Key results from the first plasma operation phase and outlook for future performance in Wendelstein 7-X
The first physics operation phase on the stellarator experiment Wendelstein 7-X was successfully completed in March 2016 after about 10 weeks of operation. Experiments in this phase were conducted with five graphite limiters as the primary plasma-facing components. Overall, the results were beyond t...
Autores principales: | , , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
AIP Publishing LLC
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5648559/ https://www.ncbi.nlm.nih.gov/pubmed/29104420 http://dx.doi.org/10.1063/1.4983629 |
_version_ | 1783272415912001536 |
---|---|
author | Sunn Pedersen, Thomas Dinklage, Andreas Turkin, Yuriy Wolf, Robert Bozhenkov, Sergey Geiger, Joachim Fuchert, Golo Bosch, Hans-Stephan Rahbarnia, Kian Thomsen, Henning Neuner, Ulrich Klinger, Thomas Langenberg, Andreas Trimiño Mora, Humberto Kornejew, Petra Knauer, Jens Hirsch, Matthias Pablant, Novimir |
author_facet | Sunn Pedersen, Thomas Dinklage, Andreas Turkin, Yuriy Wolf, Robert Bozhenkov, Sergey Geiger, Joachim Fuchert, Golo Bosch, Hans-Stephan Rahbarnia, Kian Thomsen, Henning Neuner, Ulrich Klinger, Thomas Langenberg, Andreas Trimiño Mora, Humberto Kornejew, Petra Knauer, Jens Hirsch, Matthias Pablant, Novimir |
author_sort | Sunn Pedersen, Thomas |
collection | PubMed |
description | The first physics operation phase on the stellarator experiment Wendelstein 7-X was successfully completed in March 2016 after about 10 weeks of operation. Experiments in this phase were conducted with five graphite limiters as the primary plasma-facing components. Overall, the results were beyond the expectations published shortly before the start of operation [Sunn Pedersen et al., Nucl. Fusion 55, 126001 (2015)] both with respect to parameters reached and with respect to physics themes addressed. We report here on some of the most important plasma experiments that were conducted. The importance of electric fields on global confinement will be discussed, and the obtained results will be compared and contrasted with results from other devices, quantified in terms of the fusion triple product. Expected values for the triple product in future operation phases will also be described and put into a broader fusion perspective. |
format | Online Article Text |
id | pubmed-5648559 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | AIP Publishing LLC |
record_format | MEDLINE/PubMed |
spelling | pubmed-56485592017-11-04 Key results from the first plasma operation phase and outlook for future performance in Wendelstein 7-X Sunn Pedersen, Thomas Dinklage, Andreas Turkin, Yuriy Wolf, Robert Bozhenkov, Sergey Geiger, Joachim Fuchert, Golo Bosch, Hans-Stephan Rahbarnia, Kian Thomsen, Henning Neuner, Ulrich Klinger, Thomas Langenberg, Andreas Trimiño Mora, Humberto Kornejew, Petra Knauer, Jens Hirsch, Matthias Pablant, Novimir Phys Plasmas Review Papers The first physics operation phase on the stellarator experiment Wendelstein 7-X was successfully completed in March 2016 after about 10 weeks of operation. Experiments in this phase were conducted with five graphite limiters as the primary plasma-facing components. Overall, the results were beyond the expectations published shortly before the start of operation [Sunn Pedersen et al., Nucl. Fusion 55, 126001 (2015)] both with respect to parameters reached and with respect to physics themes addressed. We report here on some of the most important plasma experiments that were conducted. The importance of electric fields on global confinement will be discussed, and the obtained results will be compared and contrasted with results from other devices, quantified in terms of the fusion triple product. Expected values for the triple product in future operation phases will also be described and put into a broader fusion perspective. AIP Publishing LLC 2017-05 2017-05-18 /pmc/articles/PMC5648559/ /pubmed/29104420 http://dx.doi.org/10.1063/1.4983629 Text en © 2017 Author(s). 