Cargando…

Evaluation of AISI Type 304 stainless steel as a suitable surface material for evaluating the efficacy of peracetic acid-based disinfectants against Clostridium difficile spores

Disinfectants play an important role in controlling microbial contamination on hard surfaces in hospitals. The effectiveness of disinfectants in real life can be predicted by laboratory tests that measure killing of microbes on carriers. The modified Quantitative Disk Carrier Test (QCT-2) is a stand...

Descripción completa

Detalles Bibliográficos
Autores principales: Black, Elaine, Owens, Krista, Staub, Richard, Li, Junzhong, Mills, Kristen, Valenstein, Justin, Hilgren, John
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5655606/
https://www.ncbi.nlm.nih.gov/pubmed/29065168
http://dx.doi.org/10.1371/journal.pone.0187074
_version_ 1783273564260007936
author Black, Elaine
Owens, Krista
Staub, Richard
Li, Junzhong
Mills, Kristen
Valenstein, Justin
Hilgren, John
author_facet Black, Elaine
Owens, Krista
Staub, Richard
Li, Junzhong
Mills, Kristen
Valenstein, Justin
Hilgren, John
author_sort Black, Elaine
collection PubMed
description Disinfectants play an important role in controlling microbial contamination on hard surfaces in hospitals. The effectiveness of disinfectants in real life can be predicted by laboratory tests that measure killing of microbes on carriers. The modified Quantitative Disk Carrier Test (QCT-2) is a standard laboratory method that employs American Iron and Steel Institute (AISI) Type 430 stainless steel carriers to measure hospital disinfectant efficacy against Clostridium difficile spores. The formation of a rust-colored precipitate was observed on Type 430 carriers when testing a peracetic acid (PAA)-based disinfectant with the QCT-2 method. It was hypothesized that the precipitate was indicative of corrosion of the Type 430 carrier, and that corrosion could impact efficacy results. The objective of this study was to compare the suitability of AISI Type 430 to Type 304 stainless steel carriers for evaluating PAA-based disinfectants using the QCT-2 method. Type 304 is more corrosion-resistant than Type 430, is ubiquitous in healthcare environments, and is used in other standard methods. Suitability of the carriers was evaluated by comparing their impacts on efficacy results and PAA degradation rates. In efficacy tests with 1376 ppm PAA, reductions of C. difficile spores after 5, 7 and 10 minutes on Type 430 carriers were at least about 1.5 log(10) lower than reductions on Type 304 carriers. In conditions simulating a QCT-2 test, PAA concentration with Type 430 carriers was reduced by approximately 80% in 10 minutes, whereas PAA concentration in the presence of Type 304 carriers remained stable. Elemental analyses of residues on each carrier type after efficacy testing were indicative of corrosion on the Type 430 carrier. Use of Type 430 stainless steel carriers for measuring the efficacy of PAA-based disinfectants should be avoided as it can lead to an underestimation of real life sporicidal efficacy. Type 304 stainless steel carriers are recommended as a suitable alternative.
format Online
Article
Text
id pubmed-5655606
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-56556062017-11-09 Evaluation of AISI Type 304 stainless steel as a suitable surface material for evaluating the efficacy of peracetic acid-based disinfectants against Clostridium difficile spores Black, Elaine Owens, Krista Staub, Richard Li, Junzhong Mills, Kristen Valenstein, Justin Hilgren, John PLoS One Research Article Disinfectants play an important role in controlling microbial contamination on hard surfaces in hospitals. The effectiveness of disinfectants in real life can be predicted by laboratory tests that measure killing of microbes on carriers. The modified Quantitative Disk Carrier Test (QCT-2) is a standard laboratory method that employs American Iron and Steel Institute (AISI) Type 430 stainless steel carriers to measure hospital disinfectant efficacy against Clostridium difficile spores. The formation of a rust-colored precipitate was observed on Type 430 carriers when testing a peracetic acid (PAA)-based disinfectant with the QCT-2 method. It was hypothesized that the precipitate was indicative of corrosion