Cargando…

Treatment of thoracic or lumbar burst fractures with Balloon Assisted Endplate Reduction using Tricalcium Phosphate cement: histological and radiological evaluation

BACKGROUND: Short-segment pedicle-screw instrumentation is frequently used to stabilize thoracolumbar burst fractures. A recognized disadvantage of this procedure is recurrent kyphosis from intervertebral disc creep into the fractured central endplate. Balloon Assisted Endplate Reduction (BAER) usin...

Descripción completa

Detalles Bibliográficos
Autores principales: Kitzen, Joep, Schotanus, Martijn G. M., Plasschaert, Herbert S. W., Hulsmans, Frans-Jan H., Tilman, Pieter B. J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5635504/
https://www.ncbi.nlm.nih.gov/pubmed/29017495
http://dx.doi.org/10.1186/s12891-017-1770-3
_version_ 1783270300021948416
author Kitzen, Joep
Schotanus, Martijn G. M.
Plasschaert, Herbert S. W.
Hulsmans, Frans-Jan H.
Tilman, Pieter B. J.
author_facet Kitzen, Joep
Schotanus, Martijn G. M.
Plasschaert, Herbert S. W.
Hulsmans, Frans-Jan H.
Tilman, Pieter B. J.
author_sort Kitzen, Joep
collection PubMed
description BACKGROUND: Short-segment pedicle-screw instrumentation is frequently used to stabilize thoracolumbar burst fractures. A recognized disadvantage of this procedure is recurrent kyphosis from intervertebral disc creep into the fractured central endplate. Balloon Assisted Endplate Reduction (BAER) using Tricalcium Phosphate bone cement (TCP) enables elevation of the centrally depressed endplate. Our objective was to evaluate the bone-tissue response to TCP and to analyse whether BAER using TCP can prevent recurrent kyphosis after removal of the instrumentation. METHODS: Fourteen patients with traumatic thoracolumbar burst fractures were operated with BAER using TCP in combination with short-segment instrumentation. Nine months after surgery, instrumentation was removed and transpedicular biopsies were taken for histological and histochemical analysis. Roentgenograms pre- and postoperatively and at latest follow-up after removal of the instrumentation were evaluated. RESULTS: Average follow-up was 2.6 years. Analysis of the biopsies showed a variable degree of bone remodelling with incorporation of TCP into newly formed bone matrix. No extensive foreign body reactions, inflammation, granulomatous responses or tissue necrosis were observed. Wedge-angle, kyphosis-angle and both the anterior-posterior and central-posterior vertebral body height ratios improved significant postoperatively (p < 0.001). After removal of the instrumentation no significant differences in wedge-angle or height ratios were seen (p = 0.12). The kyphosis-angle increased four degrees (p = 0.01). CONCLUSION: TCP showed good histological osseointegration with no adverse events. TCP can therefore be safely used and could be beneficial in treatment of thoracolumbar burst fractures. BAER with TCP in combination with short-segment instrumentation might reduce recurrence of deformity even after removal of the instrumentation in comparison to short-segment instrumentation alone. TRIAL REGISTRATION: This study is registered at the at the Dutch Trial Registry (NTR3498).
format Online
Article
Text
id pubmed-5635504
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-56355042017-10-18 Treatment of thoracic or lumbar burst fractures with Balloon Assisted Endplate Reduction using Tricalcium Phosphate cement: histological and radiological evaluation Kitzen, Joep Schotanus, Martijn G. M. Plasschaert, Herbert S. W. Hulsmans, Frans-Jan H. Tilman, Pieter B. J. BMC Musculoskelet Disord Research Article BACKGROUND: Short-segment pedicle-screw instrumentation is frequently used to stabilize thoracolumbar burst fractures. A recognized disadvantage of this procedure is recurrent kyphosis from intervertebral disc creep into the fractured central endplate. Balloon Assisted Endplate Reduction (BAER) using Tricalcium Phosphate bone cement (TCP) enables elevation of the centrally depressed endplate. Our objective was to evaluate the bone-tissue response to TCP and to