Cargando…

Changes in aortic pulse wave velocity of four thoracic aortic stent grafts in an ex vivo porcine model

OBJECTIVES: Thoracic endovascular aortic repair (TEVAR) has been shown to lead to increased aortic stiffness. The aim of this study was to investigate the effect of stent graft type and stent graft length on aortic stiffness in a controlled, experimental setting. METHODS: Twenty porcine thoracic aor...

Descripción completa

Detalles Bibliográficos
Autores principales: de Beaufort, Hector W. L., Coda, Margherita, Conti, Michele, van Bakel, Theodorus M. J., Nauta, Foeke J. H., Lanzarone, Ettore, Moll, Frans L., van Herwaarden, Joost A., Auricchio, Ferdinando, Trimarchi, Santi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5642022/
https://www.ncbi.nlm.nih.gov/pubmed/28982135
http://dx.doi.org/10.1371/journal.pone.0186080
_version_ 1783271301330239488
author de Beaufort, Hector W. L.
Coda, Margherita
Conti, Michele
van Bakel, Theodorus M. J.
Nauta, Foeke J. H.
Lanzarone, Ettore
Moll, Frans L.
van Herwaarden, Joost A.
Auricchio, Ferdinando
Trimarchi, Santi
author_facet de Beaufort, Hector W. L.
Coda, Margherita
Conti, Michele
van Bakel, Theodorus M. J.
Nauta, Foeke J. H.
Lanzarone, Ettore
Moll, Frans L.
van Herwaarden, Joost A.
Auricchio, Ferdinando
Trimarchi, Santi
author_sort de Beaufort, Hector W. L.
collection PubMed
description OBJECTIVES: Thoracic endovascular aortic repair (TEVAR) has been shown to lead to increased aortic stiffness. The aim of this study was to investigate the effect of stent graft type and stent graft length on aortic stiffness in a controlled, experimental setting. METHODS: Twenty porcine thoracic aortas were connected to a pulsatile mock loop system. Intraluminal pressure was recorded at two sites in order to measure pulse wave velocity (PWV) for each aorta: before stent graft deployment (t(1)); after deployment of a 100-mm long stent graft (t(2)); and after distal extension through deployment of a second 100-mm long stent graft (t(3)). Four different types of stent grafts (Conformable Gore(®) TAG(®) Device, Bolton Relay(®) Device, Cook Zenith Alpha(™), and Medtronic Valiant(®)) were evaluated. RESULTS: For the total cohort of 20 aortas, PWV increased by a mean 0.6 m/s or 8.9% of baseline PWV after deployment of a 100-mm proximal stent graft (P<0.001), and by a mean 1.4 m/s or 23.0% of baseline PWV after distal extension of the stent graft (P<0.001). Univariable regression analysis showed a significant correlation between aortic PWV and extent of stent graft coverage, (P<0.001), but no significant effect of baseline aortic length, baseline aortic PWV, or stent graft type on the percentual increase in PWV at t(2) or at t(3). CONCLUSIONS: In this experimental set-up, aortic stiffness increased significantly after stent graft deployment with each of the four types of stent graft, with the increase in aortic stiffness depending on the extent of stent graft coverage.
format Online
Article
Text
id pubmed-5642022
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-56420222017-10-30 Changes in aortic pulse wave velocity of four thoracic aortic stent grafts in an ex vivo porcine model de Beaufort, Hector W. L. Coda, Margherita Conti, Michele van Bakel, Theodorus M. J. Nauta, Foeke J. H. Lanzarone, Ettore Moll, Frans L. van Herwaarden, Joost A. Auricchio, Ferdinando Trimarchi, Santi PLoS One Research Article OBJECTIVES: Thoracic endovascular aortic repair (TEVAR) has been shown to lead to increased aortic stiffness. The aim of this study was to investigate the effect of stent graft type and stent graft length on aortic stiffness in a controlled, experimental setting. METHODS: Twenty porcine thoracic aortas