of the Type 430 carrier, and that corrosion could impact efficacy results. The objective of this study was to compare the suitability of AISI Type 430 to Type 304 stainless steel carriers for evaluating PAA-based disinfectants using the QCT-2 method. Type 304 is more corrosion-resistant than Type 430, is ubiquitous in healthcare environments, and is used in other standard methods. Suitability of the carriers was evaluated by comparing their impacts on efficacy results and PAA degradation rates. In efficacy tests with 1376 ppm PAA, reductions of C. difficile spores after 5, 7 and 10 minutes on Type 430 carriers were at least about 1.5 log(10) lower than reductions on Type 304 carriers. In conditions simulating a QCT-2 test, PAA concentration with Type 430 carriers was reduced by approximately 80% in 10 minutes, whereas PAA concentration in the presence of Type 304 carriers remained stable. Elemental analyses of residues on each carrier type after efficacy testing were indicative of corrosion on the Type 430 carrier. Use of Type 430 stainless steel carriers for measuring the efficacy of PAA-based disinfectants should be avoided as it can lead to an underestimation of real life sporicidal efficacy. Type 304 stainless steel carriers are recommended as a suitable alternative. Public Library of Science 2017-10-24 /pmc/articles/PMC5655606/ /pubmed/29065168 http://dx.doi.org/10.1371/journal.pone.0187074 Text en © 2017 Black et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Black, Elaine
Owens, Krista
Staub, Richard
Li, Junzhong
Mills, Kristen
Valenstein, Justin
Hilgren, John
Evaluation of AISI Type 304 stainless steel as a suitable surface material for evaluating the efficacy of peracetic acid-based disinfectants against Clostridium difficile spores
title Evaluation of AISI Type 304 stainless steel as a suitable surface material for evaluating the efficacy of peracetic acid-based disinfectants against Clostridium difficile spores
title_full Evaluation of AISI Type 304 stainless steel as a suitable surface material for evaluating the efficacy of peracetic acid-based disinfectants against Clostridium difficile spores
title_fullStr Evaluation of AISI Type 304 stainless steel as a suitable surface material for evaluating the efficacy of peracetic acid-based disinfectants against Clostridium difficile spores
title_full_unstemmed Evaluation of AISI Type 304 stainless steel as a suitable surface material for evaluating the efficacy of peracetic acid-based disinfectants against Clostridium difficile spores
title_short Evaluation of AISI Type 304 stainless steel as a suitable surface material for evaluating the efficacy of peracetic acid-based disinfectants against Clostridium difficile spores
title_sort evaluation of aisi type 304 stainless steel as a suitable surface material for evaluating the efficacy of peracetic acid-based disinfectants against clostridium difficile spores
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5655606/
https://www.ncbi.nlm.nih.gov/pubmed/29065168
http://dx.doi.org/10.1371/journal.pone.0187074
work_keys_str_mv AT blackelaine evaluationofaisitype304stainlesssteelasasuitablesurfacematerialforevaluatingtheefficacyofperaceticacidbaseddisinfectantsagainstclostridiumdifficilespores
AT owenskrista evaluationofaisitype304stainlesssteelasasuitablesurfacematerialforevaluatingtheefficacyofperaceticacidbaseddisinfectantsagainstclostridiumdifficilespores
AT staubrichard evaluationofaisitype304stainlesssteelasasuitablesurfacematerialforevaluatingtheefficacyofperaceticacidbaseddisinfectantsagainstclostridiumdifficilespores
AT lijunzhong evaluationofaisitype304stainlesssteelasasuitablesurfacematerialforevaluatingtheefficacyofperaceticacidbaseddisinfectantsagainstclostridiumdifficilespores
AT millskristen evaluationofaisitype304stainlesssteelasasuitablesurfacematerialforevaluatingtheefficacyofperaceticacidbaseddisinfectantsagainstclostridiumdifficilespores
AT valensteinjustin evaluationofaisitype304stainlesssteelasasuitablesurfacematerialforevaluatingtheefficacyofperaceticacidbaseddisinfectantsagainstclostridiumdifficilespores
AT hilgrenjohn evaluationofaisitype304stainlesssteelasasuitablesurfacematerialforevaluatingtheefficacyofperaceticacidbaseddisinfectantsagainstclostridiumdifficilespores