Fully quantitative cardiovascular magnetic resonance myocardial perfusion ready for clinical use: a comparison between cardiovascular magnetic resonance imaging and positron emission tomography

BACKGROUND: Recent studies have shown that quantification of myocardial perfusion (MP) at stress and myocardial perfusion reserve (MPR) offer additional diagnostic and prognostic information compared to qualitative and semi-quantitative assessment of myocardial perfusion distribution in patients wit...

Descripción completa

Detalles Bibliográficos
Autores principales: Engblom, Henrik, Xue, Hui, Akil, Shahnaz, Carlsson, Marcus, Hindorf, Cecilia, Oddstig, Jenny, Hedeer, Fredrik, Hansen, Michael S., Aletras, Anthony H., Kellman, Peter, Arheden, Håkan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5648469/
https://www.ncbi.nlm.nih.gov/pubmed/29047385
http://dx.doi.org/10.1186/s12968-017-0388-9
_version_ 1783272401498275840
author Engblom, Henrik
Xue, Hui
Akil, Shahnaz
Carlsson, Marcus
Hindorf, Cecilia
Oddstig, Jenny
Hedeer, Fredrik
Hansen, Michael S.
Aletras, Anthony H.
Kellman, Peter
Arheden, Håkan
author_facet Engblom, Henrik
Xue, Hui
Akil, Shahnaz
Carlsson, Marcus
Hindorf, Cecilia
Oddstig, Jenny
Hedeer, Fredrik
Hansen, Michael S.
Aletras, Anthony H.
Kellman, Peter
Arheden, Håkan
author_sort Engblom, Henrik
collection PubMed
description BACKGROUND: Recent studies have shown that quantification of myocardial perfusion (MP) at stress and myocardial perfusion reserve (MPR) offer additional diagnostic and prognostic information compared to qualitative and semi-quantitative assessment of myocardial perfusion distribution in patients with coronary artery disease (CAD). Technical advancements have enabled fully automatic quantification of MP using cardiovascular magnetic resonance (CMR) to be performed in-line in a clinical workflow. The aim of this study was to validate the use of the automated CMR perfusion mapping technique for quantification of MP using 13N–NH3 cardiac positron emission tomography (PET) as the reference method. METHODS: Twenty-one patients with stable CAD were included in the study. All patients underwent adenosine stress and rest perfusion imaging with 13N–NH3 PET and a dual sequence, single contrast bolus CMR on the same day. Global and regional MP were quantified both at stress and rest using PET and CMR. RESULTS: There was good agreement between global MP quantified by PET and CMR both at stress (−0.1 ± 0.5 ml/min/g) and at rest (0 ± 0.2 ml/min/g) with a strong correlation (r = 0.92, p < 0.001; y = 0.94× + 0.14). Furthermore, there was strong correlation between CMR and PET with regards to regional MP (r = 0.83, p < 0.001; y = 0.87× + 0.26) with a good agreement (−0.1 ± 0.6 ml/min/g). There was also a significant correlation between CMR and PET with regard to global and regional MPR (r = 0.69, p = 0.001 and r = 0.57, p < 0.001, respectively). CONCLUSIONS: There is good agreement between MP quantified by 13N–NH3 PET and dual sequence, single contrast bolus CMR in patients with stable CAD. Thus, CMR is viable in clinical practice for quantification of MP.
format Online
Article
Text
id pubmed-5648469
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-56484692017-10-26 Fully quantitative cardiovascular magnetic resonance myocardial perfusion ready for clinical use: a comparison between cardiovascular magnetic resonance imaging and positron emission tomography Engblom, Henrik Xue, Hui Akil, Shahnaz Carlsson, Marcus Hindorf, Cecilia Oddstig, Jenny Hedeer, Fredrik Hansen, Michael S. Aletras, Anthony H. Kellman, Peter Arheden, Håkan J Cardiovasc Magn Reson Research BACKGROUND: Recent studies have shown that quantification of myocardial perfusion (MP) at stress and myocardial perfusion reserve (MPR) offer additional diagnostic and prognostic information compared to qualitative and semi-quantitative assessment of myocardial perfusion distribution in patients with coronary artery disease (CAD). Technical advancements have enabled fully automatic quantification of MP using cardiovascular magnetic resonance (CMR) to be performed in-line in a clinical workflow. The aim of this study was to validate the use of the automated CMR perfusion mapping technique for quantification of MP using 13N–NH3 cardiac positron emission tomography (PET) as the reference method. METHODS: Twenty-one patients with stable CAD were included in the study. All patients underwent adenosine stress and rest perfusion imaging with 13N–NH3 PET and a dual sequence, single contrast bolus CMR on the same day. Global and regional MP were quantified both at stress and rest using PET and CMR. RESULTS: There was good agreement between global MP quantified by