Cargando…

The association between photoreceptor layer thickness measured by optical coherence tomography and visual sensitivity in glaucomatous eyes

PURPOSE: To assess the thickness of the photoreceptor layer in the macular region in glaucomatous eyes. METHOD: Humphrey 10–2 visual field (VF) testing was carried out and mean threshold (mTH) was calculated in 118 eyes from 118 patients with open angle glaucoma. Macular optical coherence tomography...

Descripción completa

Detalles Bibliográficos
Autores principales: Asaoka, Ryo, Murata, Hiroshi, Yanagisawa, Mieko, Fujino, Yuri, Matsuura, Masato, Inoue, Tatsuya, Inoue, Kenji, Yamagami, Junkichi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5638206/
https://www.ncbi.nlm.nih.gov/pubmed/29023460
http://dx.doi.org/10.1371/journal.pone.0184064
_version_ 1783270706059935744
author Asaoka, Ryo
Murata, Hiroshi
Yanagisawa, Mieko
Fujino, Yuri
Matsuura, Masato
Inoue, Tatsuya
Inoue, Kenji
Yamagami, Junkichi
author_facet Asaoka, Ryo
Murata, Hiroshi
Yanagisawa, Mieko
Fujino, Yuri
Matsuura, Masato
Inoue, Tatsuya
Inoue, Kenji
Yamagami, Junkichi
author_sort Asaoka, Ryo
collection PubMed
description PURPOSE: To assess the thickness of the photoreceptor layer in the macular region in glaucomatous eyes. METHOD: Humphrey 10–2 visual field (VF) testing was carried out and mean threshold (mTH) was calculated in 118 eyes from 118 patients with open angle glaucoma. Macular optical coherence tomography (OCT) measurements (RS 3000, Nidek Co.ltd., Aichi, Japan) were also carried out in all eyes. Thickness measurements were recorded in the outer segment and retinal pigment epithelium (OS+RPE), the nerve fiber layer (NFL), the ganglion cell layer and inner plexiform layer (GCL+IPL), the inner nuclear layer and outer plexiform layer (INL+OPL) and the outer nuclear layer and inner segment (ONL+IS). The relationship between mTH and the thickness of these five different layers was investigated. Additionally, the influence of OS+RPE on mTH was investigated using partial correlation eliminating the effect of other variables of NFL, GCL+IPL, INL+OPL, ONL+IS, age, gender and axial length. RESULTS: The thickness of the OS+RPE layer was significantly decreased with the decrease of mTH (coefficient = 0.63 p <0.001). Partial correlation analysis suggested OS+RPE thickness is significantly (coefficient = 0.31, p <0.001) related to mTH, independent from NFL, GCL+IPL, INL+OPL, ONL+IS, age, gender and axial length. CONCLUSIONS: The thickness of the RPE+OS layer appears to be related to visual sensitivity in glaucoma.
format Online
Article
Text
id pubmed-5638206
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-56382062017-11-03 The association between photoreceptor layer thickness measured by optical coherence tomography and visual sensitivity in glaucomatous eyes Asaoka, Ryo Murata, Hiroshi Yanagisawa, Mieko Fujino, Yuri Matsuura, Masato Inoue, Tatsuya Inoue, Kenji Yamagami, Junkichi PLoS One Research Article PURPOSE: To assess the thickness of the photoreceptor layer in the macular region in glaucomatous eyes. METHOD: Humphrey 10–2 visual field (VF) testing was carried out and mean threshold (mTH) was calculated in 118 eyes from 118 patients with open angle glaucoma. Macular optical coherence tomography (OCT) measurements (RS 3000, Nidek Co.ltd., Aichi, Japan) were also carried out in all eyes. Thickness measurements were recorded in the outer segment and retinal pigment epithelium (OS+RPE), the nerve fiber layer (NFL), the ganglion cell layer and inner plexiform layer (GCL+IPL), the inner nuclear layer and outer plexiform layer (INL+OPL) and the outer nuclear layer and inner segment (ONL+IS). The relationship between mTH and the thickness of these five different layers was investigated. Additionally, the influence of OS+RPE on mTH was investigated using partial correlation eliminating the effect of other variables of NFL, GCL+IPL, INL+OPL, ONL+IS, age, gender and axial length. RESULTS: The thickness of the OS+RPE layer was significantly decreased with the decrease of mTH (coefficient = 0.63 p <0.001). Partial correlation analysis suggested OS+RPE thickness is significantly (coefficient = 0.31, p <0.001) related to mTH, independent from NFL, GCL+IPL, INL+OPL, ONL+IS, age, gender and axial length. CONCLUSIONS: The thickness of the RPE+OS layer appears to be related to visual sensitivity in glaucoma. Public Library of Science 2017-10-12 /pmc/articles/PMC5638206/ /pubmed/29023460 http://dx.doi.org/10.1371/journal.pone.0184064 Text en © 2017 Asaoka et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Asaoka, Ryo
