Intrasession repeatability of ocular anatomical measurements obtained with a multidiagnostic device in healthy eyes

BACKGROUND: To evaluate the intrasession repeatability of anterior chamber depth (ACD), central (CCT) and peripheral corneal thickness (PCT), white-to-white diameter (WTW), and irido-corneal angle (IA) measurements obtained with a multidiagnostic device in healthy eyes. METHODS: A total of 107 eyes...

Descripción completa

Detalles Bibliográficos
Autores principales: Piñero, David P., Cabezos, Inmaculada, López-Navarro, Alberto, de Fez, Dolores, Caballero, María T., Camps, Vicente J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5648429/
https://www.ncbi.nlm.nih.gov/pubmed/29047369
http://dx.doi.org/10.1186/s12886-017-0589-x
_version_ 1783272392046411776
author Piñero, David P.
Cabezos, Inmaculada
López-Navarro, Alberto
de Fez, Dolores
Caballero, María T.
Camps, Vicente J.
author_facet Piñero, David P.
Cabezos, Inmaculada
López-Navarro, Alberto
de Fez, Dolores
Caballero, María T.
Camps, Vicente J.
author_sort Piñero, David P.
collection PubMed
description BACKGROUND: To evaluate the intrasession repeatability of anterior chamber depth (ACD), central (CCT) and peripheral corneal thickness (PCT), white-to-white diameter (WTW), and irido-corneal angle (IA) measurements obtained with a multidiagnostic device in healthy eyes. METHODS: A total of 107 eyes of 107 patients ranging in age from 23 to 65 years were examined with the VX120 system (Visionix-Luneau Technologies). Three consecutive measurements were obtained with this device to assess the intrasession repeatability of ACD, CCT, PCT at different nasal and temporal locations, WTW, and nasal and temporal IA. Data analysis included the calculation of within-subject standard deviation (S(w)), intrasubject precision (1.96xS(w)), coefficient of variation (CV) and intraclass correlation coefficient (ICC). RESULTS: The S(w) and CV for ACD was 0.03 mm and 1.16%, respectively, with an ICC of 0.992. The S(w) values for central and peripheral pachymetric measurements were below 9 μm, with CV of less than 1.6% and ICC of 0.976 or higher. For IA measurements, S(w) values of 0.84 or lower were found, with a CV between 1 and 2%, and an ICC of more than 0.970. The S(w) for WTW was 0.24 mm and the CV was 1.95%. No statistically significant correlations were found between any anatomical parameter evaluated and their S(w) and CV values associated (−0.220 ≤ r ≤ 0.204, p ≥ 0.125). CONCLUSIONS: The VX120 system is able to provide repeatable measurements of anatomical parameters in healthy eyes. Inter-observer repeatability should be evaluated in future studies.
format Online
Article
Text
id pubmed-5648429
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-56484292017-10-26 Intrasession repeatability of ocular anatomical measurements obtained with a multidiagnostic device in healthy eyes Piñero, David P. Cabezos, Inmaculada López-Navarro, Alberto de Fez, Dolores Caballero, María T. Camps, Vicente J. BMC Ophthalmol Research Article BACKGROUND: To evaluate the intrasession repeatability of anterior chamber depth (ACD), central (CCT) and peripheral corneal thickness (PCT), white-to-white diameter (WTW), and irido-corneal angle (IA) measurements obtained with a multidiagnostic device in healthy eyes. METHODS: A total of 107 eyes of 107 patients ranging in age from 23 to 65 years were examined with the VX120 system (Visionix-Luneau Technologies). Three consecutive measurements were obtained with this device to assess the intrasession repeatability of ACD, CCT, PCT at different nasal and temporal locations, WTW, and nasal and temporal IA. Data analysis included the calculation of within-subject standard deviation (S(w)), intrasubject precision (1.96xS(w)), coefficient of variation (CV) and intraclass correlation coefficient (ICC). RESULTS: The S(w) and CV for ACD was 0.03 mm and 1.16%, respectively, with an ICC of 0.992. The S(w) values for central and peripheral pachymetric measurements were below 9 μm, with CV of less than 1.6% and ICC of 0.976 or higher. For IA measurements, S(w) values of 0.84 or lower were found, with a CV between 1 and 2%, and an ICC of more than 0.970. The S(w) for WTW was 0.24 mm and the CV was 1.95%. No statistically significant correlations were found between any anatomical parameter evaluated and their S(w) and CV values associated (−0.220 ≤ r ≤ 0.204, p ≥ 0.125). CONCLUSIONS: The VX120 system is able to provide repeatable measurements of anatomical parameters in healthy eyes. Inter-observer repeatability should be evaluated in future studies. BioMed Central 2017-10-18 /pmc/articles/PMC5648429/ /pubmed/29047369 http://dx.doi.org/10.1186/s12886-017-0589-x Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Piñero, David P.
Cabezos, Inmaculada
López-Navarro, Alberto
de Fez, Dolores
Caballero, María T.
Camps, Vicente J.
Intrasession repeatability of ocular anatomical measurements obtained with a multidiagnostic device in healthy eyes
title Intrasession repeatability of ocular anatomical measurements obtained with a multidiagnostic device in healthy eyes
title_full Intrasession repeatability of ocular anatomical measurements obtained with a multidiagnostic device in healthy eyes
title_fullStr Intrasession repeatability of ocular anatomical measurements obtained with a multidiagnostic device in healthy eyes
title_full_unstemmed Intrasession repeatability of ocular anatomical measurements obtained with a multidiagnostic device in healthy eyes
title_short Intrasession repeatability of ocular anatomical measurements obtained with a multidiagnostic device in healthy eyes
title_sort intrasession repeatability of ocular anatomical measurements obtained with a multidiagnostic device in healthy eyes
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5648429/
https://www.ncbi.nlm.nih.gov/pubmed/29047369
http://dx.doi.org/10.1186/s12886-017-0589-x
work_keys_str_mv AT pinerodavidp intrasessionrepeatabilityofocularanatomicalmeasurementsobtainedwithamultidiagnosticdeviceinhealthyeyes
AT cabezosinmaculada intrasessionrepeatabilityofocularanatomicalmeasurementsobtainedwithamultidiagnosticdeviceinhealthyeyes
AT lopeznavarroalberto intrasessionrepeatabilityofocularanatomicalmeasurementsobtainedwithamultidiagnosticdeviceinhealthyeyes
AT defezdolores intrasessionrepeatabilityofocularanatomicalmeasurementsobtainedwithamultidiagnosticdeviceinhealthyeyes
AT caballeromariat intrasessionrepeatabilityofocularanatomicalmeasurementsobtainedwithamultidiagnosticdeviceinhealthyeyes
AT campsvicentej intrasessionrepeatabilityofocularanatomicalmeasurementsobtainedwithamultidiagnosticdeviceinhealthyeyes