Cargando…

Comparison of the T2-star Values of Placentas Obtained from Pre-eclamptic Patients with Those of a Control Group: an Ex-vivo Magnetic Resonance Imaging Study

BACKGROUND: Endotel dysfunction, vasoconstriction, and oxidative stress are described in the pathophysiology of pre-eclampsia, but its aetiology has not been revealed clearly. AIMS: To examine whether there is a difference between the placentas of pre-eclamptic pregnant women and those of a control...

Descripción completa

Detalles Bibliográficos
Autores principales: Yurttutan, Nursel, Bakacak, Murat, Kızıldağ, Betül
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Galenos Publishing 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5635627/
https://www.ncbi.nlm.nih.gov/pubmed/28552841
http://dx.doi.org/10.4274/balkanmedj.2016.1472
_version_ 1783270326848716800
author Yurttutan, Nursel
Bakacak, Murat
Kızıldağ, Betül
author_facet Yurttutan, Nursel
Bakacak, Murat
Kızıldağ, Betül
author_sort Yurttutan, Nursel
collection PubMed
description BACKGROUND: Endotel dysfunction, vasoconstriction, and oxidative stress are described in the pathophysiology of pre-eclampsia, but its aetiology has not been revealed clearly. AIMS: To examine whether there is a difference between the placentas of pre-eclamptic pregnant women and those of a control group in terms of their T2 star values. STUDY DESIGN: Case-control study. METHODS: Twenty patients diagnosed with pre-eclampsia and 22 healthy controls were included in this study. The placentas obtained after births performed via Caesarean section were taken into the magnetic resonance imaging area in plastic bags within the first postnatal hour, and imaging was performed via modified DIXON-Quant sequence. Average values were obtained by performing T2 star measurements from four localisations on the placentas. RESULTS: T2 star values measured in the placentas of the control group were found to be significantly lower than those in the pre-eclampsia group (p<0.01). While the mean T2 star value in the pre-eclamptic group was found to be 37.48 ms (standard deviation ± 11.3), this value was 28.74 (standard deviation ± 8.08) in the control group. The cut-off value for the T2 star value, maximising the accuracy of diagnosis, was 28.59 ms (area under curve: 0.741; 95% confidence interval: 0.592-0.890); sensitivity and specificity were 70% and 63.6%, respectively. CONCLUSION: This study, the T2 star value, which is an indicator of iron amount, was found to be significantly lower in the control group than in the pre-eclampsia group. This may be related to the reduction in blood flow to the placenta due to endothelial dysfunction and vasoconstriction, which are important in pre-eclampsia pathophysiology.
format Online
Article
Text
id pubmed-5635627
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Galenos Publishing
record_format MEDLINE/PubMed
spelling pubmed-56356272017-10-18 Comparison of the T2-star Values of Placentas Obtained from Pre-eclamptic Patients with Those of a Control Group: an Ex-vivo Magnetic Resonance Imaging Study Yurttutan, Nursel Bakacak, Murat Kızıldağ, Betül Balkan Med J Original Article BACKGROUND: Endotel dysfunction, vasoconstriction, and oxidative stress are described in the pathophysiology of pre-eclampsia, but its aetiology has not been revealed clearly. AIMS: To examine whether there is a difference between the placentas of pre-eclamptic pregnant women and those of a control group in terms of their T2 star values. STUDY DESIGN: Case-control study. METHODS: Twenty patients diagnosed with pre-eclampsia and 22 healthy controls were included in this study. The placentas obtained after births performed via Caesarean section were taken into the magnetic resonance imaging area in plastic bags within the first postnatal hour, and imaging was performed via modified DIXON-Quant sequence. Average values were obtained by performing T2 star measurements from four localisations on the placentas. RESULTS: T2 star values measured in the placentas of the control group were found to be significantly lower than those in the pre-eclampsia group (p<0.01). While the mean T2 star value in the pre-eclamptic group was found to be 37.48 ms (standard deviation ± 11.3), this value was 28.74 (standard deviation ± 8.08) in the control group. The cut-off value for the T2 star value, maximising the accuracy of diagnosis, was 28.59 ms (area under curve: 0.741; 95% confidence interval: 0.592-0.890); sensitivity and specificity were 70% and 63.6%, respectively. CONCLUSION: This study, the T2 star value, which is an indicator of iron amount, was found to be significantly lower in the control group than in the pre-eclampsia group. This may be related to the reduction in blood flow to the placenta due to endothelial dysfunction and vasoconstriction, which are important in pre-eclampsia pathophysiology. Galenos Publishing 2017-09 2017-09-29 /pmc/articles/PMC5635627/ /pubmed/28552841 http://dx.doi.org/10.4274/balkanmedj.2016.1472 Text en © Copyright 2017, Trakya University Faculty of Medicine http://creativecommons.org/licenses/by/2.5/ Balkan Medical Journal
spellingShingle Original Article
Yurttutan, Nursel
Bakacak, Murat
Kızıldağ, Betül
Comparison of the T2-star Values of Placentas Obtained from Pre-eclamptic Patients with Those of a Control Group: an Ex-vivo Magnetic Resonance Imaging Study
title Comparison of the T2-star Values of Placentas Obtained from Pre-eclamptic Patients with Those of a Control Group: an Ex-vivo Magnetic Resonance Imaging Study
title_full Comparison of the T2-star Values of Placentas Obtained from Pre-eclamptic Patients with Those of a Control Group: an Ex-vivo Magnetic Resonance Imaging Study
title_fullStr Comparison of the T2-star Values of Placentas Obtained from Pre-eclamptic Patients with Those of a Control Group: an Ex-vivo Magnetic Resonance Imaging Study
title_full_unstemmed Comparison of the T2-star Values of Placentas Obtained from Pre-eclamptic Patients with Those of a Control Group: an Ex-vivo Magnetic Resonance Imaging Study
title_short Comparison of the T2-star Values of Placentas Obtained from Pre-eclamptic Patients with Those of a Control Group: an Ex-vivo Magnetic Resonance Imaging Study
title_sort comparison of the t2-star values of placentas obtained from pre-eclamptic patients with those of a control group: an ex-vivo magnetic resonance imaging study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5635627/
https://www.ncbi.nlm.nih.gov/pubmed/28552841
http://dx.doi.org/10.4274/balkanmedj.2016.1472
work_keys_str_mv AT yurttutannursel comparisonofthet2starvaluesofplacentasobtainedfrompreeclampticpatientswiththoseofacontrolgroupanexvivomagneticresonanceimagingstudy
AT bakacakmurat comparisonofthet2starvaluesofplacentasobtainedfrompreeclampticpatientswiththoseofacontrolgroupanexvivomagneticresonanceimagingstudy
AT kızıldagbetul comparisonofthet2starvaluesofplacentasobtainedfrompreeclampticpatientswiththoseofacontrolgroupanexvivomagneticresonanceimagingstudy