A cross-sectional study of the temporal evolution of electricity consumption of six commercial buildings

Current approaches to building efficiency diagnoses include conventional energy audit techniques that can be expensive and time consuming. In contrast, virtual energy audits of readily available 15-minute-interval building electricity consumption are being explored to provide quick, inexpensive, and...

Descripción completa

Detalles Bibliográficos
Autores principales: Pickering, Ethan M., Hossain, Mohammad A., Mousseau, Jack P., Swanson, Rachel A., French, Roger H., Abramson, Alexis R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5663429/
https://www.ncbi.nlm.nih.gov/pubmed/29088269
http://dx.doi.org/10.1371/journal.pone.0187129
_version_ 1783274810176962560
author Pickering, Ethan M.
Hossain, Mohammad A.
Mousseau, Jack P.
Swanson, Rachel A.
French, Roger H.
Abramson, Alexis R.
author_facet Pickering, Ethan M.
Hossain, Mohammad A.
Mousseau, Jack P.
Swanson, Rachel A.
French, Roger H.
Abramson, Alexis R.
author_sort Pickering, Ethan M.
collection PubMed
description Current approaches to building efficiency diagnoses include conventional energy audit techniques that can be expensive and time consuming. In contrast, virtual energy audits of readily available 15-minute-interval building electricity consumption are being explored to provide quick, inexpensive, and useful insights into building operation characteristics. A cross sectional analysis of six buildings in two different climate zones provides methods for data cleaning, population-based building comparisons, and relationships (correlations) of weather and electricity consumption. Data cleaning methods have been developed to categorize and appropriately filter or correct anomalous data including outliers, missing data, and erroneous values (resulting in < 0.5% anomalies). The utility of a cross-sectional analysis of a sample set of building’s electricity consumption is found through comparisons of baseload, daily consumption variance, and energy use intensity. Correlations of weather and electricity consumption 15-minute interval datasets show important relationships for the heating and cooling seasons using computed correlations of a Time-Specific-Averaged-Ordered Variable (exterior temperature) and corresponding averaged variables (electricity consumption)(TSAOV method). The TSAOV method is unique as it introduces time of day as a third variable while also minimizing randomness in both correlated variables through averaging. This study found that many of the pair-wise linear correlation analyses lacked strong relationships, prompting the development of the new TSAOV method to uncover the causal relationship between electricity and weather. We conclude that a combination of varied HVAC system operations, building thermal mass, plug load use, and building set point temperatures are likely responsible for the poor correlations in the prior studies, while the correlation of time-specific-averaged-ordered temperature and corresponding averaged variables method developed herein adequately accounts for these issues and enables discovery of strong linear pair-wise correlation R values. TSAOV correlations lay the foundation for a new approach to building studies, that mitigates plug load interferences and identifies more accurate insights into weather-energy relationship for all building types. Over all six buildings analyzed the TSAOV method reported very significant average correlations per building of 0.94 to 0.82 in magnitude. Our rigorous statistics-based methods applied to 15-minute-interval electricity data further enables virtual energy audits of buildings to quickly and inexpensively inform energy savings measures.
format Online
Article
Text
id pubmed-5663429
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-56634292017-11-09 A cross-sectional study of the temporal evolution of electricity consumption of six commercial buildings Pickering, Ethan M. Hossain, Mohammad A. Mousseau, Jack P. Swanson, Rachel A. French, Roger H. Abramson, Alexis R. PLoS One Research Article Current approaches to building efficiency diagnoses include conventional energy audit techniques that can be expensive and time consuming. In contrast, virtual energy audits of readily available 15-minute-interval building electricity consumption are being explored to provide quick, inexpensive, and useful insights into building operation characteristics. A cross sectional analysis of six buildings in two different climate zones provides methods for data cleaning, population-based building comparisons, and relationships (correlations) of weather and electricity