Cargando…

Agreement between Electrocardiogram and Heart Rate Meter Is Low for the Measurement of Heart Rate Variability during Exercise in Young Endurance Horses

Analysis of the heart rate variability (HRV) gains more and more importance in the assessment of training practice and welfare in equine industry. It relies on mathematical analyses of reliably and accurately measured variations in successive inter-beat intervals, measured as RR intervals. Nowadays,...

Descripción completa

Detalles Bibliográficos
Autores principales: Lenoir, Augustin, Trachsel, Dagmar S., Younes, Mohamed, Barrey, Eric, Robert, Céline
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5650972/
https://www.ncbi.nlm.nih.gov/pubmed/29090214
http://dx.doi.org/10.3389/fvets.2017.00170
_version_ 1783272800280117248
author Lenoir, Augustin
Trachsel, Dagmar S.
Younes, Mohamed
Barrey, Eric
Robert, Céline
author_facet Lenoir, Augustin
Trachsel, Dagmar S.
Younes, Mohamed
Barrey, Eric
Robert, Céline
author_sort Lenoir, Augustin
collection PubMed
description Analysis of the heart rate variability (HRV) gains more and more importance in the assessment of training practice and welfare in equine industry. It relies on mathematical analyses of reliably and accurately measured variations in successive inter-beat intervals, measured as RR intervals. Nowadays, the RR intervals can be obtained through two different techniques: a heart rate meter (HRM) or an electrocardiogram (ECG). The agreement and reliability of these devices has not been fully assessed, especially for recordings during exercise. The purpose of this study was to assess the agreement of two commercially available devices using the two mentioned techniques (HRM vs ECG) for HRV analysis during a standardized exercise test. Simultaneous recordings obtained during light exercise and during canter with both devices were available for 36 horses. Data were compared using a Bland–Altman analysis and the Lin’s coefficient. The agreement between the assessed HRV measures from the data obtained from the ECG and HRM was acceptable only for the mean RR interval and the mean heart rate. For the other studied measures (SDNN, root mean square of successive differences, SD1, SD2, low frequency, high frequency), the agreement between the devices was too poor for them to be considered as interchangeable in these recording conditions. The agreement tended also to be worse when speed of the exercise increased. Therefore, it is necessary to be careful when interpreting and comparing results of HRV analysis during exercise, as the results will depend upon recording devices. Furthermore, corrections and data processing included in the software of the devices affect largely the output used in the subsequent HRV analysis; this must be considered in the choice of the device.
format Online
Article
Text
id pubmed-5650972
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-56509722017-10-31 Agreement between Electrocardiogram and Heart Rate Meter Is Low for the Measurement of Heart Rate Variability during Exercise in Young Endurance Horses Lenoir, Augustin Trachsel, Dagmar S. Younes, Mohamed Barrey, Eric Robert, Céline Front Vet Sci Veterinary Science Analysis of the heart rate variability (HRV) gains more and more importance in the assessment of training practice and welfare in equine industry. It relies on mathematical analyses of reliably and accurately measured variations in successive inter-beat intervals, measured as RR intervals. Nowadays, the RR intervals can be obtained through two different techniques: a heart rate meter (HRM) or an electrocardiogram (ECG). The agreement and reliability of these devices has not been fully assessed, especially for recordings during exercise. The purpose of this study was to assess the agreement of two commercially available devices using the two mentioned techniques (HRM vs ECG) for HRV analysis during a standardized exercise test. Simultaneous recordings obtained during light exercise and during canter with both devices were available for 36 horses. Data were compared using a Bland–Altman analysis and the Lin’s coefficient. The agreement between the assessed HRV measures from the data obtained from the ECG and HRM was acceptable only for the mean RR interval and the mean heart rate. For the other studied measures (SDNN, root mean square of successive differences, SD1, SD2, low frequency, high frequency), the agreement between the devices was too poor for them to be considered as interchangeable in these recording conditions. The agreement tended also to be worse when speed of the exercise increased. Therefore, it is necessary to be careful when interpreting and comparing results of HRV analysis during exercise, as the results will depend upon recording devices. Furthermore, corrections and data processing included in the software of the devices affect largely the output used in the subsequent HRV analysis; this must be considered in the choice of the device. Frontiers Media S.A. 2017-10-17 /pmc/articles/PMC5650972/ /pubmed/29090214 http://dx.doi.org/10.3389/fvets.2017.00170 Text en Copyright © 2017 Lenoir, Trachsel, Younes, Barrey and Robert. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Veterinary Science
Lenoir, Augustin
Trachsel, Dagmar S.
Younes, Mohamed
Barrey, Eric
Robert, Céline
Agreement between Electrocardiogram and Heart Rate Meter Is Low for the Measurement of Heart Rate Variability during Exercise in Young Endurance Horses
title Agreement between Electrocardiogram and Heart Rate Meter Is Low for the Measurement of Heart Rate Variability during Exercise in Young Endurance Horses
title_full Agreement between Electrocardiogram and Heart Rate Meter Is Low for the Measurement of Heart Rate Variability during Exercise in Young Endurance Horses
title_fullStr Agreement between Electrocardiogram and Heart Rate Meter Is Low for the Measurement of Heart Rate Variability during Exercise in Young Endurance Horses
title_full_unstemmed Agreement between Electrocardiogram and Heart Rate Meter Is Low for the Measurement of Heart Rate Variability during Exercise in Young Endurance Horses
title_short Agreement between Electrocardiogram and Heart Rate Meter Is Low for the Measurement of Heart Rate Variability during Exercise in Young Endurance Horses
title_sort agreement between electrocardiogram and heart rate meter is low for the measurement of heart rate variability during exercise in young endurance horses
topic Veterinary Science
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5650972/
https://www.ncbi.nlm.nih.gov/pubmed/29090214
http://dx.doi.org/10.3389/fvets.2017.00170
work_keys_str_mv AT lenoiraugustin agreementbetweenelectrocardiogramandheartratemeterislowforthemeasurementofheartratevariabilityduringexerciseinyoungendurancehorses
AT trachseldagmars agreementbetweenelectrocardiogramandheartratemeterislowforthemeasurementofheartratevariabilityduringexerciseinyoungendurancehorses
AT younesmohamed agreementbetweenelectrocardiogramandheartratemeterislowforthemeasurementofheartratevariabilityduringexerciseinyoungendurancehorses
AT barreyeric agreementbetweenelectrocardiogramandheartratemeterislowforthemeasurementofheartratevariabilityduringexerciseinyoungendurancehorses
AT robertceline agreementbetweenelectrocardiogramandheartratemeterislowforthemeasurementofheartratevariabilityduringexerciseinyoungendurancehorses