Cargando…
Absolute Reliability and Concurrent Validity of Hand Held Dynamometry and Isokinetic Dynamometry in the Hip, Knee and Ankle Joint: Systematic Review and Meta-analysis
The purpose of the study is to establish absolute reliability and concurrent validity between hand-held dynamometers (HHDs) and isokinetic dynamometers (IDs) in lower extremity peak torque assessment. Medline, Embase, CINAHL databases were searched for studies related to psychometric properties in m...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
De Gruyter Open
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5651404/ https://www.ncbi.nlm.nih.gov/pubmed/29071305 http://dx.doi.org/10.1515/med-2017-0052 |
_version_ | 1783272886012739584 |
---|---|
author | Chamorro, Claudio Armijo-Olivo, Susan De la Fuente, Carlos Fuentes, Javiera Javier Chirosa, Luis |
author_facet | Chamorro, Claudio Armijo-Olivo, Susan De la Fuente, Carlos Fuentes, Javiera Javier Chirosa, Luis |
author_sort | Chamorro, Claudio |
collection | PubMed |
description | The purpose of the study is to establish absolute reliability and concurrent validity between hand-held dynamometers (HHDs) and isokinetic dynamometers (IDs) in lower extremity peak torque assessment. Medline, Embase, CINAHL databases were searched for studies related to psychometric properties in muscle dynamometry. Studies considering standard error of measurement SEM (%) or limit of agreement LOA (%) expressed as percentage of the mean, were considered to establish absolute reliability while studies using intra-class correlation coefficient (ICC) were considered to establish concurrent validity between dynamometers. In total, 17 studies were included in the meta-analysis. The COSMIN checklist classified them between fair and poor. Using HHDs, knee extension LOA (%) was 33.59%, 95% confidence interval (CI) 23.91 to 43.26 and ankle plantar flexion LOA (%) was 48.87%, CI 35.19 to 62.56. Using IDs, hip adduction and extension; knee flexion and extension; and ankle dorsiflexion showed LOA (%) under 15%. Lower hip, knee, and ankle LOA (%) were obtained using an ID compared to HHD. ICC between devices ranged between 0.62, CI (0.37 to 0.87) for ankle dorsiflexion to 0.94, IC (0.91to 0.98) for hip adduction. Very high correlation were found for hip adductors and hip flexors and moderate correlations for knee flexors/extensors and ankle plantar/dorsiflexors. |
format | Online Article Text |
id | pubmed-5651404 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | De Gruyter Open |
record_format | MEDLINE/PubMed |
spelling | pubmed-56514042017-10-25 Absolute Reliability and Concurrent Validity of Hand Held Dynamometry and Isokinetic Dynamometry in the Hip, Knee and Ankle Joint: Systematic Review and Meta-analysis Chamorro, Claudio Armijo-Olivo, Susan De la Fuente, Carlos Fuentes, Javiera Javier Chirosa, Luis Open Med (Wars) Regular Articles The purpose of the study is to establish absolute reliability and concurrent validity between hand-held dynamometers (HHDs) and isokinetic dynamometers (IDs) in lower extremity peak torque assessment. Medline, Embase, CINAHL databases were searched for studies related to psychometric properties in muscle dynamometry. Studies considering standard error of measurement SEM (%) or limit of agreement LOA (%) expressed as percentage of the mean, were considered to establish absolute reliability while studies using intra-class correlation coefficient (ICC) were considered to establish concurrent validity between dynamometers. In total, 17 studies were included in the meta-analysis. The COSMIN checklist classified them between fair and poor. Using HHDs, knee extension LOA (%) was 33.59%, 95% confidence interval (CI) 23.91 to 43.26 and ankle plantar flexion LOA (%) was 48.87%, CI 35.19 to 62.56. Using IDs, hip adduction and extension; knee flexion and extension; and ankle dorsiflexion showed LOA (%) under 15%. Lower hip, knee, and ankle LOA (%) were obtained using an ID compared to HHD. ICC between devices ranged between 0.62, CI (0.37 to 0.87) for ankle dorsiflexion to 0.94, IC (0.91to 0.98) for hip adduction. Very high correlation were found for hip adductors and hip flexors and moderate correlations for knee flexors/extensors and ankle plantar/dorsiflexors. De Gruyter Open 2017-10-17 /pmc/articles/PMC5651404/ /pubmed/29071305 http://dx.doi.org/10.1515/med-2017-0052 Text en © 2017 Claudio Chamorro et al. http://creativecommons.org/licenses/by-nc-nd/4.0 This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License. |
spellingShingle | Regular Articles Chamorro, Claudio Armijo-Olivo, Susan De la Fuente, Carlos Fuentes, Javiera Javier Chirosa, Luis Absolute Reliability and Concurrent Validity of Hand Held Dynamometry and Isokinetic Dynamometry in the Hip, Knee and Ankle Joint: Systematic Review and Meta-analysis |
title | Absolute Reliability and Concurrent Validity of Hand Held Dynamometry and Isokinetic Dynamometry in the Hip, Knee and Ankle Joint: Systematic Review and Meta-analysis |
title_full | Absolute Reliability and Concurrent Validity of Hand Held Dynamometry and Isokinetic Dynamometry in the Hip, Knee and Ankle Joint: Systematic Review and Meta-analysis |
title_fullStr | Absolute Reliability and Concurrent Validity of Hand Held Dynamometry and Isokinetic Dynamometry in the Hip, Knee and Ankle Joint: Systematic Review and Meta-analysis |
title_full_unstemmed | Absolute Reliability and Concurrent Validity of Hand Held Dynamometry and Isokinetic Dynamometry in the Hip, Knee and Ankle Joint: Systematic Review and Meta-analysis |
title_short | Absolute Reliability and Concurrent Validity of Hand Held Dynamometry and Isokinetic Dynamometry in the Hip, Knee and Ankle Joint: Systematic Review and Meta-analysis |
title_sort | absolute reliability and concurrent validity of hand held dynamometry and isokinetic dynamometry in the hip, knee and ankle joint: systematic review and meta-analysis |
topic | Regular Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5651404/ https://www.ncbi.nlm.nih.gov/pubmed/29071305 http://dx.doi.org/10.1515/med-2017-0052 |
work_keys_str_mv | AT chamorroclaudio absolutereliabilityandconcurrentvalidityofhandhelddynamometryandisokineticdynamometryinthehipkneeandanklejointsystematicreviewandmetaanalysis AT armijoolivosusan absolutereliabilityandconcurrentvalidityofhandhelddynamometryandisokineticdynamometryinthehipkneeandanklejointsystematicreviewandmetaanalysis AT delafuentecarlos absolutereliabilityandconcurrentvalidityofhandhelddynamometryandisokineticdynamometryinthehipkneeandanklejointsystematicreviewandmetaanalysis AT fuentesjaviera absolutereliabilityandconcurrentvalidityofhandhelddynamometryandisokineticdynamometryinthehipkneeandanklejointsystematicreviewandmetaanalysis AT javierchirosaluis absolutereliabilityandconcurrentvalidityofhandhelddynamometryandisokineticdynamometryinthehipkneeandanklejointsystematicreviewandmetaanalysis |