Cargando…
Comparison of the Feasibility and Safety of First- versus Second-Generation AMPLATZER™ Occluders for Left Atrial Appendage Closure
INTRODUCTION: Left atrial appendage closure (LAAC) is considered an alternative to oral anticoagulation therapy in patients with atrial fibrillation (AF). The aim of this study was to compare the safety and efficacy of the first- and second-generation AMPLATZER Devices for LAAC, AMPLATZER Cardiac Pl...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5632477/ https://www.ncbi.nlm.nih.gov/pubmed/29085833 http://dx.doi.org/10.1155/2017/1519362 |
_version_ | 1783269713166467072 |
---|---|
author | Al-Kassou, Baravan Omran, Heyder |
author_facet | Al-Kassou, Baravan Omran, Heyder |
author_sort | Al-Kassou, Baravan |
collection | PubMed |
description | INTRODUCTION: Left atrial appendage closure (LAAC) is considered an alternative to oral anticoagulation therapy in patients with atrial fibrillation (AF). The aim of this study was to compare the safety and efficacy of the first- and second-generation AMPLATZER Devices for LAAC, AMPLATZER Cardiac Plug (ACP) versus AMPLATZER Amulet™. METHODS: Procedural data, such as fluoroscopy time, radiation dose, and contrast-dye, as well as VARC criteria and major adverse events (MAEs) were assessed for both devices. The rate of peridevice leaks was analyzed at echocardiographic follow-up. RESULTS: A total of 196 patients with AF underwent LAAC with the ACP (n = 99) or Amulet device (n = 97). The use of Amulet was associated with significantly lower fluoroscopy time (14.8 ± 7.4 min versus 10.6 ± 4.1 min; p < 0.001), lower radiation dose (4833 ± 3360 cGy⁎cm(2) versus 3206 ± 2169 cGy⁎cm(2); p < 0.001), and reduced amount of contrast-dye (150.2 ± 83.9 ml versus 128.8 ± 46.0 ml; p = 0.03). Furthermore, LAAC with Amulet devices resulted in lower device-resizing rates (3 versus 16 cases; p = 0.001). Peridevice leaks were less frequent in the Amulet group (12 versus 4; p = 0.03). MAE occurred in 6 ACP and 4 Amulet patients (p = 0.58). CONCLUSIONS: The Amulet device is associated with shorter fluoroscopy times and radiation dosages, reduced use of contrast-dye, lower recapture rates, and less peridevice leaks as compared to the ACP. |
format | Online Article Text |
id | pubmed-5632477 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-56324772017-10-30 Comparison of the Feasibility and Safety of First- versus Second-Generation AMPLATZER™ Occluders for Left Atrial Appendage Closure Al-Kassou, Baravan Omran, Heyder Biomed Res Int Research Article INTRODUCTION: Left atrial appendage closure (LAAC) is considered an alternative to oral anticoagulation therapy in patients with atrial fibrillation (AF). The aim of this study was to compare the safety and efficacy of the first- and second-generation AMPLATZER Devices for LAAC, AMPLATZER Cardiac Plug (ACP) versus AMPLATZER Amulet™. METHODS: Procedural data, such as fluoroscopy time, radiation dose, and contrast-dye, as well as VARC criteria and major adverse events (MAEs) were assessed for both devices. The rate of peridevice leaks was analyzed at echocardiographic follow-up. RESULTS: A total of 196 patients with AF underwent LAAC with the ACP (n = 99) or Amulet device (n = 97). The use of Amulet was associated with significantly lower fluoroscopy time (14.8 ± 7.4 min versus 10.6 ± 4.1 min; p < 0.001), lower radiation dose (4833 ± 3360 cGy⁎cm(2) versus 3206 ± 2169 cGy⁎cm(2); p < 0.001), and reduced amount of contrast-dye (150.2 ± 83.9 ml versus 128.8 ± 46.0 ml; p = 0.03). Furthermore, LAAC with Amulet devices resulted in lower device-resizing rates (3 versus 16 cases; p = 0.001). Peridevice leaks were less frequent in the Amulet group (12 versus 4; p = 0.03). MAE occurred in 6 ACP and 4 Amulet patients (p = 0.58). CONCLUSIONS: The Amulet device is associated with shorter fluoroscopy times and radiation dosages, reduced use of contrast-dye, lower recapture rates, and less peridevice leaks as compared to the ACP. Hindawi 2017 2017-09-20 /pmc/articles/PMC5632477/ /pubmed/29085833 http://dx.doi.org/10.1155/2017/1519362 Text en Copyright © 2017 Baravan Al-Kassou and Heyder Omran. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Al-Kassou, Baravan Omran, Heyder Comparison of the Feasibility and Safety of First- versus Second-Generation AMPLATZER™ Occluders for Left Atrial Appendage Closure |
title | Comparison of the Feasibility and Safety of First- versus Second-Generation AMPLATZER™ Occluders for Left Atrial Appendage Closure |
title_full | Comparison of the Feasibility and Safety of First- versus Second-Generation AMPLATZER™ Occluders for Left Atrial Appendage Closure |
title_fullStr | Comparison of the Feasibility and Safety of First- versus Second-Generation AMPLATZER™ Occluders for Left Atrial Appendage Closure |
title_full_unstemmed | Comparison of the Feasibility and Safety of First- versus Second-Generation AMPLATZER™ Occluders for Left Atrial Appendage Closure |
title_short | Comparison of the Feasibility and Safety of First- versus Second-Generation AMPLATZER™ Occluders for Left Atrial Appendage Closure |
title_sort | comparison of the feasibility and safety of first- versus second-generation amplatzer™ occluders for left atrial appendage closure |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5632477/ https://www.ncbi.nlm.nih.gov/pubmed/29085833 http://dx.doi.org/10.1155/2017/1519362 |
work_keys_str_mv | AT alkassoubaravan comparisonofthefeasibilityandsafetyoffirstversussecondgenerationamplatzeroccludersforleftatrialappendageclosure AT omranheyder comparisonofthefeasibilityandsafetyoffirstversussecondgenerationamplatzeroccludersforleftatrialappendageclosure |