Catheter-related Complications and Potential Risk Factors Among Catheterized Cancer Patients Receiving Parenteral Nutrition at The University of Texas MD Anderson Cancer Center: A 26,000 Parenteral Nutrition-day Experience

BACKGROUND: Parenteral nutrition (PN) is used as nutritional support in patients that are malnourished, critically ill, and/or have a nonfunctional gut. Patients receiving PN are at increased risk for both infectious and noninfectious catheter complications often leading to increased morbidity and m...

Descripción completa

Detalles Bibliográficos
Autores principales: Reitzel, Ruth, Chaftari, Anne-Marie, Feldman, Adina, Numan, Laith, Hachem, Ray Y, Rosenblatt, Joel, Raad, Issam
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5631547/
http://dx.doi.org/10.1093/ofid/ofx163.1683
_version_ 1783269499253817344
author Reitzel, Ruth
Chaftari, Anne-Marie
Feldman, Adina
Numan, Laith
Hachem, Ray Y
Rosenblatt, Joel
Raad, Issam
author_facet Reitzel, Ruth
Chaftari, Anne-Marie
Feldman, Adina
Numan, Laith
Hachem, Ray Y
Rosenblatt, Joel
Raad, Issam
author_sort Reitzel, Ruth
collection PubMed
description BACKGROUND: Parenteral nutrition (PN) is used as nutritional support in patients that are malnourished, critically ill, and/or have a nonfunctional gut. Patients receiving PN are at increased risk for both infectious and noninfectious catheter complications often leading to increased morbidity and mortality. Risk factors for catheter complications in patients receiving PN are often variable and poorly understood. METHODS: We conducted retrospective study among cancer patients who received PN between January 1, 2013 and December 31, 2015 at the University of Texas MD Anderson Cancer Center. Rate and prevalence of central line associated blood stream infection (CLABSI) and noninfectious catheter complications were assessed. Additionally, prevalence and time-to-infection of causative pathogens were evaluated. Multivariate logistic regression analyses were conducted in a sample of the PN population to identify risk factors for both infectious and noninfectious catheter complications. RESULTS: We identified 46 CLABSI cases in 38 patients of the 1,762 patients receiving PN (1.73 episodes of CLABSI per 1000 PN days). Gram-positives (37.84%) and yeast (29.73%) were the most common pathogens, with catheter-related Candidemias occurring earlier than gram-positive or gram-negative CLABSI. Noninfectious catheter complications occurred in 56 patients (38.6%). Multivariate analysis identified age, GVHD, and history of occlusion in the same catheter, as well as intestinal failure and long-term PN use as significant risk factors for CLABSI and noninfectious catheter complications, respectively. CONCLUSION: Patients receiving PN are at higher risk for both infectious and noninfectious catheter complications. Compared with national averages of CLABSI, the prevalence of catheter-related Candidemias in the PN cancer patient population was increased. This study highlights the need for development of more effective targeted preventative interventions. DISCLOSURES: J. Rosenblatt, Infective Technologies, LLC: Co-Inventor of the Nitroglycerin-Citrate-Ethanol catheter lock solution technology which is owned by the University of Texas MD Anderson Cancer Center (UTMDACC) and has been licensed by Novel Anti-Infective Technologies, LLC in which Dr. Rosenblatt is a and Shareholder, Licensing agreement or royalty; UT MD Anderson Cancer Center: Co-Inventor of the Nitroglycerin-Citrate-Ethanol catheter lock solution technology which is owned by the University of Texas MD Anderson Cancer Center (UTMDACC) and has been licensed by Novel Anti-Infective Technologies, LLC in which Dr. Rosenblatt is a s and Scientific Advisor, Licensing agreement or royalty; I. Raad, Merck: Grant Investigator, Research grant; Allergan: Grant Investigator, Research grant; Infective Technologies, LLC: Co-Inventor of the Nitroglycerin-Citrate-Ethanol catheter lock solution technology which is owned by the University of Texas MD Anderson Cancer Center (UTMDACC) and has been licensed by Novel Anti-Infective Technologies, LLC in which Dr. Raad is a s and Shareholder, Licensing agreement or royalty.
format Online
Article
Text
id pubmed-5631547
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-56315472017-11-07 Catheter-related Complications and Potential Risk Factors Among Catheterized Cancer Patients Receiving Parenteral Nutrition at The University of Texas MD Anderson Cancer Center: A 26,000 Parenteral Nutrition-day Experience Reitzel, Ruth Chaftari, Anne-Marie Feldman, Adina Numan, Laith Hachem, Ray Y Rosenblatt, Joel Raad, Issam Open Forum Infect Dis Abstracts BACKGROUND: Parenteral nutrition (PN) is used as nutritional support in patients that are malnourished, critically ill, and/or have a nonfunctional gut. Patients receiving PN are at increased risk for both infectious and noninfectious catheter complications often leading to increased morbidity and mortality. Risk factors for catheter complications in patients receiving PN are often variable and poorly understood. METHODS: We conducted retrospective study among cancer patients who received PN between January 1, 2013 and December 31, 2015 at the University of Texas MD Anderson Cancer Center. Rate and prevalence of central line associated blood stream infection (CLABSI) and noninfectious catheter complications were assessed. Additionally, prevalence and time-to-infection of causative pathogens were evaluated. Multivariate logistic regression analyses were conducted in a sample of the PN population to identify risk factors for both infectious and noninfectious catheter complications. RESULTS: We identified 46 CLABSI cases in 38 patients of the 1,762 patients receiving PN (1.73 episodes of CLABSI per 1000 PN days). Gram-positives (37.84%) and yeast (29.73%) were the most common pathogens, with catheter-related Candidemias occurring earlier than gram-positive or gram-negative CLABSI. Noninfectious catheter complications occurred in 56 patients (38.6%). Multivariate analysis identified age, GVHD, and history of occlusion in the same catheter, as well as intestinal failure and long-term PN use as significant risk factors for CLABSI and noninfectious catheter complications, respectively. CONCLUSION: Patients receiving PN are at higher risk for both infectious and noninfectious catheter complications. Compared with national averages of CLABSI, the prevalence of catheter-related Candidemias in the PN cancer patient population was increased. This study highlights the need for development of more effective targeted preventative interventions. DISCLOSURES: J. Rosenblatt, Infective Technologies, LLC: Co-Inventor of the Nitroglycerin-Citrate-Ethanol catheter lock solution technology which is owned by the University of Texas MD Anderson Cancer Center (UTMDACC) and has been licensed by Novel Anti-Infective Technologies, LLC in which Dr. Rosenblatt is a and Shareholder, Licensing agreement or royalty; UT MD Anderson Cancer Center: Co-Inventor of the Nitroglycerin-Citrate-Ethanol catheter lock solution technology which is owned by the University of Texas MD Anderson Cancer Center (UTMDACC) and has been licensed by Novel Anti-Infective Technologies, LLC in which Dr. Rosenblatt is a s and Scientific Advisor, Licensing agreement or royalty; I. Raad, Merck: Grant Investigator, Research grant; Allergan: Grant Investigator, Research grant; Infective Technologies, LLC: Co-Inventor of the Nitroglycerin-Citrate-Ethanol catheter lock solution technology which is owned by the University of Texas MD Anderson Cancer Center (UTMDACC) and has been licensed by Novel Anti-Infective Technologies, LLC in which Dr. Raad is a s and Shareholder, Licensing agreement or royalty. Oxford University Press 2017-10-04 /pmc/articles/PMC5631547/ http://dx.doi.org/10.1093/ofid/ofx163.1683 Text en © The Author 2017. Published by Oxford University Press on behalf of Infectious Diseases Society of America. http://creativecommons.org/licenses/by-nc-nd/4.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs licence (http://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial reproduction and distribution of the work, in any medium, provided the original work is not altered or transformed in any way, and that the work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Abstracts
Reitzel, Ruth
Chaftari, Anne-Marie
Feldman, Adina
Numan, Laith
Hachem, Ray Y
Rosenblatt, Joel
Raad, Issam
Catheter-related Complications and Potential Risk Factors Among Catheterized Cancer Patients Receiving Parenteral Nutrition at The University of Texas MD Anderson Cancer Center: A 26,000 Parenteral Nutrition-day Experience
title Catheter-related Complications and Potential Risk Factors Among Catheterized Cancer Patients Receiving Parenteral Nutrition at The University of Texas MD Anderson Cancer Center: A 26,000 Parenteral Nutrition-day Experience
title_full Catheter-related Complications and Potential Risk Factors Among Catheterized Cancer Patients Receiving Parenteral Nutrition at The University of Texas MD Anderson Cancer Center: A 26,000 Parenteral Nutrition-day Experience
title_fullStr Catheter-related Complications and Potential Risk Factors Among Catheterized Cancer Patients Receiving Parenteral Nutrition at The University of Texas MD Anderson Cancer Center: A 26,000 Parenteral Nutrition-day Experience
title_full_unstemmed Catheter-related Complications and Potential Risk Factors Among Catheterized Cancer Patients Receiving Parenteral Nutrition at The University of Texas MD Anderson Cancer Center: A 26,000 Parenteral Nutrition-day Experience
title_short Catheter-related Complications and Potential Risk Factors Among Catheterized Cancer Patients Receiving Parenteral Nutrition at The University of Texas MD Anderson Cancer Center: A 26,000 Parenteral Nutrition-day Experience
title_sort catheter-related complications and potential risk factors among catheterized cancer patients receiving parenteral nutrition at the university of texas md anderson cancer center: a 26,000 parenteral nutrition-day experience
topic Abstracts
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5631547/
http://dx.doi.org/10.1093/ofid/ofx163.1683
work_keys_str_mv AT reitzelruth catheterrelatedcomplicationsandpotentialriskfactorsamongcatheterizedcancerpatientsreceivingparenteralnutritionattheuniversityoftexasmdandersoncancercentera26000parenteralnutritiondayexperience
AT chaftariannemarie catheterrelatedcomplicationsandpotentialriskfactorsamongcatheterizedcancerpatientsreceivingparenteralnutritionattheuniversityoftexasmdandersoncancercentera26000parenteralnutritiondayexperience
AT feldmanadina catheterrelatedcomplicationsandpotentialriskfactorsamongcatheterizedcancerpatientsreceivingparenteralnutritionattheuniversityoftexasmdandersoncancercentera26000parenteralnutritiondayexperience
AT numanlaith catheterrelatedcomplicationsandpotentialriskfactorsamongcatheterizedcancerpatientsreceivingparenteralnutritionattheuniversityoftexasmdandersoncancercentera26000parenteralnutritiondayexperience
AT hachemrayy catheterrelatedcomplicationsandpotentialriskfactorsamongcatheterizedcancerpatientsreceivingparenteralnutritionattheuniversityoftexasmdandersoncancercentera26000parenteralnutritiondayexperience
AT rosenblattjoel catheterrelatedcomplicationsandpotentialriskfactorsamongcatheterizedcancerpatientsreceivingparenteralnutritionattheuniversityoftexasmdandersoncancercentera26000parenteralnutritiondayexperience
AT raadissam catheterrelatedcomplicationsandpotentialriskfactorsamongcatheterizedcancerpatientsreceivingparenteralnutritionattheuniversityoftexasmdandersoncancercentera26000parenteralnutritiondayexperience