ISQ calculation evaluation of in vitro laser scanning vibrometry-captured resonance frequency

BACKGROUND: Implant stability testing at various stages of implant therapy by means of resonance frequency analysis is extensively used. The overall measurement outcome is a function of the resulting stiffness of three entities: surrounding bone, bone-implant complex, and implant-Smartpeg complex. T...

Descripción completa

Detalles Bibliográficos
Autores principales: Debruyne, Stijn, Grognard, Nicolas, Verleye, Gino, Van Massenhove, Korneel, Mavreas, Dimitrios, Vannet, Bart Vande
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5638766/
https://www.ncbi.nlm.nih.gov/pubmed/29027158
http://dx.doi.org/10.1186/s40729-017-0105-3
_version_ 1783270768595959808
author Debruyne, Stijn
Grognard, Nicolas
Verleye, Gino
Van Massenhove, Korneel
Mavreas, Dimitrios
Vannet, Bart Vande
author_facet Debruyne, Stijn
Grognard, Nicolas
Verleye, Gino
Van Massenhove, Korneel
Mavreas, Dimitrios
Vannet, Bart Vande
author_sort Debruyne, Stijn
collection PubMed
description BACKGROUND: Implant stability testing at various stages of implant therapy by means of resonance frequency analysis is extensively used. The overall measurement outcome is a function of the resulting stiffness of three entities: surrounding bone, bone-implant complex, and implant-Smartpeg complex. The influence of the latter on the overall measurement results is presently unknown. It can be investigated in vitro by use of imbedded implants with mounted Smartpegs. This enables to keep the influence of the two other entities constant and controlled. The purpose of this study is to verify if a laboratory laser Doppler vibrometry technology-based procedure results in comparable ISQ results after calculation of captured resonance frequency spectra by aid of the Osstell algorithm with direct Osstell IDX device measurements. METHODS: A laboratory procedure was engineered to record frequency spectra of resin-imbedded test implants with mounted Smartpegs, after electromagnetic excitation with the Osstell IDX device and laser Doppler vibrometry response detection. Fast Fourier transformation data processing of resonance frequency data resulted in determination of a maximum resonance frequency values allowing calculation of implant stability quotient (ISQ) values using the Osstell algorithm. RESULTS: Laboratory-based ISQ values were compared to Osstell IDx device-generated ISQ values for Straumann tissue level, Ankylos, and 3i Certain implant systems. For both systems, a correlation coefficient r = 0.99 was found. Furthermore, a clinically rejectable mean difference of 0.09 ISQ units was noted between both datasets. CONCLUSIONS: The proposed laboratory method with the application of the Osstell algorithm for ISQ calculation is appropriate for future studies to in vitro research aspects of resonance frequency analysis implant stability measurements.
format Online
Article
Text
id pubmed-5638766
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-56387662017-10-24 ISQ calculation evaluation of in vitro laser scanning vibrometry-captured resonance frequency Debruyne, Stijn Grognard, Nicolas Verleye, Gino Van Massenhove, Korneel Mavreas, Dimitrios Vannet, Bart Vande Int J Implant Dent Research BACKGROUND: Implant stability testing at various stages of implant therapy by means of resonance frequency analysis is extensively used. The overall measurement outcome is a function of the resulting stiffness of three entities: surrounding bone, bone-implant complex, and implant-Smartpeg complex. The influence of the latter on the overall measurement results is presently unknown. It can be investigated in vitro by use of imbedded implants with mounted Smartpegs. This enables to keep the influence of the two other entities constant and controlled. The purpose of this study is to verify if a laboratory laser Doppler vibrometry technology-based procedure results in comparable ISQ results after calculation of captured resonance frequency spectra by aid of the Osstell algorithm with direct Osstell IDX device measurements. METHODS: A laboratory procedure was engineered to record frequency spectra of resin-imbedded test implants with mounted Smartpegs, after electromagnetic excitation with the Osstell IDX device and laser Doppler vibrometry response detection. Fast Fourier transformation data processing of resonance frequency data resulted in determination of a maximum resonance frequency values allowing calculation of implant stability quotient (ISQ) values using the Osstell algorithm. RESULTS: Laboratory-based ISQ values were compared to Osstell IDx device-generated ISQ values for Straumann tissue level, Ankylos, and 3i Certain implant systems. For both systems, a correlation coefficient r = 0.99 was found. Furthermore, a clinically rejectable mean difference of 0.09 ISQ units was noted between both datasets. CONCLUSIONS: The proposed laboratory method with the application of the Osstell algorithm for ISQ calculation is appropriate for future studies to in vitro research aspects of resonance frequency analysis implant stability measurements. Springer Berlin Heidelberg 2017-10-12 /pmc/articles/PMC5638766/ /pubmed/29027158 http://dx.doi.org/10.1186/s40729-017-0105-3 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Research
Debruyne, Stijn
Grognard, Nicolas
Verleye, Gino
Van Massenhove, Korneel
Mavreas, Dimitrios
Vannet, Bart Vande
ISQ calculation evaluation of in vitro laser scanning vibrometry-captured resonance frequency
title ISQ calculation evaluation of in vitro laser scanning vibrometry-captured resonance frequency
title_full ISQ calculation evaluation of in vitro laser scanning vibrometry-captured resonance frequency
title_fullStr ISQ calculation evaluation of in vitro laser scanning vibrometry-captured resonance frequency
title_full_unstemmed ISQ calculation evaluation of in vitro laser scanning vibrometry-captured resonance frequency
title_short ISQ calculation evaluation of in vitro laser scanning vibrometry-captured resonance frequency
title_sort isq calculation evaluation of in vitro laser scanning vibrometry-captured resonance frequency
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5638766/
https://www.ncbi.nlm.nih.gov/pubmed/29027158
http://dx.doi.org/10.1186/s40729-017-0105-3
work_keys_str_mv AT debruynestijn isqcalculationevaluationofinvitrolaserscanningvibrometrycapturedresonancefrequency
AT grognardnicolas isqcalculationevaluationofinvitrolaserscanningvibrometrycapturedresonancefrequency
AT verleyegino isqcalculationevaluationofinvitrolaserscanningvibrometrycapturedresonancefrequency
AT vanmassenhovekorneel isqcalculationevaluationofinvitrolaserscanningvibrometrycapturedresonancefrequency
AT mavreasdimitrios isqcalculationevaluationofinvitrolaserscanningvibrometrycapturedresonancefrequency
AT vannetbartvande isqcalculationevaluationofinvitrolaserscanningvibrometrycapturedresonancefrequency