Uterine artery blood flow and microvessel density by vaginal color Doppler ultrasonography in embryo implantation failure

The purpose of this study was to investigate the clinical application of uterine artery blood flow parameters by vaginal color Doppler ultrasonography in patients with repeated embryo implantation failure and to examine the correlation between uterine artery blood flow parameters and microvessel den...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Zhen, Wang, Xingling, Guan, Yichun, Yu, Xiaona, Liu, Jing, Zhang, Zhan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: D.A. Spandidos 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5658763/
https://www.ncbi.nlm.nih.gov/pubmed/29104668
http://dx.doi.org/10.3892/etm.2017.5114
_version_ 1783274069067563008
author Li, Zhen
Wang, Xingling
Guan, Yichun
Yu, Xiaona
Liu, Jing
Zhang, Zhan
author_facet Li, Zhen
Wang, Xingling
Guan, Yichun
Yu, Xiaona
Liu, Jing
Zhang, Zhan
author_sort Li, Zhen
collection PubMed
description The purpose of this study was to investigate the clinical application of uterine artery blood flow parameters by vaginal color Doppler ultrasonography in patients with repeated embryo implantation failure and to examine the correlation between uterine artery blood flow parameters and microvessel density (MVD). We monitored the outcomes of in vitro fertilization and embryo transfer in eighty patients. We divided the patients into two groups: Pregnancy (successful pregnancy, n=50) and repeated implantation failure (more than two failures of in vitro fertilization-embryo transfer, n=30). The patients were subjected to vaginal color Doppler ultrasonography to measure endometrial thickness, peak systolic velocity/end diastolic velocity (S/D), pulsatility index (PI), resistance index (RI), and other uterine artery blood flow parameters. We found no significant differences in endometrial thickness (human chorionic gonadotropin endometrial thickness) and uterine artery blood flow parameters (S/D, PI) between the two groups. The RI value of endometrial blood flow was significantly higher in the repeated implantation failure group than that in pregnancy group. The endometrium MVD in the repeated implantation failure group was significantly lower than that of the pregnancy group. Spearman correlation analysis showed that S/D value of uterine artery blood flow in repeated implantation failure group was not correlated with MVD or uterine artery blood flow PI, but was positively correlated with RI. Endometrium MVD in patients with repeated implantation failure was significantly lower than that in patients with successful pregnancy during the implantation window. We also found a significant difference in uterine artery blood flow RI between the two groups. The uterine artery blood flow RI in patients with repeated implantation failure was positively correlated with MVD, which has clinical significance in predicting the outcome of embryo transfer.
format Online
Article
Text
id pubmed-5658763
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher D.A. Spandidos
record_format MEDLINE/PubMed
spelling pubmed-56587632017-11-04 Uterine artery blood flow and microvessel density by vaginal color Doppler ultrasonography in embryo implantation failure Li, Zhen Wang, Xingling Guan, Yichun Yu, Xiaona Liu, Jing Zhang, Zhan Exp Ther Med Articles The purpose of this study was to investigate the clinical application of uterine artery blood flow parameters by vaginal color Doppler ultrasonography in patients with repeated embryo implantation failure and to examine the correlation between uterine artery blood flow parameters and microvessel density (MVD). We monitored the outcomes of in vitro fertilization and embryo transfer in eighty patients. We divided the patients into two groups: Pregnancy (successful pregnancy, n=50) and repeated implantation failure (more than two failures of in vitro fertilization-embryo transfer, n=30). The patients were subjected to vaginal color Doppler ultrasonography to measure endometrial thickness, peak systolic velocity/end diastolic velocity (S/D), pulsatility index (PI), resistance index (RI), and other uterine artery blood flow parameters. We found no significant differences in endometrial thickness (human chorionic gonadotropin endometrial thickness) and uterine artery blood flow parameters (S/D, PI) between the two groups. The RI value of endometrial blood flow was significantly higher in the repeated implantation failure group than that in pregnancy group. The endometrium MVD in the repeated implantation failure group was significantly lower than that of the pregnancy group. Spearman correlation analysis showed that S/D value of uterine artery blood flow in repeated implantation failure group was not correlated with MVD or uterine artery blood flow PI, but was positively correlated with RI. Endometrium MVD in patients with repeated implantation failure was significantly lower than that in patients with successful pregnancy during the implantation window. We also found a significant difference in uterine artery blood flow RI between the two groups. The uterine artery blood flow RI in patients with repeated implantation failure was positively correlated with MVD, which has clinical significance in predicting the outcome of embryo transfer. D.A. Spandidos 2017-11 2017-09-08 /pmc/articles/PMC5658763/ /pubmed/29104668 http://dx.doi.org/10.3892/etm.2017.5114 Text en Copyright: © Li et al. This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License (https://creativecommons.org/licenses/by-nc-nd/4.0/) , which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.
spellingShingle Articles
Li, Zhen
Wang, Xingling
Guan, Yichun
Yu, Xiaona
Liu, Jing
Zhang, Zhan
Uterine artery blood flow and microvessel density by vaginal color Doppler ultrasonography in embryo implantation failure
title Uterine artery blood flow and microvessel density by vaginal color Doppler ultrasonography in embryo implantation failure
title_full Uterine artery blood flow and microvessel density by vaginal color Doppler ultrasonography in embryo implantation failure
title_fullStr Uterine artery blood flow and microvessel density by vaginal color Doppler ultrasonography in embryo implantation failure
title_full_unstemmed Uterine artery blood flow and microvessel density by vaginal color Doppler ultrasonography in embryo implantation failure
title_short Uterine artery blood flow and microvessel density by vaginal color Doppler ultrasonography in embryo implantation failure
title_sort uterine artery blood flow and microvessel density by vaginal color doppler ultrasonography in embryo implantation failure
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5658763/
https://www.ncbi.nlm.nih.gov/pubmed/29104668
http://dx.doi.org/10.3892/etm.2017.5114
work_keys_str_mv AT lizhen uterinearterybloodflowandmicrovesseldensitybyvaginalcolordopplerultrasonographyinembryoimplantationfailure
AT wangxingling uterinearterybloodflowandmicrovesseldensitybyvaginalcolordopplerultrasonographyinembryoimplantationfailure
AT guanyichun uterinearterybloodflowandmicrovesseldensitybyvaginalcolordopplerultrasonographyinembryoimplantationfailure
AT yuxiaona uterinearterybloodflowandmicrovesseldensitybyvaginalcolordopplerultrasonographyinembryoimplantationfailure
AT liujing uterinearterybloodflowandmicrovesseldensitybyvaginalcolordopplerultrasonographyinembryoimplantationfailure
AT zhangzhan uterinearterybloodflowandmicrovesseldensitybyvaginalcolordopplerultrasonographyinembryoimplantationfailure