Cargando…

Prospective Validation of Intra- and Interobserver Reproducibility of a New Point Shear Wave Elastographic Technique for Assessing Liver Stiffness in Patients with Chronic Liver Disease

OBJECTIVE: To assess intra- and inter-observer reproducibility of a new point shear wave elastography technique (pSWE, S-Shearwave, Samsung Medison) and compare its accuracy in assessing liver stiffness (LS) with an established pSWE technique (Virtual Touch Quantification, VTQ). MATERIALS AND METHOD...

Descripción completa

Detalles Bibliográficos
Autores principales: Ahn, Su Joa, Lee, Jeong Min, Chang, Won, Lee, Sang Min, Kang, Hyo-Jin, Yang, Hyunkyung, Yoon, Jeong Hee, Park, Sae Jin, Han, Joon Koo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5639158/
https://www.ncbi.nlm.nih.gov/pubmed/29089825
http://dx.doi.org/10.3348/kjr.2017.18.6.926
_version_ 1783270838833774592
author Ahn, Su Joa
Lee, Jeong Min
Chang, Won
Lee, Sang Min
Kang, Hyo-Jin
Yang, Hyunkyung
Yoon, Jeong Hee
Park, Sae Jin
Han, Joon Koo
author_facet Ahn, Su Joa
Lee, Jeong Min
Chang, Won
Lee, Sang Min
Kang, Hyo-Jin
Yang, Hyunkyung
Yoon, Jeong Hee
Park, Sae Jin
Han, Joon Koo
author_sort Ahn, Su Joa
collection PubMed
description OBJECTIVE: To assess intra- and inter-observer reproducibility of a new point shear wave elastography technique (pSWE, S-Shearwave, Samsung Medison) and compare its accuracy in assessing liver stiffness (LS) with an established pSWE technique (Virtual Touch Quantification, VTQ). MATERIALS AND METHODS: Thirty-three patients were enrolled in this Institutional Review Board-approved prospective study. LS values were measured by VTQ on an Acuson S2000 system (Siemens Healthineer) and S-Shearwave on an RS-80A (Samsung Medison) in the same session, followed by two further S-Shearwave sessions for inter- and intra-observer variation at 8-hour intervals. The technical success rate (SR) and reliability of the measurements of both pSWE techniques were compared. The intra- and inter-observer reproducibility of S-Shearwave was determined by intraclass correlation coefficients (ICCs). LS values were measured by both methods of pSWE. The diagnostic performance in severe fibrosis (F ≥ 3) and cirrhosis (F = 4) was evaluated using the receiver operating characteristics curve analysis and the Obuchowski measure with the LS values of transient elastography as the referenced standard. RESULTS: The VTQ (100%, 33/33) and S-Shearwave (96.9%, 32/33) techniques did not display a significant difference in technical SR (p = 0.63) or reliability of LS measurements (96.9%, 32/33; 93.9%, 30/32, respectively, p = 0.61). The inter- and intra-observer agreement for LS measurements using the S-Shearwave technique was excellent (ICC = 0.98 and 0.99, respectively). The mean LS values of both pSWE techniques were not significantly different and exhibited a good correlation (r = 0.78). To detect F ≥ 3 and F = 4, VTQ and S-Shearwave showed comparable diagnostic accuracy as indicated by the following outcomes: areas under receiver operating characteristics curve (AUROC) = 0.87 (95% confidence intervals [CI] 0.70–0.96), 0.89 for VTQ (95% CI 0.74–0.97), respectively; and AUROC = 0.84 (95% CI 0.67–0.94), 0.94 (95% CI 0.80–0.99) for S-Shearwave (p > 0.48), respectively. The Obuchowski measures were similarly high for S-Shearwave and VTQ (0.94 vs. 0.95). CONCLUSION: S-Shearwave shows excellent inter- and intra-observer agreement and diagnostic effectiveness comparable to VTQ in detecting LS.
format Online
Article
Text
id pubmed-5639158
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-56391582017-11-01 Prospective Validation of Intra- and Interobserver Reproducibility of a New Point Shear Wave Elastographic Technique for Assessing Liver Stiffness in Patients with Chronic Liver Disease Ahn, Su Joa Lee, Jeong Min Chang, Won Lee, Sang Min Kang, Hyo-Jin Yang, Hyunkyung Yoon, Jeong Hee Park, Sae Jin Han, Joon Koo Korean J Radiol Gastrointestinal Imaging OBJECTIVE: To assess intra- and inter-observer reproducibility of a new point shear wave elastography technique (pSWE, S-Shearwave, Samsung Medison) and compare its accuracy in assessing liver stiffness (LS) with an established pSWE technique (Virtual Touch Quantification, VTQ). MATERIALS AND METHODS: Thirty-three patients were enrolled in this Institutional Review Board-approved prospective study. LS values were measured by VTQ on an Acuson S2000 system (Siemens Healthineer) and S-Shearwave on an RS-80A (Samsung Medison) in the same session, followed by two further S-Shearwave sessions for inter- and intra-observer variation at 8-hour intervals. The technical success rate (SR) and reliability of the measurements of both pSWE techniques were compared. The intra- and inter-observer reproducibility of S-Shearwave was determined by intraclass correlation coefficients (ICCs). LS values were measured by