1070-664X/2017/24(5)/055503/10 All article content, except where otherwise noted, is licensed under a Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Review Papers Sunn Pedersen, Thomas Dinklage, Andreas Turkin, Yuriy Wolf, Robert Bozhenkov, Sergey Geiger, Joachim Fuchert, Golo Bosch, Hans-Stephan Rahbarnia, Kian Thomsen, Henning Neuner, Ulrich Klinger, Thomas Langenberg, Andreas Trimiño Mora, Humberto Kornejew, Petra Knauer, Jens Hirsch, Matthias Pablant, Novimir Key results from the first plasma operation phase and outlook for future performance in Wendelstein 7-X |
title | Key results from the first plasma operation phase and outlook for future
performance in Wendelstein 7-X |
title_full | Key results from the first plasma operation phase and outlook for future
performance in Wendelstein 7-X |
title_fullStr | Key results from the first plasma operation phase and outlook for future
performance in Wendelstein 7-X |
title_full_unstemmed | Key results from the first plasma operation phase and outlook for future
performance in Wendelstein 7-X |
title_short | Key results from the first plasma operation phase and outlook for future
performance in Wendelstein 7-X |
title_sort | key results from the first plasma operation phase and outlook for future
performance in wendelstein 7-x |
topic | Review Papers |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5648559/ https://www.ncbi.nlm.nih.gov/pubmed/29104420 http://dx.doi.org/10.1063/1.4983629 |
work_keys_str_mv | AT sunnpedersenthomas keyresultsfromthefirstplasmaoperationphaseandoutlookforfutureperformanceinwendelstein7x AT dinklageandreas keyresultsfromthefirstplasmaoperationphaseandoutlookforfutureperformanceinwendelstein7x AT turkinyuriy keyresultsfromthefirstplasmaoperationphaseandoutlookforfutureperformanceinwendelstein7x AT wolfrobert keyresultsfromthefirstplasmaoperationphaseandoutlookforfutureperformanceinwendelstein7x AT bozhenkovsergey keyresultsfromthefirstplasmaoperationphaseandoutlookforfutureperformanceinwendelstein7x AT geigerjoachim keyresultsfromthefirstplasmaoperationphaseandoutlookforfutureperformanceinwendelstein7x AT fuchertgolo keyresultsfromthefirstplasmaoperationphaseandoutlookforfutureperformanceinwendelstein7x AT boschhansstephan keyresultsfromthefirstplasmaoperationphaseandoutlookforfutureperformanceinwendelstein7x AT rahbarniakian keyresultsfromthefirstplasmaoperationphaseandoutlookforfutureperformanceinwendelstein7x AT thomsenhenning keyresultsfromthefirstplasmaoperationphaseandoutlookforfutureperformanceinwendelstein7x AT neunerulrich keyresultsfromthefirstplasmaoperationphaseandoutlookforfutureperformanceinwendelstein7x AT klingerthomas keyresultsfromthefirstplasmaoperationphaseandoutlookforfutureperformanceinwendelstein7x AT langenbergandreas keyresultsfromthefirstplasmaoperationphaseandoutlookforfutureperformanceinwendelstein7x AT triminomorahumberto keyresultsfromthefirstplasmaoperationphaseandoutlookforfutureperformanceinwendelstein7x AT kornejewpetra keyresultsfromthefirstplasmaoperationphaseandoutlookforfutureperformanceinwendelstein7x AT knauerjens keyresultsfromthefirstplasmaoperationphaseandoutlookforfutureperformanceinwendelstein7x AT hirschmatthias keyresultsfromthefirstplasmaoperationphaseandoutlookforfutureperformanceinwendelstein7x AT keyresultsfromthefirstplasmaoperationphaseandoutlookforfutureperformanceinwendelstein7x AT pablantnovimir keyresultsfromthefirstplasmaoperationphaseandoutlookforfutureperformanceinwendelstein7x |