Cargando…

Qualitative and Quantitative Comparison of Contrast-Enhanced Fluid-Attenuated Inversion Recovery, Magnetization Transfer Spin Echo, and Fat-Saturation T1-Weighted Sequences in Infectious Meningitis

OBJECTIVE: To compare the contrast-enhanced fluid-attenuated inversion recovery (CE-FLAIR), the CE T1-weighted (CE-T1W) sequence with fat suppression (FS) and magnetization transfer (MT) for early detection and characterization of infectious meningitis. MATERIALS AND METHODS: Fifty patients and 10 c...

Descripción completa

Detalles Bibliográficos
Autores principales: Azad, Rajiv, Tayal, Mohit, Azad, Sheenam, Sharma, Garima, Srivastava, Rajendra Kumar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5639163/
https://www.ncbi.nlm.nih.gov/pubmed/29089830
http://dx.doi.org/10.3348/kjr.2017.18.6.973
_version_ 1783270840021811200
author Azad, Rajiv
Tayal, Mohit
Azad, Sheenam
Sharma, Garima
Srivastava, Rajendra Kumar
author_facet Azad, Rajiv
Tayal, Mohit
Azad, Sheenam
Sharma, Garima
Srivastava, Rajendra Kumar
author_sort Azad, Rajiv
collection PubMed
description OBJECTIVE: To compare the contrast-enhanced fluid-attenuated inversion recovery (CE-FLAIR), the CE T1-weighted (CE-T1W) sequence with fat suppression (FS) and magnetization transfer (MT) for early detection and characterization of infectious meningitis. MATERIALS AND METHODS: Fifty patients and 10 control subjects were evaluated with the CE-FLAIR and the CE-T1W sequences with FS and MT. Qualitative assessment was done by two observers for presence and grading of abnormal leptomeningeal enhancement. Quantitative assessment included computation of net meningeal enhancement, using single pixel signal intensity software. A newly devised FLAIR based scoring system, based on certain imaging features including ventricular dilatation, ependymal enhancement, infarcts and subdural effusions was used to indicate the etiology. Data were analysed using the Student's t test, Cohen's Kappa coefficient, Pearson's correlation coefficient, the intraclass correlation coefficient, one way analysis of variance, and Fisher's exact test with Bonferroni correction as the post hoc test. RESULTS: The CE-FLAIR sequence demonstrated a better sensitivity (100%), diagnostic accuracy (95%), and a stronger correlation with the cerebrospinal fluid, total leukocyte count (r = 0.75), protein (r = 0.77), adenosine deaminase (r = 0.81) and blood glucose (r = -0.6) values compared to the CE-T1W sequences. Qualitative grades and quantitative meningeal enhancement on the CE-FLAIR sequence were also significantly greater than those on the other sequences. The FLAIR based scoring system yielded a diagnostic accuracy of 91.6% and a sensitivity of 96%. A strong inverse Pearson's correlation (r = -0.95) was found between the assigned score and patient's Glasgow Coma Scale at the time of admission. CONCLUSION: The CE-FLAIR sequence is better suited for evaluating infectious meningitis and could be included as a part of the routine MR imaging protocol.
format Online
Article
Text
id pubmed-5639163
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-56391632017-11-01 Qualitative and Quantitative Comparison of Contrast-Enhanced Fluid-Attenuated Inversion Recovery, Magnetization Transfer Spin Echo, and Fat-Saturation T1-Weighted Sequences in Infectious Meningitis Azad, Rajiv Tayal, Mohit Azad, Sheenam Sharma, Garima Srivastava, Rajendra Kumar Korean J Radiol Neuroimaging and Head & Neck OBJECTIVE: To compare the contrast-enhanced fluid-attenuated inversion recovery (CE-FLAIR), the CE T1-weighted (CE-T1W) sequence with fat suppression (FS) and magnetization transfer (MT) for early detection and characterization of infectious meningitis. MATERIALS AND METHODS: Fifty patients and 10 control subjects were evaluated with the CE-FLAIR and the CE-T1W sequences with FS and MT. Qualitative assessment was done by two observers for presence and grading of abnormal leptomeningeal enhancement. Quantitative assessment included computation of net meningeal enhancement, using single pixel signal intensity software. A newly devised FLAIR based scoring system, based on certain imaging features