Cargando…
Early and aggressive ISR with a polymer- and carrier-free drug-coated stent system
The LEADERS FREE trial concluded that the polymer free drug-coated BioFreedom™ stent appeared to be both safer and more effective than bare-metal stents (BMS) with an ISR rate comparable to traditional DES without the need for prolonged DAPT. We implanted 45 BioFreedom™ stents in 34 patients over a...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5650585/ https://www.ncbi.nlm.nih.gov/pubmed/29054192 http://dx.doi.org/10.1016/j.ihj.2017.03.002 |
_version_ | 1783272727281401856 |
---|---|
author | Loch, Alexander Bewersdorf, Jan Philipp Veeriah, Ramesh Singh |
author_facet | Loch, Alexander Bewersdorf, Jan Philipp Veeriah, Ramesh Singh |
author_sort | Loch, Alexander |
collection | PubMed |
description | The LEADERS FREE trial concluded that the polymer free drug-coated BioFreedom™ stent appeared to be both safer and more effective than bare-metal stents (BMS) with an ISR rate comparable to traditional DES without the need for prolonged DAPT. We implanted 45 BioFreedom™ stents in 34 patients over a 4-month period. 4 patients represented early (106–238 days after the implant procedure) with angina symptoms and severe ISR was detected in all patients. The rate of severe and early ISR detected in our patient population of 11.8% is comparable to that of traditional BMS. Further studies are warranted. |
format | Online Article Text |
id | pubmed-5650585 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-56505852018-09-01 Early and aggressive ISR with a polymer- and carrier-free drug-coated stent system Loch, Alexander Bewersdorf, Jan Philipp Veeriah, Ramesh Singh Indian Heart J Short Communication The LEADERS FREE trial concluded that the polymer free drug-coated BioFreedom™ stent appeared to be both safer and more effective than bare-metal stents (BMS) with an ISR rate comparable to traditional DES without the need for prolonged DAPT. We implanted 45 BioFreedom™ stents in 34 patients over a 4-month period. 4 patients represented early (106–238 days after the implant procedure) with angina symptoms and severe ISR was detected in all patients. The rate of severe and early ISR detected in our patient population of 11.8% is comparable to that of traditional BMS. Further studies are warranted. Elsevier 2017 2017-03-17 /pmc/articles/PMC5650585/ /pubmed/29054192 http://dx.doi.org/10.1016/j.ihj.2017.03.002 Text en © 2017 Published by Elsevier, a division of Reed Elsevier India, Pvt. Ltd. on behalf of Cardiological Society of India. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Short Communication Loch, Alexander Bewersdorf, Jan Philipp Veeriah, Ramesh Singh Early and aggressive ISR with a polymer- and carrier-free drug-coated stent system |
title | Early and aggressive ISR with a polymer- and carrier-free drug-coated stent system |
title_full | Early and aggressive ISR with a polymer- and carrier-free drug-coated stent system |
title_fullStr | Early and aggressive ISR with a polymer- and carrier-free drug-coated stent system |
title_full_unstemmed | Early and aggressive ISR with a polymer- and carrier-free drug-coated stent system |
title_short | Early and aggressive ISR with a polymer- and carrier-free drug-coated stent system |
title_sort | early and aggressive isr with a polymer- and carrier-free drug-coated stent system |
topic | Short Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5650585/ https://www.ncbi.nlm.nih.gov/pubmed/29054192 http://dx.doi.org/10.1016/j.ihj.2017.03.002 |
work_keys_str_mv | AT lochalexander earlyandaggressiveisrwithapolymerandcarrierfreedrugcoatedstentsystem AT bewersdorfjanphilipp earlyandaggressiveisrwithapolymerandcarrierfreedrugcoatedstentsystem AT veeriahrameshsingh earlyandaggressiveisrwithapolymerandcarrierfreedrugcoatedstentsystem |