BACKGROUND: Proximal femoral fracture rates are increasing due to osteoporosis and traffic accidents. Proximal femoral nails are routinely used in the treatment of these fractures in the proximal femur. AIMS: To compare various combinations and to determine the ideal proximal lag screw position in p...

Descripción completa

Detalles Bibliográficos
Autores principales: Konya, Mehmet Nuri, Verim, Özgür
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Galenos Publishing 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5635629/
https://www.ncbi.nlm.nih.gov/pubmed/28443571
http://dx.doi.org/10.4274/balkanmedj.2016.0732
_version_ 1783270327370907648
author Konya, Mehmet Nuri
Verim, Özgür
author_facet Konya, Mehmet Nuri
Verim, Özgür
author_sort Konya, Mehmet Nuri
collection PubMed
description BACKGROUND: Proximal femoral fracture rates are increasing due to osteoporosis and traffic accidents. Proximal femoral nails are routinely used in the treatment of these fractures in the proximal femur. AIMS: To compare various combinations and to determine the ideal proximal lag screw position in pertrochanteric fractures (Arbeitsgemeinschaft für Osteosynthesefragen classification 31-A1) of the femur by using optimized finite element analysis. STUDY DESIGN: Biomechanical study. METHODS: Computed tomography images of patients’ right femurs were processed with Mimics. Afterwards a solid femur model was created with SolidWorks 2015 and transferred to ANSYS Workbench 16.0 for response surface optimization analysis which was carried out according to anterior-posterior (-10°<anterior-posterior<10°), inferior-superior (-6°<inferior-superior<7°) and tip-apex distance (10 mm<tip-apex distance<30 mm) proximal lag screw positions in the fracture region. The optimum position of the proximal lag screw was determined based on the von Mises stress values occurring on the fracture line. Initial analysis of the system was realized under the surgeon’s normal positioning conditions (anterior-posterior, inferior-superior=0°; tip-apex distance=12 mm). RESULTS: The maximum and minimum (compression) von Mises stresses were found to be 438 MPa and 0.003 MPa, respectively, and risky stresses for the system occurred in the regions where the proximal lag screw passes through the proximal femoral nail hole, the small diameter portion of stem joints with a large diameter and lag screw mounts to the stem. The most suitable position of the proximal lag screw was found at the middle position of the tip-apex distance (20 mm) and femoral neck (anterior-posterior, inferior-superior=0°), according to von Mises compression stress values occurring on the fracture line. CONCLUSION: In our study, we couldn’t find any correlation between proximal lag screw movement and tip-apex distance on stresses of the fracture surfaces, but the proximal lag screw position in the inferior (inferior-superior<0)-superior (inferior-superior>0) and posterior-anterior directions of the femur neck significantly increased these stresses. The most suitable position of the proximal lag screw was confirmed as the middle of the femoral neck by using optimized finite element analysis.
format Online
Article
Text
id pubmed-5635629
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Galenos Publishing
record_format MEDLINE/PubMed
spelling pubmed-56356292017-10-18 Numerical Optimization of the Position in Femoral Head of Proximal Locking Screws of Proximal Femoral Nail System; Biomechanical Study Konya, Mehmet Nuri Verim, Özgür Balkan Med J Original Article BACKGROUND: Proximal femoral fracture rates are increasing due to osteoporosis and traffic accidents. Proximal femoral nails are routinely used in the treatment of these fractures in the proximal femur. AIMS: To compare various combinations and to determine the ideal proximal lag screw position in pertrochanteric fractures (Arbeitsgemeinschaft für Osteosynthesefragen classification 31-A1) of the femur by using optimized finite element analysis. STUDY DESIGN: Biomechanical study. METHODS: Computed tomography images of patients’ right femurs were processed with Mimics. Afterwards a solid femur model was created with SolidWorks 2015 and transferred to ANSYS Workbench 16.0 for response surface optimization analysis which was carried out according to anterior-posterior (-10°<anterior-posterior<10°), inferior-superior (-6°<inferior-superior<7°) and tip-apex distance (10 mm<tip-apex distance<30 mm) proximal lag screw positions in the fracture region. The optimum position of the proximal lag screw was determined based on the von Mises stress values occurring on the fracture line. Initial analysis of the system was realized under the surgeon’s normal positioning conditions (anterior-posterior, inferior-superior=0°; tip-apex distance=12 mm). RESULTS: The maximum and minimum (compression) von Mises stresses were found to be 438 MPa and 0.003 MPa, respectively, and risky stresses for the system occurred in the regions where the proximal lag screw passes through the proximal femoral nail hole, the small diameter portion of stem joints with a large diameter and lag screw mounts to the stem. The most suitable position of the proximal lag screw was found at the middle position of the tip-apex distance (20 mm) and femoral neck (anterior-posterior, inferior-superior=0°), according to von Mises compression stress values occurring on the fracture line. CONCLUSION: In our study, we couldn’t find any correlation between proximal lag screw movement and tip-apex distance on stresses of the fracture surfaces, but the proximal lag screw position in the inferior (inferior-superior<0)-superior (inferior-superior>0) and posterior-anterior directions of the femur neck significantly increased these stresses. The most suitable position of the proximal lag screw was confirmed as the middle of the femoral neck by using optimized finite element analysis. Galenos Publishing 2017-09 2017-09-29 /pmc/articles/PMC5635629/ /pubmed/28443571 http://dx.doi.org/10.4274/balkanmedj.2016.0732 Text en © Copyright 2017, Trakya University Faculty of Medicine http://creativecommons.org/licenses/by/2.5/ Balkan Medical Journal
spellingShingle Original Article
Konya, Mehmet Nuri
Verim, Özgür
Numerical Optimization of the Position in Femoral Head of Proximal Locking Screws of Proximal Femoral Nail System; Biomechanical Study
title Numerical Optimization of the Position in Femoral Head of Proximal Locking Screws of Proximal Femoral Nail System; Biomechanical Study
title_full Numerical Optimization of the Position in Femoral Head of Proximal Locking Screws of Proximal Femoral Nail System; Biomechanical Study
title_fullStr Numerical Optimization of the Position in Femoral Head of Proximal Locking Screws of Proximal Femoral Nail System; Biomechanical Study
title_full_unstemmed Numerical Optimization of the Position in Femoral Head of Proximal Locking Screws of Proximal Femoral Nail System; Biomechanical Study
title_short Numerical Optimization of the Position in Femoral Head of Proximal Locking Screws of Proximal Femoral Nail System; Biomechanical Study
title_sort numerical optimization of the position in femoral head of proximal locking screws of proximal femoral nail system; biomechanical study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5635629/
https://www.ncbi.nlm.nih.gov/pubmed/28443571
http://dx.doi.org/10.4274/balkanmedj.2016.0732
work_keys_str_mv AT konyamehmetnuri numericaloptimizationofthepositioninfemoralheadofproximallockingscrewsofproximalfemoralnailsystembiomechanicalstudy
AT verimozgur numericaloptimizationofthepositioninfemoralheadofproximallockingscrewsofproximalfemoralnailsystembiomechanicalstudy