-defined and unique criteria, in addition to training for the examiners, for a uniform analysis of studies and to avoid variations and errors in the interpretation of measurement results. Objectives  The objective of this study is to verify whether there are...

Descripción completa

Detalles Bibliográficos
Autores principales: Romero, Ana Carla Leite, Reis, Ana Cláudia Mirândola Barbosa, Oliveira, Anna Caroline Silva de, Oliveira Simões, Humberto de, Oliveira Junqueira, Cinthia Amorim de, Frizzo, Ana Cláudia Figueiredo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Thieme Revinter Publicações Ltda 2017
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5629085/
https://www.ncbi.nlm.nih.gov/pubmed/29018497
http://dx.doi.org/10.1055/s-0037-1599096
_version_ 1783268998488522752
author Romero, Ana Carla Leite
Reis, Ana Cláudia Mirândola Barbosa
Oliveira, Anna Caroline Silva de
Oliveira Simões, Humberto de
Oliveira Junqueira, Cinthia Amorim de
Frizzo, Ana Cláudia Figueiredo
author_facet Romero, Ana Carla Leite
Reis, Ana Cláudia Mirândola Barbosa
Oliveira, Anna Caroline Silva de
Oliveira Simões, Humberto de
Oliveira Junqueira, Cinthia Amorim de
Frizzo, Ana Cláudia Figueiredo
author_sort Romero, Ana Carla Leite
collection PubMed
description Introduction  The P300 test requires well-defined and unique criteria, in addition to training for the examiners, for a uniform analysis of studies and to avoid variations and errors in the interpretation of measurement results. Objectives  The objective of this study is to verify whether there are differences in P300 with and without subtraction of traces of standard and nonstandard stimuli. Method  We conducted this study in collaboration with two research electrophysiology laboratories. From Laboratory 1, we selected 40 tests of subjects between 7–44 years, from Laboratory 2, we selected 83 tests of subjects between 18–44 years. We first performed the identification with the nonstandard stimuli; then, we subtracted the nonstandard stimuli from the standard stimuli. The examiners identified the waves, performing a descriptive and comparative analysis of traces with and without subtraction. Results  After a comparative analysis of the traces with and without subtraction, there was no significant difference when compared with analysis of traces in both laboratories, within the conditions, of right ears ( p  = 0.13 and 0.28 for differences between latency and amplitude measurements) and left ears ( p  = 0.15 and 0.09 for differences between latency and amplitude measurements) from Laboratory 1. As for Laboratory 2, when investigating both ears, results did not identify significant differences ( p  = 0.098 and 0.28 for differences between latency and amplitude measurements). Conclusion  There was no difference verified in traces with and without subtraction. We suggest the identification of this potential performed through nonstandard stimuli.
format Online
Article
Text
id pubmed-5629085
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Thieme Revinter Publicações Ltda
record_format MEDLINE/PubMed
spelling pubmed-56290852017-10-10 P300: Waves Identification with and without Subtraction of Traces Romero, Ana Carla Leite Reis, Ana Cláudia Mirândola Barbosa Oliveira, Anna Caroline Silva de Oliveira Simões, Humberto de Oliveira Junqueira, Cinthia Amorim de Frizzo, Ana Cláudia Figueiredo Int Arch Otorhinolaryngol Introduction  The P300 test requires well-defined and unique criteria, in addition to training for the examiners, for a uniform analysis of studies and to avoid variations and errors in the interpretation of measurement results. Objectives  The objective of this study is to verify whether there are differences in P300 with and without subtraction of traces of standard and nonstandard stimuli. Method  We conducted this study in collaboration with two research electrophysiology laboratories. From Laboratory 1, we selected 40 tests of subjects between 7–44 years, from Laboratory 2, we selected 83 tests of subjects between 18–44 years. We first performed the identification with the nonstandard stimuli; then, we subtracted the nonstandard stimuli from the standard stimuli. The examiners identified the waves, performing a descriptive and comparative analysis of traces with and without subtraction. Results  After a comparative analysis of the traces with and without subtraction, there was no significant difference when compared with analysis of traces in both laboratories, within the conditions, of right ears ( p  = 0.13 and 0.28 for differences between latency and amplitude measurements) and left ears ( p  = 0.15 and 0.09 for differences between latency and amplitude measurements) from Laboratory 1. As for Laboratory 2, when investigating both ears, results did not identify significant differences ( p  = 0.098 and 0.28 for differences between latency and amplitude measurements). Conclusion  There was no difference verified in traces with and without subtraction. We suggest the identification of this potential performed through nonstandard stimuli. Thieme Revinter Publicações Ltda 2017-10 2017-02-28 /pmc/articles/PMC5629085/ /pubmed/29018497 http://dx.doi.org/10.1055/s-0037-1599096 Text en https://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License, which permits unrestricted reproduction and distribution, for non-commercial purposes only; and use and reproduction, but not distribution, of adapted material for non-commercial purposes only, provided the original work is properly cited.
spellingShingle Romero, Ana Carla Leite
Reis, Ana Cláudia Mirândola Barbosa
Oliveira, Anna Caroline Silva de
Oliveira Simões, Humberto de
Oliveira Junqueira, Cinthia Amorim de
Frizzo, Ana Cláudia Figueiredo
P300: Waves Identification with and without Subtraction of Traces
title P300: Waves Identification with and without Subtraction of Traces
title_full P300: Waves Identification with and without Subtraction of Traces
title_fullStr P300: Waves Identification with and without Subtraction of Traces
title_full_unstemmed P300: Waves Identification with and without Subtraction of Traces
title_short P300: Waves Identification with and without Subtraction of Traces
title_sort p300: waves identification with and without subtraction of traces
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5629085/
https://www.ncbi.nlm.nih.gov/pubmed/29018497
http://dx.doi.org/10.1055/s-0037-1599096
work_keys_str_mv AT romeroanacarlaleite p300wavesidentificationwithandwithoutsubtractionoftraces
AT reisanaclaudiamirandolabarbosa p300wavesidentificationwithandwithoutsubtractionoftraces
AT oliveiraannacarolinesilvade p300wavesidentificationwithandwithoutsubtractionoftraces
AT oliveirasimoeshumbertode p300wavesidentificationwithandwithoutsubtractionoftraces
AT oliveirajunqueiracinthiaamorimde p300wavesidentificationwithandwithoutsubtractionoftraces
AT frizzoanaclaudiafigueiredo p300wavesidentificationwithandwithoutsubtractionoftraces