analyse whether BAER using TCP can prevent recurrent kyphosis after removal of the instrumentation. METHODS: Fourteen patients with traumatic thoracolumbar burst fractures were operated with BAER using TCP in combination with short-segment instrumentation. Nine months after surgery, instrumentation was removed and transpedicular biopsies were taken for histological and histochemical analysis. Roentgenograms pre- and postoperatively and at latest follow-up after removal of the instrumentation were evaluated. RESULTS: Average follow-up was 2.6 years. Analysis of the biopsies showed a variable degree of bone remodelling with incorporation of TCP into newly formed bone matrix. No extensive foreign body reactions, inflammation, granulomatous responses or tissue necrosis were observed. Wedge-angle, kyphosis-angle and both the anterior-posterior and central-posterior vertebral body height ratios improved significant postoperatively (p < 0.001). After removal of the instrumentation no significant differences in wedge-angle or height ratios were seen (p = 0.12). The kyphosis-angle increased four degrees (p = 0.01). CONCLUSION: TCP showed good histological osseointegration with no adverse events. TCP can therefore be safely used and could be beneficial in treatment of thoracolumbar burst fractures. BAER with TCP in combination with short-segment instrumentation might reduce recurrence of deformity even after removal of the instrumentation in comparison to short-segment instrumentation alone. TRIAL REGISTRATION: This study is registered at the at the Dutch Trial Registry (NTR3498). BioMed Central 2017-10-10 /pmc/articles/PMC5635504/ /pubmed/29017495 http://dx.doi.org/10.1186/s12891-017-1770-3 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Kitzen, Joep
Schotanus, Martijn G. M.
Plasschaert, Herbert S. W.
Hulsmans, Frans-Jan H.
Tilman, Pieter B. J.
Treatment of thoracic or lumbar burst fractures with Balloon Assisted Endplate Reduction using Tricalcium Phosphate cement: histological and radiological evaluation
title Treatment of thoracic or lumbar burst fractures with Balloon Assisted Endplate Reduction using Tricalcium Phosphate cement: histological and radiological evaluation
title_full Treatment of thoracic or lumbar burst fractures with Balloon Assisted Endplate Reduction using Tricalcium Phosphate cement: histological and radiological evaluation
title_fullStr Treatment of thoracic or lumbar burst fractures with Balloon Assisted Endplate Reduction using Tricalcium Phosphate cement: histological and radiological evaluation
title_full_unstemmed Treatment of thoracic or lumbar burst fractures with Balloon Assisted Endplate Reduction using Tricalcium Phosphate cement: histological and radiological evaluation
title_short Treatment of thoracic or lumbar burst fractures with Balloon Assisted Endplate Reduction using Tricalcium Phosphate cement: histological and radiological evaluation
title_sort treatment of thoracic or lumbar burst fractures with balloon assisted endplate reduction using tricalcium phosphate cement: histological and radiological evaluation
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5635504/
https://www.ncbi.nlm.nih.gov/pubmed/29017495
http://dx.doi.org/10.1186/s12891-017-1770-3
work_keys_str_mv AT kitzenjoep treatmentofthoracicorlumbarburstfractureswithballoonassistedendplatereductionusingtricalciumphosphatecementhistologicalandradiologicalevaluation
AT schotanusmartijngm treatmentofthoracicorlumbarburstfractureswithballoonassistedendplatereductionusingtricalciumphosphatecementhistologicalandradiologicalevaluation
AT plasschaertherbertsw treatmentofthoracicorlumbarburstfractureswithballoonassistedendplatereductionusingtricalciumphosphatecementhistologicalandradiologicalevaluation
AT hulsmansfransjanh treatmentofthoracicorlumbarburstfractureswithballoonassistedendplatereductionusingtricalciumphosphatecementhistologicalandradiologicalevaluation
AT tilmanpieterbj treatmentofthoracicorlumbarburstfractureswithballoonassistedendplatereductionusingtricalciumphosphatecementhistologicalandradiologicalevaluation