Cargando…

Antibiotic-laden Arthroplasty with a Novel Design of Cement Mould and Metallic Endoskeleton for Treatment of Hip Infection, an Inexpensive Alternative: A Preliminary Report of Two Cases

Infection of the hip after implant fixation is an uncommon yet devastating complication that results in poor long-term outcome. The gold standard treatment for chronic infection after hip arthroplasty is a two-stage protocol: eradication of infection, follow by re-implantation arthroplasty. The use...

Descripción completa

Detalles Bibliográficos
Autores principales: William, CCH, Simmrat, S, Suhaeb, AM
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Malaysian Orthopaedic Association 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5630058/
https://www.ncbi.nlm.nih.gov/pubmed/29021886
http://dx.doi.org/10.5704/MOJ.1707.015
_version_ 1783269167612297216
author William, CCH
Simmrat, S
Suhaeb, AM
author_facet William, CCH
Simmrat, S
Suhaeb, AM
author_sort William, CCH
collection PubMed
description Infection of the hip after implant fixation is an uncommon yet devastating complication that results in poor long-term outcome. The gold standard treatment for chronic infection after hip arthroplasty is a two-stage protocol: eradication of infection, follow by re-implantation arthroplasty. The use of interim antibiotic-laden cement spacer has become a popular procedure to maintain hip joint function and provide antibiotic elution simultaneously before re-implantation. However, antibiotic cement spacer is mechanically weak and breaks if overloaded. Therefore, we designed a cement mould with metallic endoskeleton with the aim of creating a stronger, inexpensive, antibiotic-impregnated spacer resembling a unipolar arthroplasty. We report two cases of severe hip joint infection after implant fixation (bipolar hemiarthroplasty, screw fixation neck of femur). Both patients had undergone first stage surgery of debridement and articulating antibiotic cement insertion using our design. Although the second stage surgery was planned for these patients, both patients delayed the operation in view of good functional status after a year walking with the antibiotic cement spacer. These cases showed that the mechanical property of the new antibiotic cement spacer was promising but further mechanical studies upon this new endoskeleton design are required.
format Online
Article
Text
id pubmed-5630058
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Malaysian Orthopaedic Association
record_format MEDLINE/PubMed
spelling pubmed-56300582017-10-11 Antibiotic-laden Arthroplasty with a Novel Design of Cement Mould and Metallic Endoskeleton for Treatment of Hip Infection, an Inexpensive Alternative: A Preliminary Report of Two Cases William, CCH Simmrat, S Suhaeb, AM Malays Orthop J Original Article Infection of the hip after implant fixation is an uncommon yet devastating complication that results in poor long-term outcome. The gold standard treatment for chronic infection after hip arthroplasty is a two-stage protocol: eradication of infection, follow by re-implantation arthroplasty. The use of interim antibiotic-laden cement spacer has become a popular procedure to maintain hip joint function and provide antibiotic elution simultaneously before re-implantation. However, antibiotic cement spacer is mechanically weak and breaks if overloaded. Therefore, we designed a cement mould with metallic endoskeleton with the aim of creating a stronger, inexpensive, antibiotic-impregnated spacer resembling a unipolar arthroplasty. We report two cases of severe hip joint infection after implant fixation (bipolar hemiarthroplasty, screw fixation neck of femur). Both patients had undergone first stage surgery of debridement and articulating antibiotic cement insertion using our design. Although the second stage surgery was planned for these patients, both patients delayed the operation in view of good functional status after a year walking with the antibiotic cement spacer. These cases showed that the mechanical property of the new antibiotic cement spacer was promising but further mechanical studies upon this new endoskeleton design are required. Malaysian Orthopaedic Association 2017-07 /pmc/articles/PMC5630058/ /pubmed/29021886 http://dx.doi.org/10.5704/MOJ.1707.015 Text en © 2017 Malaysian Orthopaedic Association (MOA). All Rights Reserved http://creativecommons.org/licenses/by/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited
spellingShingle Original Article
William, CCH
Simmrat, S
Suhaeb, AM
Antibiotic-laden Arthroplasty with a Novel Design of Cement Mould and Metallic Endoskeleton for Treatment of Hip Infection, an Inexpensive Alternative: A Preliminary Report of Two Cases
title Antibiotic-laden Arthroplasty with a Novel Design of Cement Mould and Metallic Endoskeleton for Treatment of Hip Infection, an Inexpensive Alternative: A Preliminary Report of Two Cases
title_full Antibiotic-laden Arthroplasty with a Novel Design of Cement Mould and Metallic Endoskeleton for Treatment of Hip Infection, an Inexpensive Alternative: A Preliminary Report of Two Cases
title_fullStr Antibiotic-laden Arthroplasty with a Novel Design of Cement Mould and Metallic Endoskeleton for Treatment of Hip Infection, an Inexpensive Alternative: A Preliminary Report of Two Cases
title_full_unstemmed Antibiotic-laden Arthroplasty with a Novel Design of Cement Mould and Metallic Endoskeleton for Treatment of Hip Infection, an Inexpensive Alternative: A Preliminary Report of Two Cases
title_short Antibiotic-laden Arthroplasty with a Novel Design of Cement Mould and Metallic Endoskeleton for Treatment of Hip Infection, an Inexpensive Alternative: A Preliminary Report of Two Cases
title_sort antibiotic-laden arthroplasty with a novel design of cement mould and metallic endoskeleton for treatment of hip infection, an inexpensive alternative: a preliminary report of two cases
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5630058/
https://www.ncbi.nlm.nih.gov/pubmed/29021886
http://dx.doi.org/10.5704/MOJ.1707.015
work_keys_str_mv AT williamcch antibioticladenarthroplastywithanoveldesignofcementmouldandmetallicendoskeletonfortreatmentofhipinfectionaninexpensivealternativeapreliminaryreportoftwocases
AT simmrats antibioticladenarthroplastywithanoveldesignofcementmouldandmetallicendoskeletonfortreatmentofhipinfectionaninexpensivealternativeapreliminaryreportoftwocases
AT suhaebam antibioticladenarthroplastywithanoveldesignofcementmouldandmetallicendoskeletonfortreatmentofhipinfectionaninexpensivealternativeapreliminaryreportoftwocases