Bioabsorbable self-retaining PLA/nano-sized β-TCP cervical spine interbody fusion cage in goat models: an in vivo study
STUDY DESIGN: This is an experimental animal study. OBJECTIVE: The objective of this study was to compare an anterior cervical discectomy and interbody fusion of a novel polylactide/nano-sized β-tricalcium phosphate (PLA/nβ-TCP) bioabsorbable self-retaining cervical fusion cage (BCFC) with an autolo...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5633287/ https://www.ncbi.nlm.nih.gov/pubmed/29042769 http://dx.doi.org/10.2147/IJN.S132041 |
_version_ | 1783269863230275584 |
---|---|
author | Cao, Lu Chen, Qian Jiang, Li-Bo Yin, Xiao-Fan Bian, Chong Wang, Hui-Ren Ma, Yi-Qun Li, Xiang-Qian Li, Xi-Lei Dong, Jian |
author_facet | Cao, Lu Chen, Qian Jiang, Li-Bo Yin, Xiao-Fan Bian, Chong Wang, Hui-Ren Ma, Yi-Qun Li, Xiang-Qian Li, Xi-Lei Dong, Jian |
author_sort | Cao, Lu |
collection | PubMed |
description | STUDY DESIGN: This is an experimental animal study. OBJECTIVE: The objective of this study was to compare an anterior cervical discectomy and interbody fusion of a novel polylactide/nano-sized β-tricalcium phosphate (PLA/nβ-TCP) bioabsorbable self-retaining cervical fusion cage (BCFC) with an autologous bone graft and polyetheretherketone (PEEK) cages. BACKGROUND: Although PLA cervical cages have potential advantages compared with traditional materials, they are not currently routinely used in spine surgery because of undesirable effects such as the lack of osteoconductivity and osteolysis around the implant. This study involved the manufacturing of a bioabsorbable cage from PLA/nβ-TCP that was then used as a device for anterior cervical discectomy and fusion (ACDF) on a goat cervical spine fusion model. MATERIALS AND METHODS: Eighteen goats underwent C3/C4 discectomy and were randomly divided into three groups based on the following methods: Group A (n=6), an autologous bone graft; Group B (n=6), PEEK cage filled with an autologous graft; and Group C (n=6), BCFC filled with an autologous iliac bone. Radiography was performed preoperatively and postoperatively and at 1, 4, 8, and 12 weeks after the operation. Disc space height (DSH) was measured at the same time. After 12 weeks, the fused segments were harvested and evaluated with functional radiographic views, biomechanical testing, and histological analyses. RESULTS: Over a 12-week period, the BCFC and PEEK cage groups exhibited significantly higher DSH values than the bone graft group. Additionally, the BCFC group yielded a significantly lower range of motion in axial rotation than both the autologous bone graft and PEEK cage groups. A histologic evaluation revealed an increased intervertebral bone volume/total volume ratio and better interbody fusion in the BCFC group than in the other groups. CONCLUSION: The BCFC device exhibited better results than the autologous bone graft and PEEK cages in single-level ACDF models in vivo. This device may be a potential alternative to the current PEEK cages. |
format | Online Article Text |
id | pubmed-5633287 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Dove Medical Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-56332872017-10-17 Bioabsorbable self-retaining PLA/nano-sized β-TCP cervical spine interbody fusion cage in goat models: an in vivo study Cao, Lu Chen, Qian Jiang, Li-Bo Yin, Xiao-Fan Bian, Chong Wang, Hui-Ren Ma, Yi-Qun Li, Xiang-Qian Li, Xi-Lei Dong, Jian Int J Nanomedicine Original Research STUDY DESIGN: This is an experimental animal study. OBJECTIVE: The objective of this study was to compare an anterior cervical discectomy and interbody fusion of a novel polylactide/nano-sized β-tricalcium phosphate (PLA/nβ-TCP) bioabsorbable self-retaining cervical fusion cage (BCFC) with an autologous bone graft and polyetheretherketone (PEEK) cages. BACKGROUND: Although PLA cervical cages have potential advantages compared with traditional materials, they are not currently routinely used in spine surgery because of undesirable effects such as the lack of osteoconductivity and