Cargando…

Osseointegration of layer-by-layer polyelectrolyte multilayers loaded with IGF1 and coated on titanium implant under osteoporotic condition

PURPOSE: Titanium implant is a widely used method for dental prosthesis restoration. Nevertheless, in patients with systemic diseases, including osteoporosis, diabetes, and cancer, the success rate of the implant is greatly reduced. This study investigates a new implant material loaded with insulin-...

Descripción completa

Detalles Bibliográficos
Autores principales: Xing, Helin, Wang, Xing, Xiao, Saisong, Zhang, Guilan, Li, Meng, Wang, Peihuan, Shi, Quan, Qiao, Pengyan, E, Lingling, Liu, Hongchen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5656347/
https://www.ncbi.nlm.nih.gov/pubmed/29089765
http://dx.doi.org/10.2147/IJN.S148001
_version_ 1783273690909114368
author Xing, Helin
Wang, Xing
Xiao, Saisong
Zhang, Guilan
Li, Meng
Wang, Peihuan
Shi, Quan
Qiao, Pengyan
E, Lingling
Liu, Hongchen
author_facet Xing, Helin
Wang, Xing
Xiao, Saisong
Zhang, Guilan
Li, Meng
Wang, Peihuan
Shi, Quan
Qiao, Pengyan
E, Lingling
Liu, Hongchen
author_sort Xing, Helin
collection PubMed
description PURPOSE: Titanium implant is a widely used method for dental prosthesis restoration. Nevertheless, in patients with systemic diseases, including osteoporosis, diabetes, and cancer, the success rate of the implant is greatly reduced. This study investigates a new implant material loaded with insulin-like growth factor 1 (IGF1), which could potentially improve the implant success rate, accelerate the occurrence of osseointegration, and provide a new strategy for implant treatment in osteoporotic patients. MATERIALS AND METHODS: Biofunctionalized polyelectrolyte multilayers (PEMs) with polyethylenimine as the excitation layer and gelatin/chitosan loaded with IGF1 were prepared on the surface of titanium implant by layer-by-layer self-assembly technique. The physical and chemical properties of the biofunctionalized PEMs, the biological characteristics of bone marrow mesenchymal stem cells (BMMSCs), and bone implant contact correlation test indexes were detected and analyzed in vitro and in vivo using osteoporosis rat model. RESULTS: PEMs coatings loaded with IGF1 (TNS-PEM-IGF1-100) implant promoted the early stage of BMMSCs adhesion. Under the action of body fluids, the active coating showed sustained release of growth factors, which in turn promoted the proliferation and differentiation of BMMSCs and the extracellular matrix. At 8 weeks from implant surgery, the new bone around the implants was examined using micro-CT and acid fuchsin/methylene blue staining. The new bone formation increased with time in each group, while the TNS-PEM-IGF1-100 group showed the highest thickness and continuity. CONCLUSION: TNS-PEM-IGF1-100 new implants can promote osseointegration in osteoporotic conditions both in vivo and in vitro and provide a new strategy for implant repair in osteoporotic patients.
format Online
Article
Text
id pubmed-5656347
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-56563472017-10-31 Osseointegration of layer-by-layer polyelectrolyte multilayers loaded with IGF1 and coated on titanium implant under osteoporotic condition Xing, Helin Wang, Xing Xiao, Saisong Zhang, Guilan Li, Meng Wang, Peihuan Shi, Quan Qiao, Pengyan E, Lingling Liu, Hongchen Int J Nanomedicine Original Research PURPOSE: Titanium implant is a widely used method for dental prosthesis restoration. Nevertheless, in patients with systemic diseases, including osteoporosis, diabetes, and cancer, the success rate of the implant is greatly reduced. This study investigates a new implant material loaded with insulin-like growth factor 1 (IGF1), which could potentially improve the implant success rate, accelerate the occurrence of osseointegration, and provide a new strategy for implant treatment in osteoporotic patients. MATERIALS AND METHODS: Biofunctionalized polyelectrolyte multilayers (PEMs) with polyethylenimine as the excitation layer and gelatin/chitosan loaded with IGF1 were prepared