Goldmann V Standard Automated Perimetry Underestimates Central Visual Sensitivity in Glaucomatous Eyes with Increased Axial Length

PURPOSE: To investigate the effect of axial length (AL) on the structure–function relationship between retinal nerve fiber layer (RNFL) thickness measurements and visual field (VF) sensitivity measured with Goldmann III and V. METHOD: There were 85 eyes of 85 patients with primary open angle glaucom...

Descripción completa

Detalles Bibliográficos
Autores principales: Yanagisawa, Mieko, Murata, Hiroshi, Matsuura, Masato, Fujino, Yuri, Hirasawa, Kazunori, Asaoka, Ryo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5656222/
https://www.ncbi.nlm.nih.gov/pubmed/29082108
http://dx.doi.org/10.1167/tvst.6.5.13
_version_ 1783273677056376832
author Yanagisawa, Mieko
Murata, Hiroshi
Matsuura, Masato
Fujino, Yuri
Hirasawa, Kazunori
Asaoka, Ryo
author_facet Yanagisawa, Mieko
Murata, Hiroshi
Matsuura, Masato
Fujino, Yuri
Hirasawa, Kazunori
Asaoka, Ryo
author_sort Yanagisawa, Mieko
collection PubMed
description PURPOSE: To investigate the effect of axial length (AL) on the structure–function relationship between retinal nerve fiber layer (RNFL) thickness measurements and visual field (VF) sensitivity measured with Goldmann III and V. METHOD: There were 85 eyes of 85 patients with primary open angle glaucoma included in the current study. Optical coherence tomography and VF (Humphrey Field Analyzer 24-2 or 30-2) measurements with Goldmann III and V targets were carried out in all patients. The optic disc and the VF were divided into six clusters and the relationship between circumpapillary RNFL (cpRNFL) thickness and VF sensitivity (with Goldmann III or V), age, and AL were investigated in each cluster. RESULT: Visual sensitivity with Goldmann III (19.3 ± 11.7 dB, mean ± standard deviation) was significantly lower than that with Goldmann V (24.6 ± 11.0 dB, P < 0.001, linear mixed model). Visual sensitivities with both Goldmann III and V were significantly correlated with cpRNFL thickness in all clusters. Visual sensitivity decreased with increasing AL in the nasal retinal area for both targets, however, this phenomenon was only observed with the Goldmann V target in the temporal area. CONCLUSION: Visual sensitivity measured with the size V target decreases with increasing AL in the temporal area, which corresponds to the papillomacular bundle. In the nasal retinal area, visual sensitivity decreases with the increase of AL for both Goldmann III and Goldmann V. TRANSLATIONAL RELEVANCE: Careful consideration is needed when measuring visual sensitivity using Goldmann V target in glaucomatous eyes with increased AL.
format Online
Article
Text
id pubmed-5656222
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-56562222017-10-27 Goldmann V Standard Automated Perimetry Underestimates Central Visual Sensitivity in Glaucomatous Eyes with Increased Axial Length Yanagisawa, Mieko Murata, Hiroshi Matsuura, Masato Fujino, Yuri Hirasawa, Kazunori Asaoka, Ryo Transl Vis Sci Technol Articles PURPOSE: To investigate the effect of axial length (AL) on the structure–function relationship between retinal nerve fiber layer (RNFL) thickness measurements and visual field (VF) sensitivity measured with Goldmann III and V. METHOD: There were 85 eyes of 85 patients with primary open angle glaucoma included in the current study. Optical coherence tomography and VF (Humphrey Field Analyzer 24-2 or 30-2) measurements with Goldmann III and V targets were carried out in all patients. The optic disc and the VF were divided into six clusters and the relationship between circumpapillary RNFL (cpRNFL) thickness and VF sensitivity (with Goldmann III or V), age, and AL were investigated in each cluster. RESULT: Visual sensitivity with Goldmann III (19.3 ± 11.7 dB, mean ± standard deviation) was significantly lower than that with Goldmann V (24.6 ± 11.0 dB, P < 0.001, linear mixed model). Visual sensitivities with both Goldmann III and V were significantly correlated with cpRNFL thickness in all clusters. Visual sensitivity decreased with increasing AL in the nasal retinal area for both targets, however, this phenomenon was only observed with the Goldmann V target in the temporal area. CONCLUSION: Visual sensitivity measured with the size V target decreases with increasing AL in the temporal area, which corresponds to the papillomacular bundle. In the nasal retinal area, visual sensitivity decreases with the increase of AL for both Goldmann III and Goldmann V. TRANSLATIONAL RELEVANCE: Careful consideration is needed when measuring visual sensitivity using Goldmann V target in glaucomatous eyes with increased AL. The Association for Research in Vision and Ophthalmology 2017-10-24 /pmc/articles/PMC5656222/ /pubmed/29082108 http://dx.doi.org/10.1167/tvst.6.5.13 Text en Copyright 2017 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
spellingShingle Articles
Yanagisawa, Mieko
Murata, Hiroshi
Matsuura, Masato
Fujino, Yuri
Hirasawa, Kazunori
Asaoka, Ryo
Goldmann V Standard Automated Perimetry Underestimates Central Visual Sensitivity in Glaucomatous Eyes with Increased Axial Length
title Goldmann V Standard Automated Perimetry Underestimates Central Visual Sensitivity in Glaucomatous Eyes with Increased Axial Length
title_full Goldmann V Standard Automated Perimetry Underestimates Central Visual Sensitivity in Glaucomatous Eyes with Increased Axial Length
title_fullStr Goldmann V Standard Automated Perimetry Underestimates Central Visual Sensitivity in Glaucomatous Eyes with Increased Axial Length
title_full_unstemmed Goldmann V Standard Automated Perimetry Underestimates Central Visual Sensitivity in Glaucomatous Eyes with Increased Axial Length
title_short Goldmann V Standard Automated Perimetry Underestimates Central Visual Sensitivity in Glaucomatous Eyes with Increased Axial Length
title_sort goldmann v standard automated perimetry underestimates central visual sensitivity in glaucomatous eyes with increased axial length
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5656222/
https://www.ncbi.nlm.nih.gov/pubmed/29082108
http://dx.doi.org/10.1167/tvst.6.5.13
work_keys_str_mv AT yanagisawamieko goldmannvstandardautomatedperimetryunderestimatescentralvisualsensitivityinglaucomatouseyeswithincreasedaxiallength
AT muratahiroshi goldmannvstandardautomatedperimetryunderestimatescentralvisualsensitivityinglaucomatouseyeswithincreasedaxiallength
AT matsuuramasato goldmannvstandardautomatedperimetryunderestimatescentralvisualsensitivityinglaucomatouseyeswithincreasedaxiallength
AT fujinoyuri goldmannvstandardautomatedperimetryunderestimatescentralvisualsensitivityinglaucomatouseyeswithincreasedaxiallength
AT hirasawakazunori goldmannvstandardautomatedperimetryunderestimatescentralvisualsensitivityinglaucomatouseyeswithincreasedaxiallength
AT asaokaryo goldmannvstandardautomatedperimetryunderestimatescentralvisualsensitivityinglaucomatouseyeswithincreasedaxiallength