Cargando…
Correction of collimator-dependent differences in the heart-to-mediastinum ratio in (123)I-metaiodobenzylguanidine cardiac sympathetic imaging: Determination of conversion equations using point-source imaging
BACKGROUND: Septal penetration causes collimator-dependent differences in the heart-to-mediastinum (H/M) ratio in (123)I-metaiodobenzylguanidine (MIBG) cardiac imaging. We investigated generally applicable methods to correct such differences. METHODS AND RESULTS: Four hours after (123)I-MIBG injecti...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer US
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5629249/ https://www.ncbi.nlm.nih.gov/pubmed/27251143 http://dx.doi.org/10.1007/s12350-016-0546-8 |
_version_ | 1783269021040246784 |
---|---|
author | Inoue, Yusuke Abe, Yutaka Kikuchi, Kei Matsunaga, Keiji Masuda, Ray Nishiyama, Kazutoshi |
author_facet | Inoue, Yusuke Abe, Yutaka Kikuchi, Kei Matsunaga, Keiji Masuda, Ray Nishiyama, Kazutoshi |
author_sort | Inoue, Yusuke |
collection | PubMed |
description | BACKGROUND: Septal penetration causes collimator-dependent differences in the heart-to-mediastinum (H/M) ratio in (123)I-metaiodobenzylguanidine (MIBG) cardiac imaging. We investigated generally applicable methods to correct such differences. METHODS AND RESULTS: Four hours after (123)I-MIBG injection, 40 patients underwent anterior chest imaging successively with medium-energy (ME) and various non-ME collimators. The H/M ratios obtained with the non-ME collimators before and after (123)I-dual-window penetration correction were compared with the ME-derived standard values to determine patient-based conversion equations for empiric and combined corrections, respectively. A (123)I point source was imaged with various collimators, and the central ratio, the ratio of count in a small central region of interest to count in a large one, was calculated. The method of predicting the conversion equations from the central ratios was determined. Correction using the patient-based conversion equations removed systematic underestimation of the H/M ratios obtained with the non-ME collimators, and combined correction depressed residual random errors to some degree. Point-source-based equations yielded results comparable to the patient-based equations. CONCLUSIONS: Empiric and combined corrections effectively reduce collimator-dependent differences in the H/M ratio. The conversion equations can be predicted from simple point-source imaging, which would allow to apply these corrections to data obtained with various collimators. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s12350-016-0546-8) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-5629249 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Springer US |
record_format | MEDLINE/PubMed |
spelling | pubmed-56292492017-10-19 Correction of collimator-dependent differences in the heart-to-mediastinum ratio in (123)I-metaiodobenzylguanidine cardiac sympathetic imaging: Determination of conversion equations using point-source imaging Inoue, Yusuke Abe, Yutaka Kikuchi, Kei Matsunaga, Keiji Masuda, Ray Nishiyama, Kazutoshi J Nucl Cardiol Original Article BACKGROUND: Septal penetration causes collimator-dependent differences in the heart-to-mediastinum (H/M) ratio in (123)I-metaiodobenzylguanidine (MIBG) cardiac imaging. We investigated generally applicable methods to correct such differences. METHODS AND RESULTS: Four hours after (123)I-MIBG injection, 40 patients underwent anterior chest imaging successively with medium-energy (ME) and various non-ME collimators. The H/M ratios obtained with the non-ME collimators before and after (123)I-dual-window penetration correction were compared with the ME-derived standard values to determine patient-based conversion equations for empiric and combined corrections, respectively. A (123)I point source was imaged with various collimators, and the central ratio, the ratio of count in a small central region of interest to count in a large one, was calculated. The method of predicting the conversion equations from the central ratios was determined. Correction using the patient-based conversion equations removed systematic underestimation of the H/M ratios obtained with the non-ME collimators, and combined correction depressed residual random errors to some degree. Point-source-based equations yielded results comparable to the patient-based equations. CONCLUSIONS: Empiric and combined corrections effectively reduce collimator-dependent differences in the H/M ratio. The conversion equations can be predicted from simple point-source imaging, which would allow to apply these corrections to data obtained with various collimators. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s12350-016-0546-8) contains supplementary material, which is available to authorized users. Springer US 2016-06-01 2017 /pmc/articles/PMC5629249/ /pubmed/27251143 http://dx.doi.org/10.1007/s12350-016-0546-8 Text en © The Author(s) 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Original Article Inoue, Yusuke Abe, Yutaka Kikuchi, Kei Matsunaga, Keiji Masuda, Ray Nishiyama, Kazutoshi Correction of collimator-dependent differences in the heart-to-mediastinum ratio in (123)I-metaiodobenzylguanidine cardiac sympathetic imaging: Determination of conversion equations using point-source imaging |
title | Correction of collimator-dependent differences in the heart-to-mediastinum ratio in (123)I-metaiodobenzylguanidine cardiac sympathetic imaging: Determination of conversion equations using point-source imaging |
title_full | Correction of collimator-dependent differences in the heart-to-mediastinum ratio in (123)I-metaiodobenzylguanidine cardiac sympathetic imaging: Determination of conversion equations using point-source imaging |
title_fullStr | Correction of collimator-dependent differences in the heart-to-mediastinum ratio in (123)I-metaiodobenzylguanidine cardiac sympathetic imaging: Determination of conversion equations using point-source imaging |
title_full_unstemmed | Correction of collimator-dependent differences in the heart-to-mediastinum ratio in (123)I-metaiodobenzylguanidine cardiac sympathetic imaging: Determination of conversion equations using point-source imaging |
title_short | Correction of collimator-dependent differences in the heart-to-mediastinum ratio in (123)I-metaiodobenzylguanidine cardiac sympathetic imaging: Determination of conversion equations using point-source imaging |
title_sort | correction of collimator-dependent differences in the heart-to-mediastinum ratio in (123)i-metaiodobenzylguanidine cardiac sympathetic imaging: determination of conversion equations using point-source imaging |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5629249/ https://www.ncbi.nlm.nih.gov/pubmed/27251143 http://dx.doi.org/10.1007/s12350-016-0546-8 |
work_keys_str_mv | AT inoueyusuke correctionofcollimatordependentdifferencesinthehearttomediastinumratioin123imetaiodobenzylguanidinecardiacsympatheticimagingdeterminationofconversionequationsusingpointsourceimaging AT abeyutaka correctionofcollimatordependentdifferencesinthehearttomediastinumratioin123imetaiodobenzylguanidinecardiacsympatheticimagingdeterminationofconversionequationsusingpointsourceimaging AT kikuchikei correctionofcollimatordependentdifferencesinthehearttomediastinumratioin123imetaiodobenzylguanidinecardiacsympatheticimagingdeterminationofconversionequationsusingpointsourceimaging AT matsunagakeiji correctionofcollimatordependentdifferencesinthehearttomediastinumratioin123imetaiodobenzylguanidinecardiacsympatheticimagingdeterminationofconversionequationsusingpointsourceimaging AT masudaray correctionofcollimatordependentdifferencesinthehearttomediastinumratioin123imetaiodobenzylguanidinecardiacsympatheticimagingdeterminationofconversionequationsusingpointsourceimaging AT nishiyamakazutoshi correctionofcollimatordependentdifferencesinthehearttomediastinumratioin123imetaiodobenzylguanidinecardiacsympatheticimagingdeterminationofconversionequationsusingpointsourceimaging |