The Reversed Less Invasive Stabilisation System-Distal Femur Technique: Application in an Adult Patient with Osteogenesis Imperfecta Sustaining a Femoral Fracture

INTRODUCTION: The aim of this study was to report the surgical management and to discuss the options for fracture fixation in an adult patient with osteogenesis imperfecta (OI) who sustained a trochanteric femoral fracture after a simple fall from standing position. CASE REPORT: As a result of multi...

Descripción completa

Detalles Bibliográficos
Autores principales: Hanke, Markus S, Keel, Marius Johann, Todorski, Inga A, Bastian, Johannes Dominik
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Indian Orthopaedic Research Group 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5635193/
https://www.ncbi.nlm.nih.gov/pubmed/29051885
http://dx.doi.org/10.13107/jocr.2250-0685.812
_version_ 1783270238498848768
author Hanke, Markus S
Keel, Marius Johann
Todorski, Inga A
Bastian, Johannes Dominik
author_facet Hanke, Markus S
Keel, Marius Johann
Todorski, Inga A
Bastian, Johannes Dominik
author_sort Hanke, Markus S
collection PubMed
description INTRODUCTION: The aim of this study was to report the surgical management and to discuss the options for fracture fixation in an adult patient with osteogenesis imperfecta (OI) who sustained a trochanteric femoral fracture after a simple fall from standing position. CASE REPORT: As a result of multiple fractures during childhood, this adult patient with OI presented with a short stature. The radiographs revealed a displaced, intertrochanteric fracture with subtrochanteric extension of the left femur. The intramedullary canal was narrow, the femur presented with a severe bowing deformity, and the bone quality was poor. The implant of choice was plating using the reversed less invasive stabilisation system-distal femur (LISS-DF) technique. This technique was introduced for the management of subtrochanteric fractures in the elderly with poor bone stock. In addition, a locking plate attached to the LISS-DF allowed for additional screw placement at the apex of the curvature of the femur although the plate was not in line with the femur at this site. Cerclages were used for metaphyseal reduction and fixation. 4-month postoperatively, the patient was ambulatory without any assistance with full weight bearing. At the latest follow-up 1-year postoperatively, the patient was still free of complaints and at her preinjury activity level. CONCLUSION: The presented technique was successful as a salvage procedure in a rare case of adult OI presenting with a femoral fracture with characteristics influencing the decision-making in treatment options.
format Online
Article
Text
id pubmed-5635193
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Indian Orthopaedic Research Group
record_format MEDLINE/PubMed
spelling pubmed-56351932017-10-19 The Reversed Less Invasive Stabilisation System-Distal Femur Technique: Application in an Adult Patient with Osteogenesis Imperfecta Sustaining a Femoral Fracture Hanke, Markus S Keel, Marius Johann Todorski, Inga A Bastian, Johannes Dominik J Orthop Case Rep Case Report INTRODUCTION: The aim of this study was to report the surgical management and to discuss the options for fracture fixation in an adult patient with osteogenesis imperfecta (OI) who sustained a trochanteric femoral fracture after a simple fall from standing position. CASE REPORT: As a result of multiple fractures during childhood, this adult patient with OI presented with a short stature. The radiographs revealed a displaced, intertrochanteric fracture with subtrochanteric extension of the left femur. The intramedullary canal was narrow, the femur presented with a severe bowing deformity, and the bone quality was poor. The implant of choice was plating using the reversed less invasive stabilisation system-distal femur (LISS-DF) technique. This technique was introduced for the management of subtrochanteric fractures in the elderly with poor bone stock. In addition, a locking plate attached to the LISS-DF allowed for additional screw placement at the apex of the curvature of the femur although the plate was not in line with the femur at this site. Cerclages were used for metaphyseal reduction and fixation. 4-month postoperatively, the patient was ambulatory without any assistance with full weight bearing. At the latest follow-up 1-year postoperatively, the patient was still free of complaints and at her preinjury activity level. CONCLUSION: The presented technique was successful as a salvage procedure in a rare case of adult OI presenting with a femoral fracture with characteristics influencing the decision-making in treatment options. Indian Orthopaedic Research Group 2017 /pmc/articles/PMC5635193/ /pubmed/29051885 http://dx.doi.org/10.13107/jocr.2250-0685.812 Text en Copyright: © Indian Orthopaedic Research Group http://creativecommons.org/licenses/by-nc/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Hanke, Markus S
Keel, Marius Johann
Todorski, Inga A
Bastian, Johannes Dominik
The Reversed Less Invasive Stabilisation System-Distal Femur Technique: Application in an Adult Patient with Osteogenesis Imperfecta Sustaining a Femoral Fracture
title The Reversed Less Invasive Stabilisation System-Distal Femur Technique: Application in an Adult Patient with Osteogenesis Imperfecta Sustaining a Femoral Fracture
title_full The Reversed Less Invasive Stabilisation System-Distal Femur Technique: Application in an Adult Patient with Osteogenesis Imperfecta Sustaining a Femoral Fracture
title_fullStr The Reversed Less Invasive Stabilisation System-Distal Femur Technique: Application in an Adult Patient with Osteogenesis Imperfecta Sustaining a Femoral Fracture
title_full_unstemmed The Reversed Less Invasive Stabilisation System-Distal Femur Technique: Application in an Adult Patient with Osteogenesis Imperfecta Sustaining a Femoral Fracture
title_short The Reversed Less Invasive Stabilisation System-Distal Femur Technique: Application in an Adult Patient with Osteogenesis Imperfecta Sustaining a Femoral Fracture
title_sort reversed less invasive stabilisation system-distal femur technique: application in an adult patient with osteogenesis imperfecta sustaining a femoral fracture
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5635193/
https://www.ncbi.nlm.nih.gov/pubmed/29051885
http://dx.doi.org/10.13107/jocr.2250-0685.812
work_keys_str_mv AT hankemarkuss thereversedlessinvasivestabilisationsystemdistalfemurtechniqueapplicationinanadultpatientwithosteogenesisimperfectasustainingafemoralfracture
AT keelmariusjohann thereversedlessinvasivestabilisationsystemdistalfemurtechniqueapplicationinanadultpatientwithosteogenesisimperfectasustainingafemoralfracture
AT todorskiingaa thereversedlessinvasivestabilisationsystemdistalfemurtechniqueapplicationinanadultpatientwithosteogenesisimperfectasustainingafemoralfracture
AT bastianjohannesdominik thereversedlessinvasivestabilisationsystemdistalfemurtechniqueapplicationinanadultpatientwithosteogenesisimperfectasustainingafemoralfracture
AT hankemarkuss reversedlessinvasivestabilisationsystemdistalfemurtechniqueapplicationinanadultpatientwithosteogenesisimperfectasustainingafemoralfracture
AT keelmariusjohann reversedlessinvasivestabilisationsystemdistalfemurtechniqueapplicationinanadultpatientwithosteogenesisimperfectasustainingafemoralfracture
AT todorskiingaa reversedlessinvasivestabilisationsystemdistalfemurtechniqueapplicationinanadultpatientwithosteogenesisimperfectasustainingafemoralfracture
AT bastianjohannesdominik reversedlessinvasivestabilisationsystemdistalfemurtechniqueapplicationinanadultpatientwithosteogenesisimperfectasustainingafemoralfracture