Cargando…

Influence of platinum harmonized textile on neuromuscular, systemic and subjective recovery

The clothing manufacturer Venex Life-Science tracks the strategy to enhance recovery process through implementing platinum harmonized technology (PHT) into their Venex(®) Regeneration Wear. The proposed mechanisms of the regeneration wear are an increase of parasympathetic activity and an increase o...

Descripción completa

Detalles Bibliográficos
Autores principales: Zinke, Fridolin, Bakenecker, Patrick, Hahn, Daniel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5638408/
https://www.ncbi.nlm.nih.gov/pubmed/29023563
http://dx.doi.org/10.1371/journal.pone.0186162
_version_ 1783270732726272000
author Zinke, Fridolin
Bakenecker, Patrick
Hahn, Daniel
author_facet Zinke, Fridolin
Bakenecker, Patrick
Hahn, Daniel
author_sort Zinke, Fridolin
collection PubMed
description The clothing manufacturer Venex Life-Science tracks the strategy to enhance recovery process through implementing platinum harmonized technology (PHT) into their Venex(®) Regeneration Wear. The proposed mechanisms of the regeneration wear are an increase of parasympathetic activity and an increase of the temperature due far-infrared radiation. The purpose of this study was to investigate potential effects of Venex regeneration wear on the recovery of neuromuscular, systemic and subjective parameters following exercise. In a randomized, single-blinded cross-over design, 13 strength-trained male participants performed two exercise sessions in one day. After the first exercise session and for 3 nights following the exercise day participants wore the Venex regeneration wear or a placebo product. Measures of isometric maximum voluntary contraction (MVC), voluntary activation (VA) and potentiated twitch torque (PTT) of the knee extensors, as well as maximum jump height during the Counter-Movement and Drop Jump, creatinkinase (CK) and subjective parameters (perceived pain, recovery condition and sleep quality) were obtained before and after each exercise session and 24, 48, and 72 hours after the first exercise session. MVC, PTT, CK and jump parameters changed over time during the exercise day as well as on the following days, however, there were no significant differences between treatments. Subjective parameters showed strong effect sizes (i. e. Cohen’s d > 0.6) in favor for Venex but no significant differences between treatments. Based on these findings, it is concluded that wearing a platinum harmonized textile following exercise did not improve neuromuscular and systemic recovery in a trained male population to a statistical noticeable extent. However, the findings for the subjective parameters suggest some potential for enhanced recovery that requires further research.
format Online
Article
Text
id pubmed-5638408
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-56384082017-10-20 Influence of platinum harmonized textile on neuromuscular, systemic and subjective recovery Zinke, Fridolin Bakenecker, Patrick Hahn, Daniel PLoS One Research Article The clothing manufacturer Venex Life-Science tracks the strategy to enhance recovery process through implementing platinum harmonized technology (PHT) into their Venex(®) Regeneration Wear. The proposed mechanisms of the regeneration wear are an increase of parasympathetic activity and an increase of the temperature due far-infrared radiation. The purpose of this study was to investigate potential effects of Venex regeneration wear on the recovery of neuromuscular, systemic and subjective parameters following exercise. In a randomized, single-blinded cross-over design, 13 strength-trained male participants performed two exercise sessions in one day. After the first exercise session and for 3 nights following the exercise day participants wore the Venex regeneration wear or a placebo product. Measures of isometric maximum voluntary contraction (MVC), voluntary activation (VA) and potentiated twitch torque (PTT) of the knee extensors, as well as maximum jump height during the Counter-Movement and Drop Jump, creatinkinase (CK) and subjective parameters (perceived pain, recovery condition and sleep quality) were obtained before and after each exercise session and 24, 48, and 72 hours after the first exercise session. MVC, PTT, CK and jump parameters changed over time during the exercise day as well as on the following days, however, there were no significant differences between treatments. Subjective parameters showed strong effect sizes (i. e. Cohen’s d > 0.6) in favor for Venex but no significant differences between treatments. Based on these findings, it is concluded that wearing a platinum harmonized textile following exercise did not improve neuromuscular and systemic recovery in a trained male population to a statistical noticeable extent. However, the findings for the subjective parameters suggest some potential for enhanced recovery that requires further research. Public Library of Science 2017-10-12 /pmc/articles/PMC5638408/ /pubmed/29023563 http://dx.doi.org/10.1371/journal.pone.0186162 Text en © 2017 Zinke et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Zinke, Fridolin
Bakenecker, Patrick
Hahn, Daniel
Influence of platinum harmonized textile on neuromuscular, systemic and subjective recovery
title Influence of platinum harmonized textile on neuromuscular, systemic and subjective recovery
title_full Influence of platinum harmonized textile on neuromuscular, systemic and subjective recovery
title_fullStr Influence of platinum harmonized textile on neuromuscular, systemic and subjective recovery
title_full_unstemmed Influence of platinum harmonized textile on neuromuscular, systemic and subjective recovery
title_short Influence of platinum harmonized textile on neuromuscular, systemic and subjective recovery
title_sort influence of platinum harmonized textile on neuromuscular, systemic and subjective recovery
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5638408/
https://www.ncbi.nlm.nih.gov/pubmed/29023563
http://dx.doi.org/10.1371/journal.pone.0186162
work_keys_str_mv AT zinkefridolin influenceofplatinumharmonizedtextileonneuromuscularsystemicandsubjectiverecovery
AT bakeneckerpatrick influenceofplatinumharmonizedtextileonneuromuscularsystemicandsubjectiverecovery
AT hahndaniel influenceofplatinumharmonizedtextileonneuromuscularsystemicandsubjectiverecovery