Cargando…

High-Throughput Testing of Urogenital and Extragenital Specimens for Detection of Chlamydia Trachomatis and Neisseria Gonorrhoeae with Cobas(®) CT/NG

We compared the analytical and clinical performance of cobas(®) CT/NG for use on the Cobas(®) 6800/8800 Systems with the Cobas(®) 4800 CT/NG Test from urogenital and extragenital specimens in over 12,000 specimens from both male and female subjects in Germany and the United States. The analytical se...

Descripción completa

Detalles Bibliográficos
Autores principales: Marlowe, Elizabeth M., Hardy, David, Krevolin, Mark, Gohl, Peter, Bertram, Alexander, Arcenas, Rodney, Seiverth, Britta, Schneider, Tanja, Liesenfeld, Oliver
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Akadémiai Kiadó 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5632745/
https://www.ncbi.nlm.nih.gov/pubmed/29034107
http://dx.doi.org/10.1556/1886.2017.00018
_version_ 1783269756635185152
author Marlowe, Elizabeth M.
Hardy, David
Krevolin, Mark
Gohl, Peter
Bertram, Alexander
Arcenas, Rodney
Seiverth, Britta
Schneider, Tanja
Liesenfeld, Oliver
author_facet Marlowe, Elizabeth M.
Hardy, David
Krevolin, Mark
Gohl, Peter
Bertram, Alexander
Arcenas, Rodney
Seiverth, Britta
Schneider, Tanja
Liesenfeld, Oliver
author_sort Marlowe, Elizabeth M.
collection PubMed
description We compared the analytical and clinical performance of cobas(®) CT/NG for use on the Cobas(®) 6800/8800 Systems with the Cobas(®) 4800 CT/NG Test from urogenital and extragenital specimens in over 12,000 specimens from both male and female subjects in Germany and the United States. The analytical sensitivity was ≤40 EB/ml for Chlamydia trachomatis (CT) and ≤1 CFU/ml for Neisseria gonorrhoeae (NG). Using clinical specimens, the overall percent agreement with the Cobas(®) 4800 CT/NG Test was >98.5%. Across urogenital specimens, there were 93 discrepant specimens; 76 (93.8%) of 81 CT discrepant specimens were 6800+/4800– and 10 (83.3%) of 12 NG discrepant specimens were 6800+/4800–. Sequencing verified CT results for 45 (61.6%) of 73 samples positive by 6800 and 1 (20%) of 5 positive by 4800. Similarly, 7 (70.0%) of 10 NG samples positive by 6800 and 1 of 2 positive by 4800 were confirmed by sequencing. Among discrepant extragenital specimens (all 6800+/4800–), 7 (50%) of 14 oropharyngeal and 23 (76.7%) of 30 anorectal CT discordant samples were confirmed as CT positive by sequencing; all 8 anorectal and 20 (90.9%) of 22 oropharyngeal NG discordant results were also confirmed as NG positive. In conclusion, Cobas(®) CT/NG for use on the Cobas(®) 6800/8800 Systems provides high-throughput automated solutions for sexually transmitted infection (STI) screening programs.
format Online
Article
Text
id pubmed-5632745
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Akadémiai Kiadó
record_format MEDLINE/PubMed
spelling pubmed-56327452017-10-13 High-Throughput Testing of Urogenital and Extragenital Specimens for Detection of Chlamydia Trachomatis and Neisseria Gonorrhoeae with Cobas(®) CT/NG Marlowe, Elizabeth M. Hardy, David Krevolin, Mark Gohl, Peter Bertram, Alexander Arcenas, Rodney Seiverth, Britta Schneider, Tanja Liesenfeld, Oliver Eur J Microbiol Immunol (Bp) Original Article We compared the analytical and clinical performance of cobas(®) CT/NG for use on the Cobas(®) 6800/8800 Systems with the Cobas(®) 4800 CT/NG Test from urogenital and extragenital specimens in over 12,000 specimens from both male and female subjects in Germany and the United States. The analytical sensitivity was ≤40 EB/ml for Chlamydia trachomatis (CT) and ≤1 CFU/ml for Neisseria gonorrhoeae (NG). Using clinical specimens, the overall percent agreement with the Cobas(®) 4800 CT/NG Test was >98.5%. Across urogenital specimens, there were 93 discrepant specimens; 76 (93.8%) of 81 CT discrepant specimens were 6800+/4800– and 10 (83.3%) of 12 NG discrepant specimens were 6800+/4800–. Sequencing verified CT results for 45 (61.6%) of 73 samples positive by 6800 and 1 (20%) of 5 positive by 4800. Similarly, 7 (70.0%) of 10 NG samples positive by 6800 and 1 of 2 positive by 4800 were confirmed by sequencing. Among discrepant extragenital specimens (all 6800+/4800–), 7 (50%) of 14 oropharyngeal and 23 (76.7%) of 30 anorectal CT discordant samples were confirmed as CT positive by sequencing; all 8 anorectal and 20 (90.9%) of 22 oropharyngeal NG discordant results were also confirmed as NG positive. In conclusion, Cobas(®) CT/NG for use on the Cobas(®) 6800/8800 Systems provides high-throughput automated solutions for sexually transmitted infection (STI) screening programs. Akadémiai Kiadó 2017-09-11 /pmc/articles/PMC5632745/ /pubmed/29034107 http://dx.doi.org/10.1556/1886.2017.00018 Text en © 2017, The Author(s) http://creativecommons.org/licenses/by-nc/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (https://creativecommons.org/licenses/by-nc/4.0/), which permits unrestricted use, distribution, and reproduction in any medium for non-commercial purposes, provided the original author and source are credited, a link to the CC License is provided, and changes – if any – are indicated.
spellingShingle Original Article
Marlowe, Elizabeth M.
Hardy, David
Krevolin, Mark
Gohl, Peter
Bertram, Alexander
Arcenas, Rodney
Seiverth, Britta
Schneider, Tanja
Liesenfeld, Oliver
High-Throughput Testing of Urogenital and Extragenital Specimens for Detection of Chlamydia Trachomatis and Neisseria Gonorrhoeae with Cobas(®) CT/NG
title High-Throughput Testing of Urogenital and Extragenital Specimens for Detection of Chlamydia Trachomatis and Neisseria Gonorrhoeae with Cobas(®) CT/NG
title_full High-Throughput Testing of Urogenital and Extragenital Specimens for Detection of Chlamydia Trachomatis and Neisseria Gonorrhoeae with Cobas(®) CT/NG
title_fullStr High-Throughput Testing of Urogenital and Extragenital Specimens for Detection of Chlamydia Trachomatis and Neisseria Gonorrhoeae with Cobas(®) CT/NG
title_full_unstemmed High-Throughput Testing of Urogenital and Extragenital Specimens for Detection of Chlamydia Trachomatis and Neisseria Gonorrhoeae with Cobas(®) CT/NG
title_short High-Throughput Testing of Urogenital and Extragenital Specimens for Detection of Chlamydia Trachomatis and Neisseria Gonorrhoeae with Cobas(®) CT/NG
title_sort high-throughput testing of urogenital and extragenital specimens for detection of chlamydia trachomatis and neisseria gonorrhoeae with cobas(®) ct/ng
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5632745/
https://www.ncbi.nlm.nih.gov/pubmed/29034107
http://dx.doi.org/10.1556/1886.2017.00018
work_keys_str_mv AT marloweelizabethm highthroughputtestingofurogenitalandextragenitalspecimensfordetectionofchlamydiatrachomatisandneisseriagonorrhoeaewithcobasctng
AT hardydavid highthroughputtestingofurogenitalandextragenitalspecimensfordetectionofchlamydiatrachomatisandneisseriagonorrhoeaewithcobasctng
AT krevolinmark highthroughputtestingofurogenitalandextragenitalspecimensfordetectionofchlamydiatrachomatisandneisseriagonorrhoeaewithcobasctng
AT gohlpeter highthroughputtestingofurogenitalandextragenitalspecimensfordetectionofchlamydiatrachomatisandneisseriagonorrhoeaewithcobasctng
AT bertramalexander highthroughputtestingofurogenitalandextragenitalspecimensfordetectionofchlamydiatrachomatisandneisseriagonorrhoeaewithcobasctng
AT arcenasrodney highthroughputtestingofurogenitalandextragenitalspecimensfordetectionofchlamydiatrachomatisandneisseriagonorrhoeaewithcobasctng
AT seiverthbritta highthroughputtestingofurogenitalandextragenitalspecimensfordetectionofchlamydiatrachomatisandneisseriagonorrhoeaewithcobasctng
AT schneidertanja highthroughputtestingofurogenitalandextragenitalspecimensfordetectionofchlamydiatrachomatisandneisseriagonorrhoeaewithcobasctng
AT liesenfeldoliver highthroughputtestingofurogenitalandextragenitalspecimensfordetectionofchlamydiatrachomatisandneisseriagonorrhoeaewithcobasctng