both methods of pSWE. The diagnostic performance in severe fibrosis (F ≥ 3) and cirrhosis (F = 4) was evaluated using the receiver operating characteristics curve analysis and the Obuchowski measure with the LS values of transient elastography as the referenced standard. RESULTS: The VTQ (100%, 33/33) and S-Shearwave (96.9%, 32/33) techniques did not display a significant difference in technical SR (p = 0.63) or reliability of LS measurements (96.9%, 32/33; 93.9%, 30/32, respectively, p = 0.61). The inter- and intra-observer agreement for LS measurements using the S-Shearwave technique was excellent (ICC = 0.98 and 0.99, respectively). The mean LS values of both pSWE techniques were not significantly different and exhibited a good correlation (r = 0.78). To detect F ≥ 3 and F = 4, VTQ and S-Shearwave showed comparable diagnostic accuracy as indicated by the following outcomes: areas under receiver operating characteristics curve (AUROC) = 0.87 (95% confidence intervals [CI] 0.70–0.96), 0.89 for VTQ (95% CI 0.74–0.97), respectively; and AUROC = 0.84 (95% CI 0.67–0.94), 0.94 (95% CI 0.80–0.99) for S-Shearwave (p > 0.48), respectively. The Obuchowski measures were similarly high for S-Shearwave and VTQ (0.94 vs. 0.95). CONCLUSION: S-Shearwave shows excellent inter- and intra-observer agreement and diagnostic effectiveness comparable to VTQ in detecting LS. The Korean Society of Radiology 2017 2017-09-21 /pmc/articles/PMC5639158/ /pubmed/29089825 http://dx.doi.org/10.3348/kjr.2017.18.6.926 Text en Copyright © 2017 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Gastrointestinal Imaging
Ahn, Su Joa
Lee, Jeong Min
Chang, Won
Lee, Sang Min
Kang, Hyo-Jin
Yang, Hyunkyung
Yoon, Jeong Hee
Park, Sae Jin
Han, Joon Koo
Prospective Validation of Intra- and Interobserver Reproducibility of a New Point Shear Wave Elastographic Technique for Assessing Liver Stiffness in Patients with Chronic Liver Disease
title Prospective Validation of Intra- and Interobserver Reproducibility of a New Point Shear Wave Elastographic Technique for Assessing Liver Stiffness in Patients with Chronic Liver Disease
title_full Prospective Validation of Intra- and Interobserver Reproducibility of a New Point Shear Wave Elastographic Technique for Assessing Liver Stiffness in Patients with Chronic Liver Disease
title_fullStr Prospective Validation of Intra- and Interobserver Reproducibility of a New Point Shear Wave Elastographic Technique for Assessing Liver Stiffness in Patients with Chronic Liver Disease
title_full_unstemmed Prospective Validation of Intra- and Interobserver Reproducibility of a New Point Shear Wave Elastographic Technique for Assessing Liver Stiffness in Patients with Chronic Liver Disease
title_short Prospective Validation of Intra- and Interobserver Reproducibility of a New Point Shear Wave Elastographic Technique for Assessing Liver Stiffness in Patients with Chronic Liver Disease
title_sort prospective validation of intra- and interobserver reproducibility of a new point shear wave elastographic technique for assessing liver stiffness in patients with chronic liver disease
topic Gastrointestinal Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5639158/
https://www.ncbi.nlm.nih.gov/pubmed/29089825
http://dx.doi.org/10.3348/kjr.2017.18.6.926
work_keys_str_mv AT ahnsujoa prospectivevalidationofintraandinterobserverreproducibilityofanewpointshearwaveelastographictechniqueforassessingliverstiffnessinpatientswithchronicliverdisease
AT leejeongmin prospectivevalidationofintraandinterobserverreproducibilityofanewpointshearwaveelastographictechniqueforassessingliverstiffnessinpatientswithchronicliverdisease
AT changwon prospectivevalidationofintraandinterobserverreproducibilityofanewpointshearwaveelastographictechniqueforassessingliverstiffnessinpatientswithchronicliverdisease
AT leesangmin prospectivevalidationofintraandinterobserverreproducibilityofanewpointshearwaveelastographictechniqueforassessingliverstiffnessinpatientswithchronicliverdisease
AT kanghyojin prospectivevalidationofintraandinterobserverreproducibilityofanewpointshearwaveelastographictechniqueforassessingliverstiffnessinpatientswithchronicliverdisease
AT yanghyunkyung prospectivevalidationofintraandinterobserverreproducibilityofanewpointshearwaveelastographictechniqueforassessingliverstiffnessinpatientswithchronicliverdisease
AT yoonjeonghee prospectivevalidationofintraandinterobserverreproducibilityofanewpointshearwaveelastographictechniqueforassessingliverstiffnessinpatientswithchronicliverdisease
AT parksaejin prospectivevalidationofintraandinterobserverreproducibilityofanewpointshearwaveelastographictechniqueforassessingliverstiffnessinpatientswithchronicliverdisease
AT hanjoonkoo prospectivevalidationofintraandinterobserverreproducibilityofanewpointshearwaveelastographictechniqueforassessingliverstiffnessinpatientswithchronicliverdisease