High-Throughput Testing of Urogenital and Extragenital Specimens for Detection of Chlamydia Trachomatis and Neisseria Gonorrhoeae with Cobas(®) CT/NG
We compared the analytical and clinical performance of cobas(®) CT/NG for use on the Cobas(®) 6800/8800 Systems with the Cobas(®) 4800 CT/NG Test from urogenital and extragenital specimens in over 12,000 specimens from both male and female subjects in Germany and the United States. The analytical se...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Akadémiai Kiadó
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5632745/ https://www.ncbi.nlm.nih.gov/pubmed/29034107 http://dx.doi.org/10.1556/1886.2017.00018 |
_version_ | 1783269756635185152 |
---|---|
author | Marlowe, Elizabeth M. Hardy, David Krevolin, Mark Gohl, Peter Bertram, Alexander Arcenas, Rodney Seiverth, Britta Schneider, Tanja Liesenfeld, Oliver |
author_facet | Marlowe, Elizabeth M. Hardy, David Krevolin, Mark Gohl, Peter Bertram, Alexander Arcenas, Rodney Seiverth, Britta Schneider, Tanja Liesenfeld, Oliver |
author_sort | Marlowe, Elizabeth M. |
collection | PubMed |
description | We compared the analytical and clinical performance of cobas(®) CT/NG for use on the Cobas(®) 6800/8800 Systems with the Cobas(®) 4800 CT/NG Test from urogenital and extragenital specimens in over 12,000 specimens from both male and female subjects in Germany and the United States. The analytical sensitivity was ≤40 EB/ml for Chlamydia trachomatis (CT) and ≤1 CFU/ml for Neisseria gonorrhoeae (NG). Using clinical specimens, the overall percent agreement with the Cobas(®) 4800 CT/NG Test was >98.5%. Across urogenital specimens, there were 93 discrepant specimens; 76 (93.8%) of 81 CT discrepant specimens were 6800+/4800– and 10 (83.3%) of 12 NG discrepant specimens were 6800+/4800–. Sequencing verified CT results for 45 (61.6%) of 73 samples positive by 6800 and 1 (20%) of 5 positive by 4800. Similarly, 7 (70.0%) of 10 NG samples positive by 6800 and 1 of 2 positive by 4800 were confirmed by sequencing. Among discrepant extragenital specimens (all 6800+/4800–), 7 (50%) of 14 oropharyngeal and 23 (76.7%) of 30 anorectal CT discordant samples were confirmed as CT positive by sequencing; all 8 anorectal and 20 (90.9%) of 22 oropharyngeal NG discordant results were also confirmed as NG positive. In conclusion, Cobas(®) CT/NG for use on the Cobas(®) 6800/8800 Systems provides high-throughput automated solutions for sexually transmitted infection (STI) screening programs. |
format | Online Article Text |
id | pubmed-5632745 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Akadémiai Kiadó |
record_format | MEDLINE/PubMed |
spelling | pubmed-56327452017-10-13 High-Throughput Testing of Urogenital and Extragenital Specimens for Detection of Chlamydia Trachomatis and Neisseria Gonorrhoeae with Cobas(®) CT/NG Marlowe, Elizabeth M. Hardy, David Krevolin, Mark Gohl, Peter Bertram, Alexander Arcenas, Rodney Seiverth, Britta Schneider, Tanja Liesenfeld, Oliver Eur J Microbiol Immunol (Bp) Original Article We compared the analytical and clinical performance of cobas(®) CT/NG for use on the Cobas(®) 6800/8800 Systems with the Cobas(®) 4800 CT/NG Test from urogenital and extragenital specimens in over 12,000 specimens from both male and female subjects in Germany and the United States. The analytical sensitivity was ≤40 EB/ml for Chlamydia trachomatis (CT) and ≤1 CFU/ml for Neisseria gonorrhoeae (NG). Using clinical specimens, the overall percent agreement with the Cobas(®) 4800 CT/NG Test was >98.5%. Across urogenital specimens, there were 93 discrepant specimens; 76 (93.8%) of 81 CT discrepant specimens were 6800+/4800– and 10 (83.3%) of 12 NG discrepant specimens were 6800+/4800–. Sequencing verified CT results for 45 (61.6%) of 73 samples positive by 6800 and 1 (20%) of 5 positive by 4800. Similarly, 7 (70.0%) of 10 NG samples