Cargando…

Stereolithographic model-assisted reconstruction of the mandibular condyle with a vascularized fibular flap following hemimandibulectomy: Evaluation of morphological and functional outcomes

The vascularized fibular flap is one of the standard treatment choices for the reconstruction of the mandible; however, the consequences of condylar restoration have not previously been reported. The use of three-dimensional models allows for a more predictable reconstruction. The purpose of the pre...

Descripción completa

Detalles Bibliográficos
Autores principales: Yoshimura, Hitoshi, Matsuda, Shinpei, Ohba, Seigo, Minegishi, Yoshiki, Nakai, Kunihiro, Fujieda, Shigeharu, Sano, Kazuo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: D.A. Spandidos 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5656033/
https://www.ncbi.nlm.nih.gov/pubmed/29113176
http://dx.doi.org/10.3892/ol.2017.6909
_version_ 1783273647551545344
author Yoshimura, Hitoshi
Matsuda, Shinpei
Ohba, Seigo
Minegishi, Yoshiki
Nakai, Kunihiro
Fujieda, Shigeharu
Sano, Kazuo
author_facet Yoshimura, Hitoshi
Matsuda, Shinpei
Ohba, Seigo
Minegishi, Yoshiki
Nakai, Kunihiro
Fujieda, Shigeharu
Sano, Kazuo
author_sort Yoshimura, Hitoshi
collection PubMed
description The vascularized fibular flap is one of the standard treatment choices for the reconstruction of the mandible; however, the consequences of condylar restoration have not previously been reported. The use of three-dimensional models allows for a more predictable reconstruction. The purpose of the present study was to assess the outcome of stereolithographic model-assisted reconstruction of the mandibular condyle with a vascularized fibular flap. A total of 5 patients underwent mandibular resection including the condyle and immediate reconstruction with a vascularized fibular flap. A stereolithographic model was used to determine the length and angle of the bony reconstruction. In all patients, the temporomandibular joint (TMJ) disc was preserved, and the contoured fibular end was placed directly into the glenoid fossa under the TMJ disc. To investigate the morphological and functional outcomes, radiographic and clinical examinations were performed, and a food scale questionnaire was administered. The mean period of follow-up was 23 months, and all the flaps were viable. Cosmetic results were generally satisfactory. Radiographic assessment revealed that the end of the fibular graft became round-shaped. None of the patients had abnormal bone resorption, dislocation or ankylosis. The mean value of maximum mouth opening was 31 mm. No patients exhibited difficulties with occlusion. All patients recovered their ability to ingest nearly the same foods that were ingested prior to surgery. The stereolithographic model-assisted reconstruction of mandibular condyle with a vascularized fibular flap is therefore useful for morphological and functional reconstructions of the hemimandible, including condylar defects.
format Online
Article
Text
id pubmed-5656033
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher D.A. Spandidos
record_format MEDLINE/PubMed
spelling pubmed-56560332017-11-06 Stereolithographic model-assisted reconstruction of the mandibular condyle with a vascularized fibular flap following hemimandibulectomy: Evaluation of morphological and functional outcomes Yoshimura, Hitoshi Matsuda, Shinpei Ohba, Seigo Minegishi, Yoshiki Nakai, Kunihiro Fujieda, Shigeharu Sano, Kazuo Oncol Lett Articles The vascularized fibular flap is one of the standard treatment choices for the reconstruction of the mandible; however, the consequences of condylar restoration have not previously been reported. The use of three-dimensional models allows for a more predictable reconstruction. The purpose of the present study was to assess the outcome of stereolithographic model-assisted reconstruction of the mandibular condyle with a vascularized fibular flap. A total of 5 patients underwent mandibular resection including the condyle and immediate reconstruction with a vascularized fibular flap. A stereolithographic model was used to determine the length and angle of the bony reconstruction. In all patients, the temporomandibular joint (TMJ) disc was preserved, and the contoured fibular end was placed