PET and CMR both at stress (−0.1 ± 0.5 ml/min/g) and at rest (0 ± 0.2 ml/min/g) with a strong correlation (r = 0.92, p < 0.001; y = 0.94× + 0.14). Furthermore, there was strong correlation between CMR and PET with regards to regional MP (r = 0.83, p < 0.001; y = 0.87× + 0.26) with a good agreement (−0.1 ± 0.6 ml/min/g). There was also a significant correlation between CMR and PET with regard to global and regional MPR (r = 0.69, p = 0.001 and r = 0.57, p < 0.001, respectively). CONCLUSIONS: There is good agreement between MP quantified by 13N–NH3 PET and dual sequence, single contrast bolus CMR in patients with stable CAD. Thus, CMR is viable in clinical practice for quantification of MP. BioMed Central 2017-10-19 /pmc/articles/PMC5648469/ /pubmed/29047385 http://dx.doi.org/10.1186/s12968-017-0388-9 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Engblom, Henrik
Xue, Hui
Akil, Shahnaz
Carlsson, Marcus
Hindorf, Cecilia
Oddstig, Jenny
Hedeer, Fredrik
Hansen, Michael S.
Aletras, Anthony H.
Kellman, Peter
Arheden, Håkan
Fully quantitative cardiovascular magnetic resonance myocardial perfusion ready for clinical use: a comparison between cardiovascular magnetic resonance imaging and positron emission tomography
title Fully quantitative cardiovascular magnetic resonance myocardial perfusion ready for clinical use: a comparison between cardiovascular magnetic resonance imaging and positron emission tomography
title_full Fully quantitative cardiovascular magnetic resonance myocardial perfusion ready for clinical use: a comparison between cardiovascular magnetic resonance imaging and positron emission tomography
title_fullStr Fully quantitative cardiovascular magnetic resonance myocardial perfusion ready for clinical use: a comparison between cardiovascular magnetic resonance imaging and positron emission tomography
title_full_unstemmed Fully quantitative cardiovascular magnetic resonance myocardial perfusion ready for clinical use: a comparison between cardiovascular magnetic resonance imaging and positron emission tomography
title_short Fully quantitative cardiovascular magnetic resonance myocardial perfusion ready for clinical use: a comparison between cardiovascular magnetic resonance imaging and positron emission tomography
title_sort fully quantitative cardiovascular magnetic resonance myocardial perfusion ready for clinical use: a comparison between cardiovascular magnetic resonance imaging and positron emission tomography
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5648469/
https://www.ncbi.nlm.nih.gov/pubmed/29047385
http://dx.doi.org/10.1186/s12968-017-0388-9
work_keys_str_mv AT engblomhenrik fullyquantitativecardiovascularmagneticresonancemyocardialperfusionreadyforclinicaluseacomparisonbetweencardiovascularmagneticresonanceimagingandpositronemissiontomography
AT xuehui fullyquantitativecardiovascularmagneticresonancemyocardialperfusionreadyforclinicaluseacomparisonbetweencardiovascularmagneticresonanceimagingandpositronemissiontomography
AT akilshahnaz fullyquantitativecardiovascularmagneticresonancemyocardialperfusionreadyforclinicaluseacomparisonbetweencardiovascularmagneticresonanceimagingandpositronemissiontomography
AT carlssonmarcus fullyquantitativecardiovascularmagneticresonancemyocardialperfusionreadyforclinicaluseacomparisonbetweencardiovascularmagneticresonanceimagingandpositronemissiontomography
AT hindorfcecilia fullyquantitativecardiovascularmagneticresonancemyocardialperfusionreadyforclinicaluseacomparisonbetweencardiovascularmagneticresonanceimagingandpositronemissiontomography
AT oddstigjenny fullyquantitativecardiovascularmagneticresonancemyocardialperfusionreadyforclinicaluseacomparisonbetweencardiovascularmagneticresonanceimagingandpositronemissiontomography
AT hedeerfredrik fullyquantitativecardiovascularmagneticresonancemyocardialperfusionreadyforclinicaluseacomparisonbetweencardiovascularmagneticresonanceimagingandpositronemissiontomography
AT hansenmichaels fullyquantitativecardiovascularmagneticresonancemyocardialperfusionreadyforclinicaluseacomparisonbetweencardiovascularmagneticresonanceimagingandpositronemissiontomography
AT aletrasanthonyh fullyquantitativecardiovascularmagneticresonancemyocardialperfusionreadyforclinicaluseacomparisonbetweencardiovascularmagneticresonanceimagingandpositronemissiontomography
AT kellmanpeter fullyquantitativecardiovascularmagneticresonancemyocardialperfusionreadyforclinicaluseacomparisonbetweencardiovascularmagneticresonanceimagingandpositronemissiontomography
AT arhedenhakan fullyquantitativecardiovascularmagneticresonancemyocardialperfusionreadyforclinicaluseacomparisonbetweencardiovascularmagneticresonanceimagingandpositronemissiontomography