P300: Waves Identification with and without Subtraction of Traces
Introduction The P300 test requires well-defined and unique criteria, in addition to training for the examiners, for a uniform analysis of studies and to avoid variations and errors in the interpretation of measurement results. Objectives The objective of this study is to verify whether there are...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Thieme Revinter Publicações Ltda
2017
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5629085/ https://www.ncbi.nlm.nih.gov/pubmed/29018497 http://dx.doi.org/10.1055/s-0037-1599096 |
_version_ | 1783268998488522752 |
---|---|
author | Romero, Ana Carla Leite Reis, Ana Cláudia Mirândola Barbosa Oliveira, Anna Caroline Silva de Oliveira Simões, Humberto de Oliveira Junqueira, Cinthia Amorim de Frizzo, Ana Cláudia Figueiredo |
author_facet | Romero, Ana Carla Leite Reis, Ana Cláudia Mirândola Barbosa Oliveira, Anna Caroline Silva de Oliveira Simões, Humberto de Oliveira Junqueira, Cinthia Amorim de Frizzo, Ana Cláudia Figueiredo |
author_sort | Romero, Ana Carla Leite |
collection | PubMed |
description | Introduction The P300 test requires well-defined and unique criteria, in addition to training for the examiners, for a uniform analysis of studies and to avoid variations and errors in the interpretation of measurement results. Objectives The objective of this study is to verify whether there are differences in P300 with and without subtraction of traces of standard and nonstandard stimuli. Method We conducted this study in collaboration with two research electrophysiology laboratories. From Laboratory 1, we selected 40 tests of subjects between 7–44 years, from Laboratory 2, we selected 83 tests of subjects between 18–44 years. We first performed the identification with the nonstandard stimuli; then, we subtracted the nonstandard stimuli from the standard stimuli. The examiners identified the waves, performing a descriptive and comparative analysis of traces with and without subtraction. Results After a comparative analysis of the traces with and without subtraction, there was no significant difference when compared with analysis of traces in both laboratories, within the conditions, of right ears ( p = 0.13 and 0.28 for differences between latency and amplitude measurements) and left ears ( p = 0.15 and 0.09 for differences between latency and amplitude measurements) from Laboratory 1. As for Laboratory 2, when investigating both ears, results did not identify significant differences ( p = 0.098 and 0.28 for differences between latency and amplitude measurements). Conclusion There was no difference verified in traces with and without subtraction. We suggest the identification of this potential performed through nonstandard stimuli. |
format | Online Article Text |
id | pubmed-5629085 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Thieme Revinter Publicações Ltda |
record_format | MEDLINE/PubMed |
spelling | pubmed-56290852017-10-10 P300: Waves Identification with and without Subtraction of Traces Romero, Ana Carla Leite Reis, Ana Cláudia Mirândola Barbosa Oliveira, Anna Caroline Silva de Oliveira Simões, Humberto de Oliveira Junqueira, Cinthia Amorim de Frizzo, Ana Cláudia Figueiredo Int Arch Otorhinolaryngol Introduction The P300 test requires well-defined and unique criteria, in addition to training for the examiners, for a uniform analysis of studies and to avoid variations and errors in the interpretation of measurement results. Objectives The objective of this study is to verify whether there are differences in P300 with and without subtraction of traces of standard and nonstandard stimuli. Method We conducted this study in collaboration with two research electrophysiology laboratories. From Laboratory 1, we selected 40 tests of subjects between 7–44 years, from Laboratory 2, we selected 83 tests of subjects between 18–44 years. We first performed the identification with the nonstandard stimuli; then, we subtracted the nonstandard stimuli from the standard stimuli. The examiners identified the waves, performing a descriptive and comparative analysis of traces with and without subtraction. Results After a comparative analysis of the traces with and without subtraction, there was no significant difference when compared with analysis of traces in both laboratories, within the conditions, of right ears ( p = 0.13 and 0.28 for differences between latency and amplitude measurements) and left ears ( p = 0.15 and 0.09 for differences between latency and amplitude measurements) from Laboratory 1. As for Laboratory 2, when investigating both ears, results did not identify significant differences ( p = 0.098 and 0.28 for differences between latency and amplitude measurements). Conclusion There was no difference verified in traces with and without subtraction. We suggest the identification of this potential performed through nonstandard stimuli. Thieme Revinter Publicações Ltda 2017-10 2017-02-28 /pmc/articles/PMC5629085/ /pubmed/29018497 http://dx.doi.org/10.1055/s-0037-1599096 Text en https://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License, which permits unrestricted reproduction and distribution, for non-commercial purposes only; and use and reproduction, but not distribution, of adapted material for non-commercial purposes only, provided the original work is properly cited. |
spellingShingle | Romero, Ana Carla Leite Reis, Ana Cláudia Mirândola Barbosa Oliveira, Anna Caroline Silva de Oliveira Simões, Humberto de Oliveira Junqueira, Cinthia Amorim de Frizzo, Ana Cláudia Figueiredo P300: Waves Identification with and without Subtraction of Traces |
title | P300: Waves Identification with and without Subtraction of Traces |
title_full | P300: Waves Identification with and without Subtraction of Traces |
title_fullStr | P300: Waves Identification with and without Subtraction of Traces |
title_full_unstemmed | P300: Waves Identification with and without Subtraction of Traces |
title_short | P300: Waves Identification with and without Subtraction of Traces |
title_sort | p300: waves identification with and without subtraction of traces |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5629085/ https://www.ncbi.nlm.nih.gov/pubmed/29018497 http://dx.doi.org/10.1055/s-0037-1599096 |
work_keys_str_mv | AT romeroanacarlaleite p300wavesidentificationwithandwithoutsubtractionoftraces AT reisanaclaudiamirandolabarbosa p300wavesidentificationwithandwithoutsubtractionoftraces AT oliveiraannacarolinesilvade p300wavesidentificationwithandwithoutsubtractionoftraces AT oliveirasimoeshumbertode p300wavesidentificationwithandwithoutsubtractionoftraces AT oliveirajunqueiracinthiaamorimde p300wavesidentificationwithandwithoutsubtractionoftraces AT frizzoanaclaudiafigueiredo p300wavesidentificationwithandwithoutsubtractionoftraces |