consumption. Data cleaning methods have been developed to categorize and appropriately filter or correct anomalous data including outliers, missing data, and erroneous values (resulting in < 0.5% anomalies). The utility of a cross-sectional analysis of a sample set of building’s electricity consumption is found through comparisons of baseload, daily consumption variance, and energy use intensity. Correlations of weather and electricity consumption 15-minute interval datasets show important relationships for the heating and cooling seasons using computed correlations of a Time-Specific-Averaged-Ordered Variable (exterior temperature) and corresponding averaged variables (electricity consumption)(TSAOV method). The TSAOV method is unique as it introduces time of day as a third variable while also minimizing randomness in both correlated variables through averaging. This study found that many of the pair-wise linear correlation analyses lacked strong relationships, prompting the development of the new TSAOV method to uncover the causal relationship between electricity and weather. We conclude that a combination of varied HVAC system operations, building thermal mass, plug load use, and building set point temperatures are likely responsible for the poor correlations in the prior studies, while the correlation of time-specific-averaged-ordered temperature and corresponding averaged variables method developed herein adequately accounts for these issues and enables discovery of strong linear pair-wise correlation R values. TSAOV correlations lay the foundation for a new approach to building studies, that mitigates plug load interferences and identifies more accurate insights into weather-energy relationship for all building types. Over all six buildings analyzed the TSAOV method reported very significant average correlations per building of 0.94 to 0.82 in magnitude. Our rigorous statistics-based methods applied to 15-minute-interval electricity data further enables virtual energy audits of buildings to quickly and inexpensively inform energy savings measures. Public Library of Science 2017-10-31 /pmc/articles/PMC5663429/ /pubmed/29088269 http://dx.doi.org/10.1371/journal.pone.0187129 Text en © 2017 Pickering et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Pickering, Ethan M.
Hossain, Mohammad A.
Mousseau, Jack P.
Swanson, Rachel A.
French, Roger H.
Abramson, Alexis R.
A cross-sectional study of the temporal evolution of electricity consumption of six commercial buildings
title A cross-sectional study of the temporal evolution of electricity consumption of six commercial buildings
title_full A cross-sectional study of the temporal evolution of electricity consumption of six commercial buildings
title_fullStr A cross-sectional study of the temporal evolution of electricity consumption of six commercial buildings
title_full_unstemmed A cross-sectional study of the temporal evolution of electricity consumption of six commercial buildings
title_short A cross-sectional study of the temporal evolution of electricity consumption of six commercial buildings
title_sort cross-sectional study of the temporal evolution of electricity consumption of six commercial buildings
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5663429/
https://www.ncbi.nlm.nih.gov/pubmed/29088269
http://dx.doi.org/10.1371/journal.pone.0187129
work_keys_str_mv AT pickeringethanm acrosssectionalstudyofthetemporalevolutionofelectricityconsumptionofsixcommercialbuildings
AT hossainmohammada acrosssectionalstudyofthetemporalevolutionofelectricityconsumptionofsixcommercialbuildings
AT mousseaujackp acrosssectionalstudyofthetemporalevolutionofelectricityconsumptionofsixcommercialbuildings
AT swansonrachela acrosssectionalstudyofthetemporalevolutionofelectricityconsumptionofsixcommercialbuildings
AT frenchrogerh acrosssectionalstudyofthetemporalevolutionofelectricityconsumptionofsixcommercialbuildings
AT abramsonalexisr acrosssectionalstudyofthetemporalevolutionofelectricityconsumptionofsixcommercialbuildings
AT pickeringethanm crosssectionalstudyofthetemporalevolutionofelectricityconsumptionofsixcommercialbuildings
AT hossainmohammada crosssectionalstudyofthetemporalevolutionofelectricityconsumptionofsixcommercialbuildings
AT mousseaujackp crosssectionalstudyofthetemporalevolutionofelectricityconsumptionofsixcommercialbuildings
AT swansonrachela crosssectionalstudyofthetemporalevolutionofelectricityconsumptionofsixcommercialbuildings
AT frenchrogerh crosssectionalstudyofthetemporalevolutionofelectricityconsumptionofsixcommercialbuildings
AT abramsonalexisr crosssectionalstudyofthetemporalevolutionofelectricityconsumptionofsixcommercialbuildings