Cargando…
Study on the Shielding Effectiveness of an Arc Thermal Metal Spraying Method against an Electromagnetic Pulse
An electromagnetic pulse (EMP) explodes in real-time and causes critical damage within a short period to not only electric devices, but also to national infrastructures. In terms of EMP shielding rooms, metal plate has been used due to its excellent shielding effectiveness (SE). However, it has diff...
Autores principales: | Lee, Han-Seung, Choe, Hong-Bok, Baek, In-Young, Singh, Jitendra Kumar, Ismail, Mohamed A. |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5666961/ https://www.ncbi.nlm.nih.gov/pubmed/28976931 http://dx.doi.org/10.3390/ma10101155 |
Ejemplares similares
-
Electromagnetic Shielding Performance of Different Metallic Coatings Deposited by Arc Thermal Spray Process
por: Jang, Jong-Min, et al.
Publicado: (2020) -
Effects of Surface Treatment Conditions on the Bonding Strength and Electromagnetic Pulse Shielding of Concrete Using the 85Zn-15Al Arc Thermal Metal Spraying Method
por: Jang, Jongmin, et al.
Publicado: (2023) -
Electromagnetic Shielding Performance of Carbon Black Mixed Concrete with Zn–Al Metal Thermal Spray Coating
por: Lee, Han-Seung, et al.
Publicado: (2020) -
Experimental Study on the Electrochemical Anti-Corrosion Properties of Steel Structures Applying the Arc Thermal Metal Spraying Method
por: Choe, Hong-Bok, et al.
Publicado: (2014) -
Protection of Reinforced Concrete Structures of Waste Water Treatment Reservoirs with Stainless Steel Coating Using Arc Thermal Spraying Technique in Acidified Water
por: Lee, Han-Seung, et al.
Publicado: (2016)