directly into the glenoid fossa under the TMJ disc. To investigate the morphological and functional outcomes, radiographic and clinical examinations were performed, and a food scale questionnaire was administered. The mean period of follow-up was 23 months, and all the flaps were viable. Cosmetic results were generally satisfactory. Radiographic assessment revealed that the end of the fibular graft became round-shaped. None of the patients had abnormal bone resorption, dislocation or ankylosis. The mean value of maximum mouth opening was 31 mm. No patients exhibited difficulties with occlusion. All patients recovered their ability to ingest nearly the same foods that were ingested prior to surgery. The stereolithographic model-assisted reconstruction of mandibular condyle with a vascularized fibular flap is therefore useful for morphological and functional reconstructions of the hemimandible, including condylar defects. D.A. Spandidos 2017-11 2017-09-07 /pmc/articles/PMC5656033/ /pubmed/29113176 http://dx.doi.org/10.3892/ol.2017.6909 Text en Copyright: © Yoshimura et al. This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License (https://creativecommons.org/licenses/by-nc-nd/4.0/) , which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.
spellingShingle Articles
Yoshimura, Hitoshi
Matsuda, Shinpei
Ohba, Seigo
Minegishi, Yoshiki
Nakai, Kunihiro
Fujieda, Shigeharu
Sano, Kazuo
Stereolithographic model-assisted reconstruction of the mandibular condyle with a vascularized fibular flap following hemimandibulectomy: Evaluation of morphological and functional outcomes
title Stereolithographic model-assisted reconstruction of the mandibular condyle with a vascularized fibular flap following hemimandibulectomy: Evaluation of morphological and functional outcomes
title_full Stereolithographic model-assisted reconstruction of the mandibular condyle with a vascularized fibular flap following hemimandibulectomy: Evaluation of morphological and functional outcomes
title_fullStr Stereolithographic model-assisted reconstruction of the mandibular condyle with a vascularized fibular flap following hemimandibulectomy: Evaluation of morphological and functional outcomes
title_full_unstemmed Stereolithographic model-assisted reconstruction of the mandibular condyle with a vascularized fibular flap following hemimandibulectomy: Evaluation of morphological and functional outcomes
title_short Stereolithographic model-assisted reconstruction of the mandibular condyle with a vascularized fibular flap following hemimandibulectomy: Evaluation of morphological and functional outcomes
title_sort stereolithographic model-assisted reconstruction of the mandibular condyle with a vascularized fibular flap following hemimandibulectomy: evaluation of morphological and functional outcomes
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5656033/
https://www.ncbi.nlm.nih.gov/pubmed/29113176
http://dx.doi.org/10.3892/ol.2017.6909
work_keys_str_mv AT yoshimurahitoshi stereolithographicmodelassistedreconstructionofthemandibularcondylewithavascularizedfibularflapfollowinghemimandibulectomyevaluationofmorphologicalandfunctionaloutcomes
AT matsudashinpei stereolithographicmodelassistedreconstructionofthemandibularcondylewithavascularizedfibularflapfollowinghemimandibulectomyevaluationofmorphologicalandfunctionaloutcomes
AT ohbaseigo stereolithographicmodelassistedreconstructionofthemandibularcondylewithavascularizedfibularflapfollowinghemimandibulectomyevaluationofmorphologicalandfunctionaloutcomes
AT minegishiyoshiki stereolithographicmodelassistedreconstructionofthemandibularcondylewithavascularizedfibularflapfollowinghemimandibulectomyevaluationofmorphologicalandfunctionaloutcomes
AT nakaikunihiro stereolithographicmodelassistedreconstructionofthemandibularcondylewithavascularizedfibularflapfollowinghemimandibulectomyevaluationofmorphologicalandfunctionaloutcomes
AT fujiedashigeharu stereolithographicmodelassistedreconstructionofthemandibularcondylewithavascularizedfibularflapfollowinghemimandibulectomyevaluationofmorphologicalandfunctionaloutcomes
AT sanokazuo stereolithographicmodelassistedreconstructionofthemandibularcondylewithavascularizedfibularflapfollowinghemimandibulectomyevaluationofmorphologicalandfunctionaloutcomes