Cargando…

Development of breath test for pneumoconiosis: a case-control study

BACKGROUND: Lipid peroxidation plays an important role in the pathogenesis of pneumoconiosis. Volatile organic compounds (VOCs) generated from lipid peroxidation might be used to detect pneumoconiosis. The objective of this study was to develop a breath test for pneumoconiosis. METHODS: A case-contr...

Descripción completa

Detalles Bibliográficos
Autores principales: Yang, Hsiao-Yu, Shie, Ruei-Hao, Chang, Che-Jui, Chen, Pau-Chung
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5645979/
https://www.ncbi.nlm.nih.gov/pubmed/29041938
http://dx.doi.org/10.1186/s12931-017-0661-3
_version_ 1783271995139424256
author Yang, Hsiao-Yu
Shie, Ruei-Hao
Chang, Che-Jui
Chen, Pau-Chung
author_facet Yang, Hsiao-Yu
Shie, Ruei-Hao
Chang, Che-Jui
Chen, Pau-Chung
author_sort Yang, Hsiao-Yu
collection PubMed
description BACKGROUND: Lipid peroxidation plays an important role in the pathogenesis of pneumoconiosis. Volatile organic compounds (VOCs) generated from lipid peroxidation might be used to detect pneumoconiosis. The objective of this study was to develop a breath test for pneumoconiosis. METHODS: A case-control study was designed. Breath and ambient air were analysed by gas chromatography/mass spectrometry. After blank correction to prevent contamination from ambient air, we used canonical discriminant analysis (CDA) to assess the discrimination accuracy and principal component analysis (PCA) to generate a prediction score. The prediction accuracy was calculated and validated using the International Classification of Radiographs of the Pneumoconiosis criteria combined with an abnormal pulmonary function test as a reference standard. We generated a receiver operator characteristic (ROC) curve and calculated the area under the ROC curve (AUC) to estimate the screening accuracy of the breath test. RESULTS: We enrolled 200 stone workers. After excluding 5 subjects with asthma and 16 subjects who took steroids or nonsteroidal anti-inflammatory drugs, a total of 179 subjects were used in the final analyses, which included 25 cases and 154 controls. By CDA, 88.8% of subjects were correctly discriminated by their exposure status and the presence of pneumoconiosis. After excluding the VOCs of automobile exhaust and cigarette smoking, pentane and C5-C7 methylated alkanes constituted the major VOCs in the breath of persons with pneumoconiosis. Using the prediction score generated from PCA, the ROC-AUC was 0.88 (95% CI = 0.80—0.95), and the mean ROC-AUC of 5-fold cross-validation was 0.90. The breath test had good accuracy for pneumoconiosis diagnosis. CONCLUSION: The analysis of breath VOCs has potential in the screening of pneumoconiosis for its non-invasiveness and high accuracy. We suggest that a multi-centre study is warranted and that all procedures must be standardized before clinical application.
format Online
Article
Text
id pubmed-5645979
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-56459792017-10-26 Development of breath test for pneumoconiosis: a case-control study Yang, Hsiao-Yu Shie, Ruei-Hao Chang, Che-Jui Chen, Pau-Chung Respir Res Research BACKGROUND: Lipid peroxidation plays an important role in the pathogenesis of pneumoconiosis. Volatile organic compounds (VOCs) generated from lipid peroxidation might be used to detect pneumoconiosis. The objective of this study was to develop a breath test for pneumoconiosis. METHODS: A case-control study was designed. Breath and ambient air were analysed by gas chromatography/mass spectrometry. After blank correction to prevent contamination from ambient air, we used canonical discriminant analysis (CDA) to assess the discrimination accuracy and principal component analysis (PCA) to generate a prediction score. The prediction accuracy was calculated and validated using the International Classification of Radiographs of the Pneumoconiosis criteria combined with an abnormal pulmonary function test as a reference standard. We generated a receiver operator characteristic (ROC) curve and calculated the area under the ROC curve (AUC) to estimate the screening accuracy of the breath test. RESULTS: We enrolled 200 stone workers. After excluding 5 subjects with asthma and 16 subjects who took steroids or nonsteroidal anti-inflammatory drugs, a total of 179 subjects were used in the final analyses, which included 25 cases and 154 controls. By CDA, 88.8% of subjects were correctly discriminated by their exposure status and the presence of pneumoconiosis. After excluding the VOCs of automobile exhaust and cigarette smoking, pentane and C5-C7 methylated alkanes constituted the major VOCs in the breath of persons with pneumoconiosis. Using the prediction score generated from PCA, the ROC-AUC was 0.88 (95% CI = 0.80—0.95), and the mean ROC-AUC of 5-fold cross-validation was 0.90. The breath test had good accuracy for pneumoconiosis diagnosis. CONCLUSION: The analysis of breath VOCs has potential in the screening of pneumoconiosis for its non-invasiveness and high accuracy. We suggest that a multi-centre study is warranted and that all procedures must be standardized before clinical application. BioMed Central 2017-10-17 2017 /pmc/articles/PMC5645979/ /pubmed/29041938 http://dx.doi.org/10.1186/s12931-017-0661-3 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Yang, Hsiao-Yu
Shie, Ruei-Hao
Chang, Che-Jui
Chen, Pau-Chung
Development of breath test for pneumoconiosis: a case-control study
title Development of breath test for pneumoconiosis: a case-control study
title_full Development of breath test for pneumoconiosis: a case-control study
title_fullStr Development of breath test for pneumoconiosis: a case-control study
title_full_unstemmed Development of breath test for pneumoconiosis: a case-control study
title_short Development of breath test for pneumoconiosis: a case-control study
title_sort development of breath test for pneumoconiosis: a case-control study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5645979/
https://www.ncbi.nlm.nih.gov/pubmed/29041938
http://dx.doi.org/10.1186/s12931-017-0661-3
work_keys_str_mv AT yanghsiaoyu developmentofbreathtestforpneumoconiosisacasecontrolstudy
AT shierueihao developmentofbreathtestforpneumoconiosisacasecontrolstudy
AT changchejui developmentofbreathtestforpneumoconiosisacasecontrolstudy
AT chenpauchung developmentofbreathtestforpneumoconiosisacasecontrolstudy