were connected to a pulsatile mock loop system. Intraluminal pressure was recorded at two sites in order to measure pulse wave velocity (PWV) for each aorta: before stent graft deployment (t(1)); after deployment of a 100-mm long stent graft (t(2)); and after distal extension through deployment of a second 100-mm long stent graft (t(3)). Four different types of stent grafts (Conformable Gore(®) TAG(®) Device, Bolton Relay(®) Device, Cook Zenith Alpha(™), and Medtronic Valiant(®)) were evaluated. RESULTS: For the total cohort of 20 aortas, PWV increased by a mean 0.6 m/s or 8.9% of baseline PWV after deployment of a 100-mm proximal stent graft (P<0.001), and by a mean 1.4 m/s or 23.0% of baseline PWV after distal extension of the stent graft (P<0.001). Univariable regression analysis showed a significant correlation between aortic PWV and extent of stent graft coverage, (P<0.001), but no significant effect of baseline aortic length, baseline aortic PWV, or stent graft type on the percentual increase in PWV at t(2) or at t(3). CONCLUSIONS: In this experimental set-up, aortic stiffness increased significantly after stent graft deployment with each of the four types of stent graft, with the increase in aortic stiffness depending on the extent of stent graft coverage. Public Library of Science 2017-10-05 /pmc/articles/PMC5642022/ /pubmed/28982135 http://dx.doi.org/10.1371/journal.pone.0186080 Text en © 2017 de Beaufort et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
de Beaufort, Hector W. L.
Coda, Margherita
Conti, Michele
van Bakel, Theodorus M. J.
Nauta, Foeke J. H.
Lanzarone, Ettore
Moll, Frans L.
van Herwaarden, Joost A.
Auricchio, Ferdinando
Trimarchi, Santi
Changes in aortic pulse wave velocity of four thoracic aortic stent grafts in an ex vivo porcine model
title Changes in aortic pulse wave velocity of four thoracic aortic stent grafts in an ex vivo porcine model
title_full Changes in aortic pulse wave velocity of four thoracic aortic stent grafts in an ex vivo porcine model
title_fullStr Changes in aortic pulse wave velocity of four thoracic aortic stent grafts in an ex vivo porcine model
title_full_unstemmed Changes in aortic pulse wave velocity of four thoracic aortic stent grafts in an ex vivo porcine model
title_short Changes in aortic pulse wave velocity of four thoracic aortic stent grafts in an ex vivo porcine model
title_sort changes in aortic pulse wave velocity of four thoracic aortic stent grafts in an ex vivo porcine model
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5642022/
https://www.ncbi.nlm.nih.gov/pubmed/28982135
http://dx.doi.org/10.1371/journal.pone.0186080
work_keys_str_mv AT debeauforthectorwl changesinaorticpulsewavevelocityoffourthoracicaorticstentgraftsinanexvivoporcinemodel
AT codamargherita changesinaorticpulsewavevelocityoffourthoracicaorticstentgraftsinanexvivoporcinemodel
AT contimichele changesinaorticpulsewavevelocityoffourthoracicaorticstentgraftsinanexvivoporcinemodel
AT vanbakeltheodorusmj changesinaorticpulsewavevelocityoffourthoracicaorticstentgraftsinanexvivoporcinemodel
AT nautafoekejh changesinaorticpulsewavevelocityoffourthoracicaorticstentgraftsinanexvivoporcinemodel
AT lanzaroneettore changesinaorticpulsewavevelocityoffourthoracicaorticstentgraftsinanexvivoporcinemodel
AT mollfransl changesinaorticpulsewavevelocityoffourthoracicaorticstentgraftsinanexvivoporcinemodel
AT vanherwaardenjoosta changesinaorticpulsewavevelocityoffourthoracicaorticstentgraftsinanexvivoporcinemodel
AT auricchioferdinando changesinaorticpulsewavevelocityoffourthoracicaorticstentgraftsinanexvivoporcinemodel
AT trimarchisanti changesinaorticpulsewavevelocityoffourthoracicaorticstentgraftsinanexvivoporcinemodel