Murata, Hiroshi
Yanagisawa, Mieko
Fujino, Yuri
Matsuura, Masato
Inoue, Tatsuya
Inoue, Kenji
Yamagami, Junkichi
The association between photoreceptor layer thickness measured by optical coherence tomography and visual sensitivity in glaucomatous eyes
title The association between photoreceptor layer thickness measured by optical coherence tomography and visual sensitivity in glaucomatous eyes
title_full The association between photoreceptor layer thickness measured by optical coherence tomography and visual sensitivity in glaucomatous eyes
title_fullStr The association between photoreceptor layer thickness measured by optical coherence tomography and visual sensitivity in glaucomatous eyes
title_full_unstemmed The association between photoreceptor layer thickness measured by optical coherence tomography and visual sensitivity in glaucomatous eyes
title_short The association between photoreceptor layer thickness measured by optical coherence tomography and visual sensitivity in glaucomatous eyes
title_sort association between photoreceptor layer thickness measured by optical coherence tomography and visual sensitivity in glaucomatous eyes
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5638206/
https://www.ncbi.nlm.nih.gov/pubmed/29023460
http://dx.doi.org/10.1371/journal.pone.0184064
work_keys_str_mv AT asaokaryo theassociationbetweenphotoreceptorlayerthicknessmeasuredbyopticalcoherencetomographyandvisualsensitivityinglaucomatouseyes
AT muratahiroshi theassociationbetweenphotoreceptorlayerthicknessmeasuredbyopticalcoherencetomographyandvisualsensitivityinglaucomatouseyes
AT yanagisawamieko theassociationbetweenphotoreceptorlayerthicknessmeasuredbyopticalcoherencetomographyandvisualsensitivityinglaucomatouseyes
AT fujinoyuri theassociationbetweenphotoreceptorlayerthicknessmeasuredbyopticalcoherencetomographyandvisualsensitivityinglaucomatouseyes
AT matsuuramasato theassociationbetweenphotoreceptorlayerthicknessmeasuredbyopticalcoherencetomographyandvisualsensitivityinglaucomatouseyes
AT inouetatsuya theassociationbetweenphotoreceptorlayerthicknessmeasuredbyopticalcoherencetomographyandvisualsensitivityinglaucomatouseyes
AT inouekenji theassociationbetweenphotoreceptorlayerthicknessmeasuredbyopticalcoherencetomographyandvisualsensitivityinglaucomatouseyes
AT yamagamijunkichi theassociationbetweenphotoreceptorlayerthicknessmeasuredbyopticalcoherencetomographyandvisualsensitivityinglaucomatouseyes
AT asaokaryo associationbetweenphotoreceptorlayerthicknessmeasuredbyopticalcoherencetomographyandvisualsensitivityinglaucomatouseyes
AT muratahiroshi associationbetweenphotoreceptorlayerthicknessmeasuredbyopticalcoherencetomographyandvisualsensitivityinglaucomatouseyes
AT yanagisawamieko associationbetweenphotoreceptorlayerthicknessmeasuredbyopticalcoherencetomographyandvisualsensitivityinglaucomatouseyes
AT fujinoyuri associationbetweenphotoreceptorlayerthicknessmeasuredbyopticalcoherencetomographyandvisualsensitivityinglaucomatouseyes
AT matsuuramasato associationbetweenphotoreceptorlayerthicknessmeasuredbyopticalcoherencetomographyandvisualsensitivityinglaucomatouseyes
AT inouetatsuya associationbetweenphotoreceptorlayerthicknessmeasuredbyopticalcoherencetomographyandvisualsensitivityinglaucomatouseyes
AT inouekenji associationbetweenphotoreceptorlayerthicknessmeasuredbyopticalcoherencetomographyandvisualsensitivityinglaucomatouseyes
AT yamagamijunkichi associationbetweenphotoreceptorlayerthicknessmeasuredbyopticalcoherencetomographyandvisualsensitivityinglaucomatouseyes