positive by 6800 and 1 of 2 positive by 4800 were confirmed by sequencing. Among discrepant extragenital specimens (all 6800+/4800–), 7 (50%) of 14 oropharyngeal and 23 (76.7%) of 30 anorectal CT discordant samples were confirmed as CT positive by sequencing; all 8 anorectal and 20 (90.9%) of 22 oropharyngeal NG discordant results were also confirmed as NG positive. In conclusion, Cobas(®) CT/NG for use on the Cobas(®) 6800/8800 Systems provides high-throughput automated solutions for sexually transmitted infection (STI) screening programs. Akadémiai Kiadó 2017-09-11 /pmc/articles/PMC5632745/ /pubmed/29034107 http://dx.doi.org/10.1556/1886.2017.00018 Text en © 2017, The Author(s) http://creativecommons.org/licenses/by-nc/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (https://creativecommons.org/licenses/by-nc/4.0/), which permits unrestricted use, distribution, and reproduction in any medium for non-commercial purposes, provided the original author and source are credited, a link to the CC License is provided, and changes – if any – are indicated. |
spellingShingle | Original Article Marlowe, Elizabeth M. Hardy, David Krevolin, Mark Gohl, Peter Bertram, Alexander Arcenas, Rodney Seiverth, Britta Schneider, Tanja Liesenfeld, Oliver High-Throughput Testing of Urogenital and Extragenital Specimens for Detection of Chlamydia Trachomatis and Neisseria Gonorrhoeae with Cobas(®) CT/NG |
title | High-Throughput Testing of Urogenital and Extragenital Specimens for Detection of Chlamydia Trachomatis and Neisseria Gonorrhoeae with Cobas(®) CT/NG |
title_full | High-Throughput Testing of Urogenital and Extragenital Specimens for Detection of Chlamydia Trachomatis and Neisseria Gonorrhoeae with Cobas(®) CT/NG |
title_fullStr | High-Throughput Testing of Urogenital and Extragenital Specimens for Detection of Chlamydia Trachomatis and Neisseria Gonorrhoeae with Cobas(®) CT/NG |
title_full_unstemmed | High-Throughput Testing of Urogenital and Extragenital Specimens for Detection of Chlamydia Trachomatis and Neisseria Gonorrhoeae with Cobas(®) CT/NG |
title_short | High-Throughput Testing of Urogenital and Extragenital Specimens for Detection of Chlamydia Trachomatis and Neisseria Gonorrhoeae with Cobas(®) CT/NG |
title_sort | high-throughput testing of urogenital and extragenital specimens for detection of chlamydia trachomatis and neisseria gonorrhoeae with cobas(®) ct/ng |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5632745/ https://www.ncbi.nlm.nih.gov/pubmed/29034107 http://dx.doi.org/10.1556/1886.2017.00018 |
work_keys_str_mv | AT marloweelizabethm highthroughputtestingofurogenitalandextragenitalspecimensfordetectionofchlamydiatrachomatisandneisseriagonorrhoeaewithcobasctng AT hardydavid highthroughputtestingofurogenitalandextragenitalspecimensfordetectionofchlamydiatrachomatisandneisseriagonorrhoeaewithcobasctng AT krevolinmark highthroughputtestingofurogenitalandextragenitalspecimensfordetectionofchlamydiatrachomatisandneisseriagonorrhoeaewithcobasctng AT gohlpeter highthroughputtestingofurogenitalandextragenitalspecimensfordetectionofchlamydiatrachomatisandneisseriagonorrhoeaewithcobasctng AT bertramalexander highthroughputtestingofurogenitalandextragenitalspecimensfordetectionofchlamydiatrachomatisandneisseriagonorrhoeaewithcobasctng AT arcenasrodney highthroughputtestingofurogenitalandextragenitalspecimensfordetectionofchlamydiatrachomatisandneisseriagonorrhoeaewithcobasctng AT seiverthbritta highthroughputtestingofurogenitalandextragenitalspecimensfordetectionofchlamydiatrachomatisandneisseriagonorrhoeaewithcobasctng AT schneidertanja highthroughputtestingofurogenitalandextragenitalspecimensfordetectionofchlamydiatrachomatisandneisseriagonorrhoeaewithcobasctng AT liesenfeldoliver highthroughputtestingofurogenitalandextragenitalspecimensfordetectionofchlamydiatrachomatisandneisseriagonorrhoeaewithcobasctng |