Europium (III) chelate microparticle-based lateral flow immunoassay strips for rapid and quantitative detection of antibody to hepatitis B core antigen

Quantitative hepatitis B core antigen (anti-HBc) measurements could play an important role in evaluating therapeutic outcomes and optimizing the antiviral therapy of chronic hepatitis B infection. In this study, we have developed a simple and rapid fluorescence point-of-care test based on a lateral...

Descripción completa

Detalles Bibliográficos
Autores principales: Liang, Rong-Liang, Deng, Qiao-Ting, Chen, Zhen-Hua, Xu, Xu-Ping, Zhou, Jian-Wei, Liang, Jun-Yu, Dong, Zhi-Ning, Liu, Tian-Cai, Wu, Ying-Song
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5658374/
https://www.ncbi.nlm.nih.gov/pubmed/29074971
http://dx.doi.org/10.1038/s41598-017-14427-4
_version_ 1783273982033657856
author Liang, Rong-Liang
Deng, Qiao-Ting
Chen, Zhen-Hua
Xu, Xu-Ping
Zhou, Jian-Wei
Liang, Jun-Yu
Dong, Zhi-Ning
Liu, Tian-Cai
Wu, Ying-Song
author_facet Liang, Rong-Liang
Deng, Qiao-Ting
Chen, Zhen-Hua
Xu, Xu-Ping
Zhou, Jian-Wei
Liang, Jun-Yu
Dong, Zhi-Ning
Liu, Tian-Cai
Wu, Ying-Song
author_sort Liang, Rong-Liang
collection PubMed
description Quantitative hepatitis B core antigen (anti-HBc) measurements could play an important role in evaluating therapeutic outcomes and optimizing the antiviral therapy of chronic hepatitis B infection. In this study, we have developed a simple and rapid fluorescence point-of-care test based on a lateral flow immunoassay (LFIA) method integrated with Eu (III) chelate microparticles to quantitatively determine anti-HBc concentrations in serum. This assay is based on a direct competitive immunoassay performed on lateral flow test strips with an assay time of 15 min. The Eu (III) chelate microparticle-based LFIA assay could quantitatively detect anti-HBc levels with a limit of detection of 0.31 IU mL(−1), and exhibited a wide linear range (0.63–640 IU mL(−1)). The intra- and inter-assay coefficients of variation for anti-HBc were both less than 10% and a satisfactory dilution test and accuracy were demonstrated. There were no statistically significant differences in sensitivity or specificity in serum samples between the Eu (III) chelate microparticle-based LFIA strips and the Abbott Architect kit. A simple, rapid and effective quantitative detection of anti-HBc was possible using the Eu (III) chelate microparticle-based LFIA strips. The strips will provide diagnostic value for clinical application.
format Online
Article
Text
id pubmed-5658374
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-56583742017-10-31 Europium (III) chelate microparticle-based lateral flow immunoassay strips for rapid and quantitative detection of antibody to hepatitis B core antigen Liang, Rong-Liang Deng, Qiao-Ting Chen, Zhen-Hua Xu, Xu-Ping Zhou, Jian-Wei Liang, Jun-Yu Dong, Zhi-Ning Liu, Tian-Cai Wu, Ying-Song Sci Rep Article Quantitative hepatitis B core antigen (anti-HBc) measurements could play an important role in evaluating therapeutic outcomes and optimizing the antiviral therapy of chronic hepatitis B infection. In this study, we have developed a simple and rapid fluorescence point-of-care test based on a lateral flow immunoassay (LFIA) method integrated with Eu (III) chelate microparticles to quantitatively determine anti-HBc concentrations in serum. This assay is based on a direct competitive immunoassay performed on lateral flow test strips with an assay time of 15 min. The Eu (III) chelate microparticle-based LFIA assay could quantitatively detect anti-HBc levels with a limit of detection of 0.31 IU mL(−1), and exhibited a wide linear range (0.63–640 IU mL(−1)). The intra- and inter-assay coefficients of variation for anti-HBc were both less than 10% and a satisfactory dilution test and accuracy were demonstrated. There were no statistically significant differences in sensitivity or specificity in serum samples between the Eu (III) chelate microparticle-based LFIA strips and the Abbott Architect kit. A simple, rapid and effective quantitative detection of anti-HBc was possible using the Eu (III) chelate microparticle-based LFIA strips. The strips will provide diagnostic value for clinical application. Nature Publishing Group UK 2017-10-26 /pmc/articles/PMC5658374/ /pubmed/29074971 http://dx.doi.org/10.1038/s41598-017-14427-4 Text en © The Author(s) 2017 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Liang, Rong-Liang
Deng, Qiao-Ting
Chen, Zhen-Hua
Xu, Xu-Ping
Zhou, Jian-Wei
Liang, Jun-Yu
Dong, Zhi-Ning
Liu, Tian-Cai
Wu, Ying-Song
Europium (III) chelate microparticle-based lateral flow immunoassay strips for rapid and quantitative detection of antibody to hepatitis B core antigen
title Europium (III) chelate microparticle-based lateral flow immunoassay strips for rapid and quantitative detection of antibody to hepatitis B core antigen
title_full Europium (III) chelate microparticle-based lateral flow immunoassay strips for rapid and quantitative detection of antibody to hepatitis B core antigen
title_fullStr Europium (III) chelate microparticle-based lateral flow immunoassay strips for rapid and quantitative detection of antibody to hepatitis B core antigen
title_full_unstemmed Europium (III) chelate microparticle-based lateral flow immunoassay strips for rapid and quantitative detection of antibody to hepatitis B core antigen
title_short Europium (III) chelate microparticle-based lateral flow immunoassay strips for rapid and quantitative detection of antibody to hepatitis B core antigen
title_sort europium (iii) chelate microparticle-based lateral flow immunoassay strips for rapid and quantitative detection of antibody to hepatitis b core antigen
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5658374/
https://www.ncbi.nlm.nih.gov/pubmed/29074971
http://dx.doi.org/10.1038/s41598-017-14427-4
work_keys_str_mv AT liangrongliang europiumiiichelatemicroparticlebasedlateralflowimmunoassaystripsforrapidandquantitativedetectionofantibodytohepatitisbcoreantigen
AT dengqiaoting europiumiiichelatemicroparticlebasedlateralflowimmunoassaystripsforrapidandquantitativedetectionofantibodytohepatitisbcoreantigen
AT chenzhenhua europiumiiichelatemicroparticlebasedlateralflowimmunoassaystripsforrapidandquantitativedetectionofantibodytohepatitisbcoreantigen
AT xuxuping europiumiiichelatemicroparticlebasedlateralflowimmunoassaystripsforrapidandquantitativedetectionofantibodytohepatitisbcoreantigen
AT zhoujianwei europiumiiichelatemicroparticlebasedlateralflowimmunoassaystripsforrapidandquantitativedetectionofantibodytohepatitisbcoreantigen
AT liangjunyu europiumiiichelatemicroparticlebasedlateralflowimmunoassaystripsforrapidandquantitativedetectionofantibodytohepatitisbcoreantigen
AT dongzhining europiumiiichelatemicroparticlebasedlateralflowimmunoassaystripsforrapidandquantitativedetectionofantibodytohepatitisbcoreantigen
AT liutiancai europiumiiichelatemicroparticlebasedlateralflowimmunoassaystripsforrapidandquantitativedetectionofantibodytohepatitisbcoreantigen
AT wuyingsong europiumiiichelatemicroparticlebasedlateralflowimmunoassaystripsforrapidandquantitativedetectionofantibodytohepatitisbcoreantigen