on the surface of titanium implant by layer-by-layer self-assembly technique. The physical and chemical properties of the biofunctionalized PEMs, the biological characteristics of bone marrow mesenchymal stem cells (BMMSCs), and bone implant contact correlation test indexes were detected and analyzed in vitro and in vivo using osteoporosis rat model. RESULTS: PEMs coatings loaded with IGF1 (TNS-PEM-IGF1-100) implant promoted the early stage of BMMSCs adhesion. Under the action of body fluids, the active coating showed sustained release of growth factors, which in turn promoted the proliferation and differentiation of BMMSCs and the extracellular matrix. At 8 weeks from implant surgery, the new bone around the implants was examined using micro-CT and acid fuchsin/methylene blue staining. The new bone formation increased with time in each group, while the TNS-PEM-IGF1-100 group showed the highest thickness and continuity. CONCLUSION: TNS-PEM-IGF1-100 new implants can promote osseointegration in osteoporotic conditions both in vivo and in vitro and provide a new strategy for implant repair in osteoporotic patients. Dove Medical Press 2017-10-19 /pmc/articles/PMC5656347/ /pubmed/29089765 http://dx.doi.org/10.2147/IJN.S148001 Text en © 2017 Xing et al. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.
spellingShingle Original Research
Xing, Helin
Wang, Xing
Xiao, Saisong
Zhang, Guilan
Li, Meng
Wang, Peihuan
Shi, Quan
Qiao, Pengyan
E, Lingling
Liu, Hongchen
Osseointegration of layer-by-layer polyelectrolyte multilayers loaded with IGF1 and coated on titanium implant under osteoporotic condition
title Osseointegration of layer-by-layer polyelectrolyte multilayers loaded with IGF1 and coated on titanium implant under osteoporotic condition
title_full Osseointegration of layer-by-layer polyelectrolyte multilayers loaded with IGF1 and coated on titanium implant under osteoporotic condition
title_fullStr Osseointegration of layer-by-layer polyelectrolyte multilayers loaded with IGF1 and coated on titanium implant under osteoporotic condition
title_full_unstemmed Osseointegration of layer-by-layer polyelectrolyte multilayers loaded with IGF1 and coated on titanium implant under osteoporotic condition
title_short Osseointegration of layer-by-layer polyelectrolyte multilayers loaded with IGF1 and coated on titanium implant under osteoporotic condition
title_sort osseointegration of layer-by-layer polyelectrolyte multilayers loaded with igf1 and coated on titanium implant under osteoporotic condition
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5656347/
https://www.ncbi.nlm.nih.gov/pubmed/29089765
http://dx.doi.org/10.2147/IJN.S148001
work_keys_str_mv AT xinghelin osseointegrationoflayerbylayerpolyelectrolytemultilayersloadedwithigf1andcoatedontitaniumimplantunderosteoporoticcondition
AT wangxing osseointegrationoflayerbylayerpolyelectrolytemultilayersloadedwithigf1andcoatedontitaniumimplantunderosteoporoticcondition
AT xiaosaisong osseointegrationoflayerbylayerpolyelectrolytemultilayersloadedwithigf1andcoatedontitaniumimplantunderosteoporoticcondition
AT zhangguilan osseointegrationoflayerbylayerpolyelectrolytemultilayersloadedwithigf1andcoatedontitaniumimplantunderosteoporoticcondition
AT limeng osseointegrationoflayerbylayerpolyelectrolytemultilayersloadedwithigf1andcoatedontitaniumimplantunderosteoporoticcondition
AT wangpeihuan osseointegrationoflayerbylayerpolyelectrolytemultilayersloadedwithigf1andcoatedontitaniumimplantunderosteoporoticcondition
AT shiquan osseointegrationoflayerbylayerpolyelectrolytemultilayersloadedwithigf1andcoatedontitaniumimplantunderosteoporoticcondition
AT qiaopengyan osseointegrationoflayerbylayerpolyelectrolytemultilayersloadedwithigf1andcoatedontitaniumimplantunderosteoporoticcondition
AT elingling osseointegrationoflayerbylayerpolyelectrolytemultilayersloadedwithigf1andcoatedontitaniumimplantunderosteoporoticcondition
AT liuhongchen osseointegrationoflayerbylayerpolyelectrolytemultilayersloadedwithigf1andcoatedontitaniumimplantunderosteoporoticcondition