Cargando…

Direct comparison of high‐temporal‐resolution CINE MRI with Doppler ultrasound for assessment of diastolic dysfunction in mice

Diastolic dysfunction is a sensitive early indicator of heart failure and can provide additional data to conventional measures of systolic function. Transmitral Doppler ultrasound, which measures the one‐dimensional flow of blood through the mitral valve, is currently the preferred method for the me...

Descripción completa

Detalles Bibliográficos
Autores principales: Roberts, Thomas A., Price, Anthony N., Jackson, Laurence H., Taylor, Valerie, David, Anna L., Lythgoe, Mark F., Stuckey, Daniel J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5638074/
https://www.ncbi.nlm.nih.gov/pubmed/28643891
http://dx.doi.org/10.1002/nbm.3763
_version_ 1783270691428106240
author Roberts, Thomas A.
Price, Anthony N.
Jackson, Laurence H.
Taylor, Valerie
David, Anna L.
Lythgoe, Mark F.
Stuckey, Daniel J.
author_facet Roberts, Thomas A.
Price, Anthony N.
Jackson, Laurence H.
Taylor, Valerie
David, Anna L.
Lythgoe, Mark F.
Stuckey, Daniel J.
author_sort Roberts, Thomas A.
collection PubMed
description Diastolic dysfunction is a sensitive early indicator of heart failure and can provide additional data to conventional measures of systolic function. Transmitral Doppler ultrasound, which measures the one‐dimensional flow of blood through the mitral valve, is currently the preferred method for the measurement of diastolic function, but the measurement of the left ventricular volume changes using high‐temporal‐resolution cinematic magnetic resonance imaging (CINE MRI) is an alternative approach which is emerging as a potentially more robust and user‐independent technique. Here, we investigated the performance of high‐temporal‐resolution CINE MRI and compared it with ultrasound for the detection of diastolic dysfunction in a mouse model of myocardial infarction. An in‐house, high‐temporal‐resolution, retrospectively gated CINE sequence was developed with a temporal resolution of 1 ms. Diastolic function in mice was assessed using a custom‐made, open‐source reconstruction package. Early (E) and late (A) left ventricular filling phases were easily identifiable, and these measurements were compared directly with high‐frequency, pulsed‐wave, Doppler ultrasound measurements of mitral valve inflow. A repeatability study established that high‐temporal‐resolution CINE MRI and Doppler ultrasound showed comparable accuracy when measuring E/A in normal control mice. However, when applied in a mouse model of myocardial infarction, high‐temporal‐resolution CINE MRI indicated diastolic heart failure (E/A = 0.94 ± 0.11), whereas ultrasound falsely detected normal cardiac function (E/A = 1.21 ± 0.11). The addition of high‐temporal‐resolution CINE MRI to preclinical imaging studies enhances the library of sequences available to cardiac researchers and potentially identifies diastolic heart failure early in disease progression.
format Online
Article
Text
id pubmed-5638074
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-56380742017-10-25 Direct comparison of high‐temporal‐resolution CINE MRI with Doppler ultrasound for assessment of diastolic dysfunction in mice Roberts, Thomas A. Price, Anthony N. Jackson, Laurence H. Taylor, Valerie David, Anna L. Lythgoe, Mark F. Stuckey, Daniel J. NMR Biomed Research Articles Diastolic dysfunction is a sensitive early indicator of heart failure and can provide additional data to conventional measures of systolic function. Transmitral Doppler ultrasound, which measures the one‐dimensional flow of blood through the mitral valve, is currently the preferred method for the measurement of diastolic function, but the measurement of the left ventricular volume changes using high‐temporal‐resolution cinematic magnetic resonance imaging (CINE MRI) is an alternative approach which is emerging as a potentially more robust and user‐independent technique. Here, we investigated the performance of high‐temporal‐resolution CINE MRI and compared it with ultrasound for the detection of diastolic dysfunction in a mouse model of myocardial infarction. An in‐house, high‐temporal‐resolution, retrospectively gated CINE sequence was developed with a temporal resolution of 1 ms. Diastolic function in mice was assessed using a custom‐made, open‐source reconstruction package. Early (E) and late (A) left ventricular filling phases were easily identifiable, and these measurements were compared directly with high‐frequency, pulsed‐wave, Doppler ultrasound measurements of mitral valve inflow. A repeatability study established that high‐temporal‐resolution CINE MRI and Doppler ultrasound showed comparable accuracy when measuring E/A in normal control mice. However, when applied in a mouse model of myocardial infarction, high‐temporal‐resolution CINE MRI indicated diastolic heart failure (E/A = 0.94 ± 0.11), whereas ultrasound falsely detected normal cardiac function (E/A = 1.21 ± 0.11). The addition of high‐temporal‐resolution CINE MRI to preclinical imaging studies enhances the library of sequences available to cardiac researchers and potentially identifies diastolic heart failure early in disease progression. John Wiley and Sons Inc. 2017-06-23 2017-10 /pmc/articles/PMC5638074/ /pubmed/28643891 http://dx.doi.org/10.1002/nbm.3763 Text en © 2017 The Authors. NMR in Biomedicine published by John Wiley & Sons Ltd. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Articles
Roberts, Thomas A.
Price, Anthony N.
Jackson, Laurence H.
Taylor, Valerie
David, Anna L.
Lythgoe, Mark F.
Stuckey, Daniel J.
Direct comparison of high‐temporal‐resolution CINE MRI with Doppler ultrasound for assessment of diastolic dysfunction in mice
title Direct comparison of high‐temporal‐resolution CINE MRI with Doppler ultrasound for assessment of diastolic dysfunction in mice
title_full Direct comparison of high‐temporal‐resolution CINE MRI with Doppler ultrasound for assessment of diastolic dysfunction in mice
title_fullStr Direct comparison of high‐temporal‐resolution CINE MRI with Doppler ultrasound for assessment of diastolic dysfunction in mice
title_full_unstemmed Direct comparison of high‐temporal‐resolution CINE MRI with Doppler ultrasound for assessment of diastolic dysfunction in mice
title_short Direct comparison of high‐temporal‐resolution CINE MRI with Doppler ultrasound for assessment of diastolic dysfunction in mice
title_sort direct comparison of high‐temporal‐resolution cine mri with doppler ultrasound for assessment of diastolic dysfunction in mice
topic Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5638074/
https://www.ncbi.nlm.nih.gov/pubmed/28643891
http://dx.doi.org/10.1002/nbm.3763
work_keys_str_mv AT robertsthomasa directcomparisonofhightemporalresolutioncinemriwithdopplerultrasoundforassessmentofdiastolicdysfunctioninmice
AT priceanthonyn directcomparisonofhightemporalresolutioncinemriwithdopplerultrasoundforassessmentofdiastolicdysfunctioninmice
AT jacksonlaurenceh directcomparisonofhightemporalresolutioncinemriwithdopplerultrasoundforassessmentofdiastolicdysfunctioninmice
AT taylorvalerie directcomparisonofhightemporalresolutioncinemriwithdopplerultrasoundforassessmentofdiastolicdysfunctioninmice
AT davidannal directcomparisonofhightemporalresolutioncinemriwithdopplerultrasoundforassessmentofdiastolicdysfunctioninmice
AT lythgoemarkf directcomparisonofhightemporalresolutioncinemriwithdopplerultrasoundforassessmentofdiastolicdysfunctioninmice
AT stuckeydanielj directcomparisonofhightemporalresolutioncinemriwithdopplerultrasoundforassessmentofdiastolicdysfunctioninmice