Intra-observer and inter-observer reliability of leg circumference measurement among six observers: a single blinded randomized trial

Hypothesis: Circumference measurement of extremities that was reported to be a reliable method as long as being standardized is commonly used both in clinical and home settings by clinicians or caregivers due to its cheapness and easy use. Objectives: The aims of this study were to determine the int...

Descripción completa

Detalles Bibliográficos
Autores principales: Bakar, Y, Özdemir, ÖC, Sevim, S, Duygu, E, Tuğral, A, Sürmeli, M
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Carol Davila University Press 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5652265/
https://www.ncbi.nlm.nih.gov/pubmed/29075347
_version_ 1783273040423944192
author Bakar, Y
Özdemir, ÖC
Sevim, S
Duygu, E
Tuğral, A
Sürmeli, M
author_facet Bakar, Y
Özdemir, ÖC
Sevim, S
Duygu, E
Tuğral, A
Sürmeli, M
author_sort Bakar, Y
collection PubMed
description Hypothesis: Circumference measurement of extremities that was reported to be a reliable method as long as being standardized is commonly used both in clinical and home settings by clinicians or caregivers due to its cheapness and easy use. Objectives: The aims of this study were to determine the inter-observer and intra-observer reliability of manual circumference measurement among different observers and various measurement points. Methods and Results: A total of 58 lower limbs were included in the study. Both lower limbs of each subject were assessed by 6 observers randomly using circumference measurement method from 9 reference points specified with a Leg-O-Meter. All observers performed the measurements and they were blind to each other’s measurements. Results: Measurement results from reference points were statistically significant between good to perfect (ICC 0.65-0.99, p<0.001). Interrater reliability of all observers’ first and second measurements showed perfect reliability for both measurements (ICC: 0.92-0.99, p<0.001). Conclusions: This study demonstrated that the lower extremity manual circumference measurement is a reliable method for clinical practice. Abbreviations: BMI = Body Mass Index, ICC = Intraclass Correlation Coefficient, Metatarsal heads (cA), Ankle-heel (cY), Ankle (cB), Distal beginning point of gastrocnemius (cB1), The widest point for gastrocnemius (cC), Head of fibula (cD), Midline of knee (cE), Midline of thigh (cF), Groin level (cG)
format Online
Article
Text
id pubmed-5652265
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Carol Davila University Press
record_format MEDLINE/PubMed
spelling pubmed-56522652017-10-26 Intra-observer and inter-observer reliability of leg circumference measurement among six observers: a single blinded randomized trial Bakar, Y Özdemir, ÖC Sevim, S Duygu, E Tuğral, A Sürmeli, M J Med Life Original Articles Hypothesis: Circumference measurement of extremities that was reported to be a reliable method as long as being standardized is commonly used both in clinical and home settings by clinicians or caregivers due to its cheapness and easy use. Objectives: The aims of this study were to determine the inter-observer and intra-observer reliability of manual circumference measurement among different observers and various measurement points. Methods and Results: A total of 58 lower limbs were included in the study. Both lower limbs of each subject were assessed by 6 observers randomly using circumference measurement method from 9 reference points specified with a Leg-O-Meter. All observers performed the measurements and they were blind to each other’s measurements. Results: Measurement results from reference points were statistically significant between good to perfect (ICC 0.65-0.99, p<0.001). Interrater reliability of all observers’ first and second measurements showed perfect reliability for both measurements (ICC: 0.92-0.99, p<0.001). Conclusions: This study demonstrated that the lower extremity manual circumference measurement is a reliable method for clinical practice. Abbreviations: BMI = Body Mass Index, ICC = Intraclass Correlation Coefficient, Metatarsal heads (cA), Ankle-heel (cY), Ankle (cB), Distal beginning point of gastrocnemius (cB1), The widest point for gastrocnemius (cC), Head of fibula (cD), Midline of knee (cE), Midline of thigh (cF), Groin level (cG) Carol Davila University Press 2017 /pmc/articles/PMC5652265/ /pubmed/29075347 Text en ©Carol Davila University Press This article is distributed under the terms of the Creative Commons Attribution License ( http://creativecommons.org/licenses/by/3.0/), which permits unrestricted use and redistribution provided that the original author and source are credited.
spellingShingle Original Articles
Bakar, Y
Özdemir, ÖC
Sevim, S
Duygu, E
Tuğral, A
Sürmeli, M
Intra-observer and inter-observer reliability of leg circumference measurement among six observers: a single blinded randomized trial
title Intra-observer and inter-observer reliability of leg circumference measurement among six observers: a single blinded randomized trial
title_full Intra-observer and inter-observer reliability of leg circumference measurement among six observers: a single blinded randomized trial
title_fullStr Intra-observer and inter-observer reliability of leg circumference measurement among six observers: a single blinded randomized trial
title_full_unstemmed Intra-observer and inter-observer reliability of leg circumference measurement among six observers: a single blinded randomized trial
title_short Intra-observer and inter-observer reliability of leg circumference measurement among six observers: a single blinded randomized trial
title_sort intra-observer and inter-observer reliability of leg circumference measurement among six observers: a single blinded randomized trial
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5652265/
https://www.ncbi.nlm.nih.gov/pubmed/29075347
work_keys_str_mv AT bakary intraobserverandinterobserverreliabilityoflegcircumferencemeasurementamongsixobserversasingleblindedrandomizedtrial
AT ozdemiroc intraobserverandinterobserverreliabilityoflegcircumferencemeasurementamongsixobserversasingleblindedrandomizedtrial
AT sevims intraobserverandinterobserverreliabilityoflegcircumferencemeasurementamongsixobserversasingleblindedrandomizedtrial
AT duygue intraobserverandinterobserverreliabilityoflegcircumferencemeasurementamongsixobserversasingleblindedrandomizedtrial
AT tugrala intraobserverandinterobserverreliabilityoflegcircumferencemeasurementamongsixobserversasingleblindedrandomizedtrial
AT surmelim intraobserverandinterobserverreliabilityoflegcircumferencemeasurementamongsixobserversasingleblindedrandomizedtrial