Cargando…
Meta-Analysis of Comparative Trials Evaluating a Prophylactic Single-Use Negative Pressure Wound Therapy System for the Prevention of Surgical Site Complications
Background: We report the first meta-analysis on the impact of prophylactic use of a specific design of negative pressure wound therapy (NPWT) device on surgical site complications. Methods: Articles were identified in which the specific single-use NPWT device (PICO(⋄), Smith & Nephew) was compa...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Mary Ann Liebert, Inc.
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5649123/ https://www.ncbi.nlm.nih.gov/pubmed/28885895 http://dx.doi.org/10.1089/sur.2017.156 |
_version_ | 1783272503680958464 |
---|---|
author | Strugala, Vicki Martin, Robin |
author_facet | Strugala, Vicki Martin, Robin |
author_sort | Strugala, Vicki |
collection | PubMed |
description | Background: We report the first meta-analysis on the impact of prophylactic use of a specific design of negative pressure wound therapy (NPWT) device on surgical site complications. Methods: Articles were identified in which the specific single-use NPWT device (PICO(⋄), Smith & Nephew) was compared with standard care for surgical site infection (SSI), dehiscence, or length of stay (LOS). Risk ratio (RR) ±95% confidence interval (CI) (SSI; dehiscence) or mean difference in LOS ±95% CI was calculated using RevMan v5.3. Results: There were 1863 patients (2202 incisions) represented by 16 articles. Among 10 randomized studies, there was a significant reduction in SSI rate of 51% from 9.7% to 4.8% with NPWT intervention (RR 0.49 [95% CI 0.34–0.69] p < 0.0001). There were six observational studies assessing reduction in SSI rate of 67% from 22.5% to 7.4% with NPWT (RR 0. 32 [95% CI 0.18–0.55] p < 0.0001). Combining all 16 studies, there was a significant reduction in SSI of 58% from 12.5% to 5.2% with NPWT (RR 0.43 [95% CI 0.32–0.57] p < 0.0001). Similar effects were seen irrespective of the kind of surgery (orthopedic, abdominal, colorectal, or cesarean section), although the numbers needed to treat (NNT) were lower in operations with higher frequencies of complications. There was a significant reduction in dehiscence from 17.4% to 12.8% with NPWT (RR 0.71 [95% CI 0.54–0.92] p < 0.01). The mean reduction in hospital LOS by NPWT was also significant (−0.47 days [95% CI −0.71 to −0.23] p < 0.0001). Conclusions: The significant reduction in SSI, wound dehiscence, and LOS on the basis of pooled data from 16 studies shows a benefit of the PICO single-use NPWT system compared with standard care in closed surgical incisions. |
format | Online Article Text |
id | pubmed-5649123 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Mary Ann Liebert, Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-56491232017-10-23 Meta-Analysis of Comparative Trials Evaluating a Prophylactic Single-Use Negative Pressure Wound Therapy System for the Prevention of Surgical Site Complications Strugala, Vicki Martin, Robin Surg Infect (Larchmt) Original Articles Background: We report the first meta-analysis on the impact of prophylactic use of a specific design of negative pressure wound therapy (NPWT) device on surgical site complications. Methods: Articles were identified in which the specific single-use NPWT device (PICO(⋄), Smith & Nephew) was compared with standard care for surgical site infection (SSI), dehiscence, or length of stay (LOS). Risk ratio (RR) ±95% confidence interval (CI) (SSI; dehiscence) or mean difference in LOS ±95% CI was calculated using RevMan v5.3. Results: There were 1863 patients (2202 incisions) represented by 16 articles. Among 10 randomized studies, there was a significant reduction in SSI rate of 51% from 9.7% to 4.8% with NPWT intervention (RR 0.49 [95% CI 0.34–0.69] p < 0.0001). There were six observational studies assessing reduction in SSI rate of 67% from 22.5% to 7.4% with NPWT (RR 0. 32 [95% CI 0.18–0.55] p < 0.0001). Combining all 16 studies, there was a significant reduction in SSI of 58% from 12.5% to 5.2% with NPWT (RR 0.43 [95% CI 0.32–0.57] p < 0.0001). Similar effects were seen irrespective of the kind of surgery (orthopedic, abdominal, colorectal, or cesarean section), although the numbers needed to treat (NNT) were lower in operations with higher frequencies of complications. There was a significant reduction in dehiscence from 17.4% to 12.8% with NPWT (RR 0.71 [95% CI 0.54–0.92] p < 0.01). The mean reduction in hospital LOS by NPWT was also significant (−0.47 days [95% CI −0.71 to −0.23] p < 0.0001). Conclusions: The significant reduction in SSI, wound dehiscence, and LOS on the basis of pooled data from 16 studies shows a benefit of the PICO single-use NPWT system compared with standard care in closed surgical incisions. Mary Ann Liebert, Inc. 2017-10-01 2017-10-01 /pmc/articles/PMC5649123/ /pubmed/28885895 http://dx.doi.org/10.1089/sur.2017.156 Text en © Vicki Strugala and Robin Martin, 2017; Published by Mary Ann Liebert, Inc. This Open Access article is distributed under the terms of the Creative Commons License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. |
spellingShingle | Original Articles Strugala, Vicki Martin, Robin Meta-Analysis of Comparative Trials Evaluating a Prophylactic Single-Use Negative Pressure Wound Therapy System for the Prevention of Surgical Site Complications |
title | Meta-Analysis of Comparative Trials Evaluating a Prophylactic Single-Use Negative Pressure Wound Therapy System for the Prevention of Surgical Site Complications |
title_full | Meta-Analysis of Comparative Trials Evaluating a Prophylactic Single-Use Negative Pressure Wound Therapy System for the Prevention of Surgical Site Complications |
title_fullStr | Meta-Analysis of Comparative Trials Evaluating a Prophylactic Single-Use Negative Pressure Wound Therapy System for the Prevention of Surgical Site Complications |
title_full_unstemmed | Meta-Analysis of Comparative Trials Evaluating a Prophylactic Single-Use Negative Pressure Wound Therapy System for the Prevention of Surgical Site Complications |
title_short | Meta-Analysis of Comparative Trials Evaluating a Prophylactic Single-Use Negative Pressure Wound Therapy System for the Prevention of Surgical Site Complications |
title_sort | meta-analysis of comparative trials evaluating a prophylactic single-use negative pressure wound therapy system for the prevention of surgical site complications |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5649123/ https://www.ncbi.nlm.nih.gov/pubmed/28885895 http://dx.doi.org/10.1089/sur.2017.156 |
work_keys_str_mv | AT strugalavicki metaanalysisofcomparativetrialsevaluatingaprophylacticsingleusenegativepressurewoundtherapysystemforthepreventionofsurgicalsitecomplications AT martinrobin metaanalysisofcomparativetrialsevaluatingaprophylacticsingleusenegativepressurewoundtherapysystemforthepreventionofsurgicalsitecomplications |