osteolysis around the implant. This study involved the manufacturing of a bioabsorbable cage from PLA/nβ-TCP that was then used as a device for anterior cervical discectomy and fusion (ACDF) on a goat cervical spine fusion model. MATERIALS AND METHODS: Eighteen goats underwent C3/C4 discectomy and were randomly divided into three groups based on the following methods: Group A (n=6), an autologous bone graft; Group B (n=6), PEEK cage filled with an autologous graft; and Group C (n=6), BCFC filled with an autologous iliac bone. Radiography was performed preoperatively and postoperatively and at 1, 4, 8, and 12 weeks after the operation. Disc space height (DSH) was measured at the same time. After 12 weeks, the fused segments were harvested and evaluated with functional radiographic views, biomechanical testing, and histological analyses. RESULTS: Over a 12-week period, the BCFC and PEEK cage groups exhibited significantly higher DSH values than the bone graft group. Additionally, the BCFC group yielded a significantly lower range of motion in axial rotation than both the autologous bone graft and PEEK cage groups. A histologic evaluation revealed an increased intervertebral bone volume/total volume ratio and better interbody fusion in the BCFC group than in the other groups. CONCLUSION: The BCFC device exhibited better results than the autologous bone graft and PEEK cages in single-level ACDF models in vivo. This device may be a potential alternative to the current PEEK cages. Dove Medical Press 2017-10-03 /pmc/articles/PMC5633287/ /pubmed/29042769 http://dx.doi.org/10.2147/IJN.S132041 Text en © 2017 Cao et al. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. |
spellingShingle | Original Research Cao, Lu Chen, Qian Jiang, Li-Bo Yin, Xiao-Fan Bian, Chong Wang, Hui-Ren Ma, Yi-Qun Li, Xiang-Qian Li, Xi-Lei Dong, Jian Bioabsorbable self-retaining PLA/nano-sized β-TCP cervical spine interbody fusion cage in goat models: an in vivo study |
title | Bioabsorbable self-retaining PLA/nano-sized β-TCP cervical spine interbody fusion cage in goat models: an in vivo study |
title_full | Bioabsorbable self-retaining PLA/nano-sized β-TCP cervical spine interbody fusion cage in goat models: an in vivo study |
title_fullStr | Bioabsorbable self-retaining PLA/nano-sized β-TCP cervical spine interbody fusion cage in goat models: an in vivo study |
title_full_unstemmed | Bioabsorbable self-retaining PLA/nano-sized β-TCP cervical spine interbody fusion cage in goat models: an in vivo study |
title_short | Bioabsorbable self-retaining PLA/nano-sized β-TCP cervical spine interbody fusion cage in goat models: an in vivo study |
title_sort | bioabsorbable self-retaining pla/nano-sized β-tcp cervical spine interbody fusion cage in goat models: an in vivo study |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5633287/ https://www.ncbi.nlm.nih.gov/pubmed/29042769 http://dx.doi.org/10.2147/IJN.S132041 |
work_keys_str_mv | AT caolu bioabsorbableselfretainingplananosizedbtcpcervicalspineinterbodyfusioncageingoatmodelsaninvivostudy AT chenqian bioabsorbableselfretainingplananosizedbtcpcervicalspineinterbodyfusioncageingoatmodelsaninvivostudy AT jianglibo bioabsorbableselfretainingplananosizedbtcpcervicalspineinterbodyfusioncageingoatmodelsaninvivostudy AT yinxiaofan bioabsorbableselfretainingplananosizedbtcpcervicalspineinterbodyfusioncageingoatmodelsaninvivostudy AT bianchong bioabsorbableselfretainingplananosizedbtcpcervicalspineinterbodyfusioncageingoatmodelsaninvivostudy AT wanghuiren bioabsorbableselfretainingplananosizedbtcpcervicalspineinterbodyfusioncageingoatmodelsaninvivostudy AT mayiqun bioabsorbableselfretainingplananosizedbtcpcervicalspineinterbodyfusioncageingoatmodelsaninvivostudy AT lixiangqian bioabsorbableselfretainingplananosizedbtcpcervicalspineinterbodyfusioncageingoatmodelsaninvivostudy AT lixilei bioabsorbableselfretainingplananosizedbtcpcervicalspineinterbodyfusioncageingoatmodelsaninvivostudy AT dongjian bioabsorbableselfretainingplananosizedbtcpcervicalspineinterbodyfusioncageingoatmodelsaninvivostudy |