Advantages and Disadvantages of Multi-axis Intraoperative Angiography Unit for Percutaneous Pedicle Screw Placement in the Lumbar Spine
We analyzed clinical usefulness of the high resolution imaging system in a hybrid operation room (OR) for posterior lumbar interbody fusion. A total of 17 patients with lumbar spondylolisthesis between February 2014 and August 2016 were included. Multi-axis imaging system in a hybrid OR was used in...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Japan Neurosurgical Society
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5638792/ https://www.ncbi.nlm.nih.gov/pubmed/28768918 http://dx.doi.org/10.2176/nmc.oa.2017-0059 |
_version_ | 1783270774853861376 |
---|---|
author | KAGEYAMA, Hiroto YOSHIMURA, Shinichi UCHIDA, Kazutaka IIDA, Tomoko |
author_facet | KAGEYAMA, Hiroto YOSHIMURA, Shinichi UCHIDA, Kazutaka IIDA, Tomoko |
author_sort | KAGEYAMA, Hiroto |
collection | PubMed |
description | We analyzed clinical usefulness of the high resolution imaging system in a hybrid operation room (OR) for posterior lumbar interbody fusion. A total of 17 patients with lumbar spondylolisthesis between February 2014 and August 2016 were included. Multi-axis imaging system in a hybrid OR was used in 12 patients (hybrid OR group); the conventional C-arm fluoroscopy, in 5 patients (C-arm group). The time to confirm the first percutaneous pedicle screw (PPS) angle (hybrid OR, 80 vs C-arm, 249 s; P = 0.0026) and the second to the last PPS angle (77 vs 90 s; P = 0.040) were shorter in the hybrid OR group. Placement accuracy was higher in the hybrid OR group (88.0 vs 59.1%; P = 0.010). Irradiation dose was significantly lower in the C-arm group (462 vs 102 mGy; P = 0.0013). This study suggested that the accuracy of PPS placement and time to confirm the PPS angle are the advantages in a hybrid OR. |
format | Online Article Text |
id | pubmed-5638792 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | The Japan Neurosurgical Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-56387922017-10-16 Advantages and Disadvantages of Multi-axis Intraoperative Angiography Unit for Percutaneous Pedicle Screw Placement in the Lumbar Spine KAGEYAMA, Hiroto YOSHIMURA, Shinichi UCHIDA, Kazutaka IIDA, Tomoko Neurol Med Chir (Tokyo) Original Article We analyzed clinical usefulness of the high resolution imaging system in a hybrid operation room (OR) for posterior lumbar interbody fusion. A total of 17 patients with lumbar spondylolisthesis between February 2014 and August 2016 were included. Multi-axis imaging system in a hybrid OR was used in 12 patients (hybrid OR group); the conventional C-arm fluoroscopy, in 5 patients (C-arm group). The time to confirm the first percutaneous pedicle screw (PPS) angle (hybrid OR, 80 vs C-arm, 249 s; P = 0.0026) and the second to the last PPS angle (77 vs 90 s; P = 0.040) were shorter in the hybrid OR group. Placement accuracy was higher in the hybrid OR group (88.0 vs 59.1%; P = 0.010). Irradiation dose was significantly lower in the C-arm group (462 vs 102 mGy; P = 0.0013). This study suggested that the accuracy of PPS placement and time to confirm the PPS angle are the advantages in a hybrid OR. The Japan Neurosurgical Society 2017-09 2017-08-01 /pmc/articles/PMC5638792/ /pubmed/28768918 http://dx.doi.org/10.2176/nmc.oa.2017-0059 Text en © 2017 The Japan Neurosurgical Society This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-nd/4.0/ |
spellingShingle | Original Article KAGEYAMA, Hiroto YOSHIMURA, Shinichi UCHIDA, Kazutaka IIDA, Tomoko Advantages and Disadvantages of Multi-axis Intraoperative Angiography Unit for Percutaneous Pedicle Screw Placement in the Lumbar Spine |
title | Advantages and Disadvantages of Multi-axis Intraoperative Angiography Unit for Percutaneous Pedicle Screw Placement in the Lumbar Spine |
title_full | Advantages and Disadvantages of Multi-axis Intraoperative Angiography Unit for Percutaneous Pedicle Screw Placement in the Lumbar Spine |
title_fullStr | Advantages and Disadvantages of Multi-axis Intraoperative Angiography Unit for Percutaneous Pedicle Screw Placement in the Lumbar Spine |
title_full_unstemmed | Advantages and Disadvantages of Multi-axis Intraoperative Angiography Unit for Percutaneous Pedicle Screw Placement in the Lumbar Spine |
title_short | Advantages and Disadvantages of Multi-axis Intraoperative Angiography Unit for Percutaneous Pedicle Screw Placement in the Lumbar Spine |
title_sort | advantages and disadvantages of multi-axis intraoperative angiography unit for percutaneous pedicle screw placement in the lumbar spine |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5638792/ https://www.ncbi.nlm.nih.gov/pubmed/28768918 http://dx.doi.org/10.2176/nmc.oa.2017-0059 |
work_keys_str_mv | AT kageyamahiroto advantagesanddisadvantagesofmultiaxisintraoperativeangiographyunitforpercutaneouspediclescrewplacementinthelumbarspine AT yoshimurashinichi advantagesanddisadvantagesofmultiaxisintraoperativeangiographyunitforpercutaneouspediclescrewplacementinthelumbarspine AT uchidakazutaka advantagesanddisadvantagesofmultiaxisintraoperativeangiographyunitforpercutaneouspediclescrewplacementinthelumbarspine AT iidatomoko advantagesanddisadvantagesofmultiaxisintraoperativeangiographyunitforpercutaneouspediclescrewplacementinthelumbarspine |