Cargando…
Characterization of lens based photoacoustic imaging system()
Some of the challenges in translating photoacoustic (PA) imaging to clinical applications includes limited view of the target tissue, low signal to noise ratio and the high cost of developing real-time systems. Acoustic lens based PA imaging systems, also known as PA cameras are a potential alternat...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5633851/ https://www.ncbi.nlm.nih.gov/pubmed/29034167 http://dx.doi.org/10.1016/j.pacs.2017.09.003 |
_version_ | 1783269966794981376 |
---|---|
author | Francis, Kalloor Joseph Chinni, Bhargava Channappayya, Sumohana S. Pachamuthu, Rajalakshmi Dogra, Vikram S. Rao, Navalgund |
author_facet | Francis, Kalloor Joseph Chinni, Bhargava Channappayya, Sumohana S. Pachamuthu, Rajalakshmi Dogra, Vikram S. Rao, Navalgund |
author_sort | Francis, Kalloor Joseph |
collection | PubMed |
description | Some of the challenges in translating photoacoustic (PA) imaging to clinical applications includes limited view of the target tissue, low signal to noise ratio and the high cost of developing real-time systems. Acoustic lens based PA imaging systems, also known as PA cameras are a potential alternative to conventional imaging systems in these scenarios. The 3D focusing action of lens enables real-time C-scan imaging with a 2D transducer array. In this paper, we model the underlying physics in a PA camera in the mathematical framework of an imaging system and derive a closed form expression for the point spread function (PSF). Experimental verification follows including the details on how to design and fabricate the lens inexpensively. The system PSF is evaluated over a 3D volume that can be imaged by this PA camera. Its utility is demonstrated by imaging phantom and an ex vivo human prostate tissue sample. |
format | Online Article Text |
id | pubmed-5633851 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-56338512017-10-13 Characterization of lens based photoacoustic imaging system() Francis, Kalloor Joseph Chinni, Bhargava Channappayya, Sumohana S. Pachamuthu, Rajalakshmi Dogra, Vikram S. Rao, Navalgund Photoacoustics Research Article Some of the challenges in translating photoacoustic (PA) imaging to clinical applications includes limited view of the target tissue, low signal to noise ratio and the high cost of developing real-time systems. Acoustic lens based PA imaging systems, also known as PA cameras are a potential alternative to conventional imaging systems in these scenarios. The 3D focusing action of lens enables real-time C-scan imaging with a 2D transducer array. In this paper, we model the underlying physics in a PA camera in the mathematical framework of an imaging system and derive a closed form expression for the point spread function (PSF). Experimental verification follows including the details on how to design and fabricate the lens inexpensively. The system PSF is evaluated over a 3D volume that can be imaged by this PA camera. Its utility is demonstrated by imaging phantom and an ex vivo human prostate tissue sample. Elsevier 2017-09-23 /pmc/articles/PMC5633851/ /pubmed/29034167 http://dx.doi.org/10.1016/j.pacs.2017.09.003 Text en © 2017 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Research Article Francis, Kalloor Joseph Chinni, Bhargava Channappayya, Sumohana S. Pachamuthu, Rajalakshmi Dogra, Vikram S. Rao, Navalgund Characterization of lens based photoacoustic imaging system() |
title | Characterization of lens based photoacoustic imaging system() |
title_full | Characterization of lens based photoacoustic imaging system() |
title_fullStr | Characterization of lens based photoacoustic imaging system() |
title_full_unstemmed | Characterization of lens based photoacoustic imaging system() |
title_short | Characterization of lens based photoacoustic imaging system() |
title_sort | characterization of lens based photoacoustic imaging system() |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5633851/ https://www.ncbi.nlm.nih.gov/pubmed/29034167 http://dx.doi.org/10.1016/j.pacs.2017.09.003 |
work_keys_str_mv | AT franciskalloorjoseph characterizationoflensbasedphotoacousticimagingsystem AT chinnibhargava characterizationoflensbasedphotoacousticimagingsystem AT channappayyasumohanas characterizationoflensbasedphotoacousticimagingsystem AT pachamuthurajalakshmi characterizationoflensbasedphotoacousticimagingsystem AT dogravikrams characterizationoflensbasedphotoacousticimagingsystem AT raonavalgund characterizationoflensbasedphotoacousticimagingsystem |