including ventricular dilatation, ependymal enhancement, infarcts and subdural effusions was used to indicate the etiology. Data were analysed using the Student's t test, Cohen's Kappa coefficient, Pearson's correlation coefficient, the intraclass correlation coefficient, one way analysis of variance, and Fisher's exact test with Bonferroni correction as the post hoc test. RESULTS: The CE-FLAIR sequence demonstrated a better sensitivity (100%), diagnostic accuracy (95%), and a stronger correlation with the cerebrospinal fluid, total leukocyte count (r = 0.75), protein (r = 0.77), adenosine deaminase (r = 0.81) and blood glucose (r = -0.6) values compared to the CE-T1W sequences. Qualitative grades and quantitative meningeal enhancement on the CE-FLAIR sequence were also significantly greater than those on the other sequences. The FLAIR based scoring system yielded a diagnostic accuracy of 91.6% and a sensitivity of 96%. A strong inverse Pearson's correlation (r = -0.95) was found between the assigned score and patient's Glasgow Coma Scale at the time of admission. CONCLUSION: The CE-FLAIR sequence is better suited for evaluating infectious meningitis and could be included as a part of the routine MR imaging protocol. The Korean Society of Radiology 2017 2017-09-21 /pmc/articles/PMC5639163/ /pubmed/29089830 http://dx.doi.org/10.3348/kjr.2017.18.6.973 Text en Copyright © 2017 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Neuroimaging and Head & Neck
Azad, Rajiv
Tayal, Mohit
Azad, Sheenam
Sharma, Garima
Srivastava, Rajendra Kumar
Qualitative and Quantitative Comparison of Contrast-Enhanced Fluid-Attenuated Inversion Recovery, Magnetization Transfer Spin Echo, and Fat-Saturation T1-Weighted Sequences in Infectious Meningitis
title Qualitative and Quantitative Comparison of Contrast-Enhanced Fluid-Attenuated Inversion Recovery, Magnetization Transfer Spin Echo, and Fat-Saturation T1-Weighted Sequences in Infectious Meningitis
title_full Qualitative and Quantitative Comparison of Contrast-Enhanced Fluid-Attenuated Inversion Recovery, Magnetization Transfer Spin Echo, and Fat-Saturation T1-Weighted Sequences in Infectious Meningitis
title_fullStr Qualitative and Quantitative Comparison of Contrast-Enhanced Fluid-Attenuated Inversion Recovery, Magnetization Transfer Spin Echo, and Fat-Saturation T1-Weighted Sequences in Infectious Meningitis
title_full_unstemmed Qualitative and Quantitative Comparison of Contrast-Enhanced Fluid-Attenuated Inversion Recovery, Magnetization Transfer Spin Echo, and Fat-Saturation T1-Weighted Sequences in Infectious Meningitis
title_short Qualitative and Quantitative Comparison of Contrast-Enhanced Fluid-Attenuated Inversion Recovery, Magnetization Transfer Spin Echo, and Fat-Saturation T1-Weighted Sequences in Infectious Meningitis
title_sort qualitative and quantitative comparison of contrast-enhanced fluid-attenuated inversion recovery, magnetization transfer spin echo, and fat-saturation t1-weighted sequences in infectious meningitis
topic Neuroimaging and Head & Neck
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5639163/
https://www.ncbi.nlm.nih.gov/pubmed/29089830
http://dx.doi.org/10.3348/kjr.2017.18.6.973
work_keys_str_mv AT azadrajiv qualitativeandquantitativecomparisonofcontrastenhancedfluidattenuatedinversionrecoverymagnetizationtransferspinechoandfatsaturationt1weightedsequencesininfectiousmeningitis
AT tayalmohit qualitativeandquantitativecomparisonofcontrastenhancedfluidattenuatedinversionrecoverymagnetizationtransferspinechoandfatsaturationt1weightedsequencesininfectiousmeningitis
AT azadsheenam qualitativeandquantitativecomparisonofcontrastenhancedfluidattenuatedinversionrecoverymagnetizationtransferspinechoandfatsaturationt1weightedsequencesininfectiousmeningitis
AT sharmagarima qualitativeandquantitativecomparisonofcontrastenhancedfluidattenuatedinversionrecoverymagnetizationtransferspinechoandfatsaturationt1weightedsequencesininfectiousmeningitis
AT srivastavarajendrakumar qualitativeandquantitativecomparisonofcontrastenhancedfluidattenuatedinversionrecoverymagnetizationtransferspinechoandfatsaturationt1weightedsequencesininfectiousmeningitis