Cargando…

Isolated pulmonary regurgitation causes decreased right ventricular longitudinal function and compensatory increased septal pumping in a porcine model

AIM: Longitudinal ventricular contraction is a parameter of cardiac performance with predictive power. Right ventricular (RV) longitudinal function is impaired in patients with free pulmonary regurgitation (PR) following corrective surgery for Tetralogy of Fallot (TOF). It remains unclear whether th...

Descripción completa

Detalles Bibliográficos
Autores principales: Kopic, S., Stephensen, S. S., Heiberg, E., Arheden, H., Bonhoeffer, P., Ersbøll, M., Vejlstrup, N., Søndergaard, L., Carlsson, M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5655773/
https://www.ncbi.nlm.nih.gov/pubmed/28580611
http://dx.doi.org/10.1111/apha.12904
_version_ 1783273600591069184
author Kopic, S.
Stephensen, S. S.
Heiberg, E.
Arheden, H.
Bonhoeffer, P.
Ersbøll, M.
Vejlstrup, N.
Søndergaard, L.
Carlsson, M.
author_facet Kopic, S.
Stephensen, S. S.
Heiberg, E.
Arheden, H.
Bonhoeffer, P.
Ersbøll, M.
Vejlstrup, N.
Søndergaard, L.
Carlsson, M.
author_sort Kopic, S.
collection PubMed
description AIM: Longitudinal ventricular contraction is a parameter of cardiac performance with predictive power. Right ventricular (RV) longitudinal function is impaired in patients with free pulmonary regurgitation (PR) following corrective surgery for Tetralogy of Fallot (TOF). It remains unclear whether this is a consequence of the surgical repair, or whether it is inherent to PR. The aim of this study was to assess the relationship between longitudinal, lateral and septal pumping in a porcine model of isolated PR. METHODS: Piglets were divided into a control (n = 8) group and a treatment (n = 12) group, which received a stent in the pulmonary valve orifice, inducing PR. After 2–3 months, animals were subjected to cardiac magnetic resonance imaging. A subset of animals (n = 6) then underwent percutaneous pulmonary valve replacement (PPVR) with follow‐up 1 month later. Longitudinal, lateral and septal contributions to stroke volume (SV) were quantified by measuring volumetric displacements from end‐diastole to end‐systole in the cardiac short axis and long axis. RESULTS: PR resulted in a lower longitudinal contribution to RV stroke volume, compared to controls (60.0 ± 2.6% vs. 73.6 ± 3.8%; P = 0.012). Furthermore, a compensatory increase in septal contribution to RVSV was observed (11.0 ± 1.6% vs. −3.1 ± 1.5%; P < 0.0001). The left ventricle (LV) showed counter‐regulation with an increased longitudinal LVSV. Changes in RV longitudinal function were reversed by PPVR. CONCLUSION: These findings suggest that PR contributes to decreased RV longitudinal function in the absence of scarring from cardiac surgery. Measurement of longitudinal RVSV may aid risk stratification and timing for interventional correction of PR in TOF patients.
format Online
Article
Text
id pubmed-5655773
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-56557732017-11-01 Isolated pulmonary regurgitation causes decreased right ventricular longitudinal function and compensatory increased septal pumping in a porcine model Kopic, S. Stephensen, S. S. Heiberg, E. Arheden, H. Bonhoeffer, P. Ersbøll, M. Vejlstrup, N. Søndergaard, L. Carlsson, M. Acta Physiol (Oxf) Cardiovascular Physiology AIM: Longitudinal ventricular contraction is a parameter of cardiac performance with predictive power. Right ventricular (RV) longitudinal function is impaired in patients with free pulmonary regurgitation (PR) following corrective surgery for Tetralogy of Fallot (TOF). It remains unclear whether this is a consequence of the surgical repair, or whether it is inherent to PR. The aim of this study was to assess the relationship between longitudinal, lateral and septal pumping in a porcine model of isolated PR. METHODS: Piglets were divided into a control (n = 8) group and a treatment (n = 12) group, which received a stent in the pulmonary valve orifice, inducing PR. After 2–3 months, animals were subjected to cardiac magnetic resonance imaging. A subset of animals (n = 6) then underwent percutaneous pulmonary valve replacement (PPVR) with follow‐up 1 month later. Longitudinal, lateral and septal contributions to stroke volume (SV) were quantified by measuring volumetric displacements from end‐diastole to end‐systole in the cardiac short axis and long axis. RESULTS: PR resulted in a lower longitudinal contribution to RV stroke volume, compared to controls (60.0 ± 2.6% vs. 73.6 ± 3.8%; P = 0.012). Furthermore, a compensatory increase in septal contribution to RVSV was observed (11.0 ± 1.6% vs. −3.1 ± 1.5%; P < 0.0001). The left ventricle (LV) showed counter‐regulation with an increased longitudinal LVSV. Changes in RV longitudinal function were reversed by PPVR. CONCLUSION: These findings suggest that PR contributes to decreased RV longitudinal function in the absence of scarring from cardiac surgery. Measurement of longitudinal RVSV may aid risk stratification and timing for interventional correction of PR in TOF patients. John Wiley and Sons Inc. 2017-06-29 2017-11 /pmc/articles/PMC5655773/ /pubmed/28580611 http://dx.doi.org/10.1111/apha.12904 Text en © 2017 The Authors. Acta Physiologica published by John Wiley & Sons Ltd on behalf of Scandinavian Physiological Society This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Cardiovascular Physiology
Kopic, S.
Stephensen, S. S.
Heiberg, E.
Arheden, H.
Bonhoeffer, P.
Ersbøll, M.
Vejlstrup, N.
Søndergaard, L.
Carlsson, M.
Isolated pulmonary regurgitation causes decreased right ventricular longitudinal function and compensatory increased septal pumping in a porcine model
title Isolated pulmonary regurgitation causes decreased right ventricular longitudinal function and compensatory increased septal pumping in a porcine model
title_full Isolated pulmonary regurgitation causes decreased right ventricular longitudinal function and compensatory increased septal pumping in a porcine model
title_fullStr Isolated pulmonary regurgitation causes decreased right ventricular longitudinal function and compensatory increased septal pumping in a porcine model
title_full_unstemmed Isolated pulmonary regurgitation causes decreased right ventricular longitudinal function and compensatory increased septal pumping in a porcine model
title_short Isolated pulmonary regurgitation causes decreased right ventricular longitudinal function and compensatory increased septal pumping in a porcine model
title_sort isolated pulmonary regurgitation causes decreased right ventricular longitudinal function and compensatory increased septal pumping in a porcine model
topic Cardiovascular Physiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5655773/
https://www.ncbi.nlm.nih.gov/pubmed/28580611
http://dx.doi.org/10.1111/apha.12904
work_keys_str_mv AT kopics isolatedpulmonaryregurgitationcausesdecreasedrightventricularlongitudinalfunctionandcompensatoryincreasedseptalpumpinginaporcinemodel
AT stephensenss isolatedpulmonaryregurgitationcausesdecreasedrightventricularlongitudinalfunctionandcompensatoryincreasedseptalpumpinginaporcinemodel
AT heiberge isolatedpulmonaryregurgitationcausesdecreasedrightventricularlongitudinalfunctionandcompensatoryincreasedseptalpumpinginaporcinemodel
AT arhedenh isolatedpulmonaryregurgitationcausesdecreasedrightventricularlongitudinalfunctionandcompensatoryincreasedseptalpumpinginaporcinemodel
AT bonhoefferp isolatedpulmonaryregurgitationcausesdecreasedrightventricularlongitudinalfunctionandcompensatoryincreasedseptalpumpinginaporcinemodel
AT ersbøllm isolatedpulmonaryregurgitationcausesdecreasedrightventricularlongitudinalfunctionandcompensatoryincreasedseptalpumpinginaporcinemodel
AT vejlstrupn isolatedpulmonaryregurgitationcausesdecreasedrightventricularlongitudinalfunctionandcompensatoryincreasedseptalpumpinginaporcinemodel
AT søndergaardl isolatedpulmonaryregurgitationcausesdecreasedrightventricularlongitudinalfunctionandcompensatoryincreasedseptalpumpinginaporcinemodel
AT carlssonm isolatedpulmonaryregurgitationcausesdecreasedrightventricularlongitudinalfunctionandcompensatoryincreasedseptalpumpinginaporcinemodel